5 resultados para INTRAORAL RADIOGRAPHY

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To date the hospital radiological workflow is completing a transition from analog to digital technology. Since the X-rays digital detection technologies have become mature, hospitals are trading on the natural devices turnover to replace the conventional screen film devices with digital ones. The transition process is complex and involves not just the equipment replacement but also new arrangements for image transmission, display (and reporting) and storage. This work is focused on 2D digital detector’s characterization with a concern to specific clinical application; the systems features linked to the image quality are analyzed to assess the clinical performances, the conversion efficiency, and the minimum dose necessary to get an acceptable image. The first section overviews the digital detector technologies focusing on the recent and promising technological developments. The second section contains a description of the characterization methods considered in this thesis categorized in physical, psychophysical and clinical; theory, models and procedures are described as well. The third section contains a set of characterizations performed on new equipments that appears to be some of the most advanced technologies available to date. The fourth section deals with some procedures and schemes employed for quality assurance programs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new multi-energy CT for small animals is being developed at the Physics Department of the University of Bologna, Italy. The system makes use of a set of quasi-monochromatic X-ray beams, with energy tunable in a range from 26 KeV to 72 KeV. These beams are produced by Bragg diffraction on a Highly Oriented Pyrolytic Graphite crystal. With quasi-monochromatic sources it is possible to perform multi-energy investigation in a more effective way, as compared with conventional X-ray tubes. Multi-energy techniques allow extracting physical information from the materials, such as effective atomic number, mass-thickness, density, that can be used to distinguish and quantitatively characterize the irradiated tissues. The aim of the system is the investigation and the development of new pre-clinic methods for the early detection of the tumors in small animals. An innovative technique, the Triple-Energy Radiography with Contrast Medium (TER), has been successfully implemented on our system. TER consist in combining a set of three quasi-monochromatic images of an object, in order to obtain a corresponding set of three single-tissue images, which are the mass-thickness map of three reference materials. TER can be applied to the quantitative mass-thickness-map reconstruction of a contrast medium, because it is able to remove completely the signal due to other tissues (i.e. the structural background noise). The technique is very sensitive to the contrast medium and is insensitive to the superposition of different materials. The method is a good candidate to the early detection of the tumor angiogenesis in mice. In this work we describe the tomographic system, with a particular focus on the quasi-monochromatic source. Moreover the TER method is presented with some preliminary results about small animal imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultrasonography (US) is an essential imaging tool for identifying abnormalities of the liver parenchyma, biliary tract and vascular system. US has replaced radiography as the initial imaging procedure in screening for liver disease in small animals. There are few reports of the use of conventional and helical computed tomography (CT) to assess canine or feline parenchymal and neoplastic liver disease and biliary disorders. In human medicine the development of multidetector- row helical computed tomography (MDCT), with its superior spatial and temporal resolution, has resulted in improved detection and characterization of diffuse and focal liver lesions. The increased availability of MDCT in veterinary practice provides incentive to develop MDCT protocols for liver imaging in small animals. The purpose of this study is to assess the rule of MDCT in the characterization of hepatobiliary diseases in small animals; and to compare this method with conventional US. Candidates for this prospective study were 175 consecutive patients (dogs and cats) referred for evaluation of hepatobiliary disease. The patients underwent liver US and MDCT. Percutaneous needle biopsy was performed on all liver lesions or alterations encountered. As for gallbladder, histopatological evaluation was obtained from cholecystectomy specimens. Ultrasonographic findings in this study agreed well with those of previous reports. A protocol for dual-phase liver MDCT in small animals has been described. MDCT findings in parenchymal disorders of the liver, hepatic neoplasia and biliary disorders are here first described in dogs and cats and compared with the corresponding features in human medicine. The ability of MDCT in detection and characterization of hepatobiliary diseases in small animals is overall superior to conventional US. Ultrasonography and MDCT scanning, however, play complementary rules in the evaluation of these diseases. Many conditions have distinctive imaging features that may permit diagnosis. In most instances biopsy is required for definitive diagnosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La sindrome di Noonan (SN) è una patologia a trasmissione autosomica dominante caratterizzata da bassa statura, difetti cardiaci congeniti, dismorfia facciale. In letteratura sono stati pubblicati pochi case reports riguardanti le condizioni orali-facciali in pazienti affetti da SN. Obiettivo. Individuare patologie di pertinenza ortopedico-ortodontica caratteristiche della sindrome utilizzando un campione di pazienti con diagnosi di SN. Metodi. Un gruppo di 10 pazienti affetti da SN è stato sottoposto a esame obiettivo extraorale ed intraorale, ortopantomografia, teleradiografia latero-laterale, impronte delle arcate dentarie. Le misurazioni sulle TLL sono state effettuate sulla base dell'analisi MBT; i valori palatali provengono dai modelli di studio dell’arcata superiore. È stata utilizzato il test t-Student per mettere a confronto il gruppo di studio e il gruppo di controllo riguardo le misure cefalometriche e i valori palatali. Risultati. Nel gruppo di studio sono state rilevate anomalie di numero (un dente deciduo soprannumerario e una agenesia di un dente permanente). Il test t-Student rivela differenze statisticamente significative per 7 variabili cefalometriche su 13 e per 2 variabili palatali. Conclusioni. Basandosi su questo studio è possibile concludere che i pazienti con SN mostrano II classe scheletrica di tipo mandibolare, crescita iperdivergente, tendenza al morso aperto scheletrico, palatoversione degli incisivi superiori, palato stretto. Questi risultati possono fornire informazioni utili sia per la diagnosi di SN sia per la pianificazione del corretto trattamento ortodontico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chromosomal and genetic syndromes are frequently associated with dental and cranio-facial alterations. The aim of our study is to identify and describe the dental and craniofacial alterations typical of six genetic and chromosomal syndromes examined. Materials and Methods- A dental visit was performed to 195 patients referred from Sant’Orsola Hospital of Bologna, University of Bologna, to Service of Special Need Dentistry, Dental Clinic, Department of Biomedical and Neuromotor Science, University of Bologna. The patients recruited were 137 females and 58 males, in an age range of 3-49 years (mean age of 13.8±7.4). The total sample consisted of subjects affected with Down Syndrome (n=133), Familiar Hypophosphatemic Ricket (n=10), Muscular Dystrophies (n=12), Noonan Syndrome (n=13), Turner Syndrome (n=17), Williams Syndrome(n=10). A questionnaire regarding detailed medical and dental history, oral health and dietary habits, was filled by parents/caregivers, or patients themselves when possible. The intra-oral and extra-oral examination valued the presence of facial asymmetries, oral habits, dental and skeletal malocclusions, dental formula, dental anomalies, Plaque Index (Silness&LÖe Index), caries prevalence (dmft/DMFT index), gingivitis and periodontal disease, and mucosal lesions. Radiographic examinations (Intraoral radiographies, Orthopanoramic, Skull teleradiography) were executed according to patient’s age and treatment planning. A review of literature about each syndrome and its dental and cranio-facial characteristics and about caries, hygiene status and malocclusion prevalence on syndromic and non-syndromic population was performed. Results - The data of all the patients were collected in the “Data Collection Tables” created for each syndrome. General anamnesis information, oral hygiene habits and dmft/DMFT, PI, malocclusion prevalence were calculated and compared to syndromic and non-syndromic population results found in literature. Discussions and conclusions - Guidelines of Special Care dentistry were indicated for each syndrome, in relation to each syndrome features and individual patient characteristics.