2 resultados para GLUCOSE-OXIDASE
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Sviluppo di biosensori: modifiche di superfici elettrodiche e sistemi di immobilizzazione enzimatica
Resumo:
An amperometric glucose biosensor was developed using an anionic clay matrix (LDH) as enzyme support. The enzyme glucose oxidase (GOx) was immobilized on a layered double hydroxide Ni/Al-NO3 LDH during the electrosynthesis, which was followed by crosslinking with glutaraldehyde (GA) vapours or with GA and bovine serum albumin (GABSA) to avoid the enzyme release. The electrochemical reaction was carried out potentiostatically, at -0.9V vs. SCE, using a rotating disc Pt electrode to assure homogeneity of the electrodeposition suspension, containing GOx, Ni(NO3)2 and Al(NO3)3 in 0.3 M KNO3. The mechanism responsible of the LDH electrodeposition involves the precipitation of the LDH due to the increase of pH at the surface of the electrode, following the cathodic reduction of nitrates. The Pt surface modified with the Ni/Al-NO3 LDH shows a much reduced noise, giving rise to a better signal to noise ratio for the currents relative to H2O2 oxidation, and a linear range for H2O2 determination wider than the one observed for bare Pt electrodes. We pointed out the performances of the biosensor in terms of sensitivity to glucose, calculated from the slope of the linear part of the calibration curve for enzimatically produced H2O2; the sensitivity was dependent on parameters related to the electrodeposition in addition to working conditions. In order to optimise the glucose biosensor performances, with a reduced number of experimental runs, we applied an experimental design. A first screening was performed considering the following variables: deposition time (30 - 120 s), enzyme concentration (0.5 - 3.0 mg/mL), Ni/Al molar ratio (3:1 or 2:1) of the electrodeposition solution at a total metals concentration of 0.03 M and pH of the working buffer solution (5.5-7.0). On the basis of the results from this screening, a full factorial design was carried out, taking into account only enzyme concentration and Ni/Al molar ratio of the electrosynthesis solution. A full factorial design was performed to study linear interactions between factors and their quadratic effects and the optimal setup was evaluated by the isoresponse curves. The significant factors were: enzyme concentration (linear and quadratic terms) and the interaction between enzyme concentration and Ni/Al molar ratio. Since the major obstacle for application of amperometric glucose biosensors is the interference signal resulting from other electro-oxidizable species present in the real matrices, such as ascorbate (AA), the use of different permselective membranes on Pt-LDHGOx modified electrode was discussed with the aim of improving biosensor selectivity and stability. Conventional membranes obtained using Nafion, glutaraldehyde (GA) vapours, GA-BSA were tested together with more innovative materials like palladium hexacyanoferrate (PdHCF) and titania hydrogels. Particular attention has been devoted to hydrogels, because they possess some attractive features, which are generally considered to favour biosensor materials biocompatibility and, consequently, the functional enzyme stability. The Pt-LDH-GOx-PdHCF hydrogel biosensor presented an anti-interferant ability so that to be applied for an accurate glucose analysis in blood. To further improve the biosensor selectivity, protective membranes containing horseradish peroxidase (HRP) were also investigated with the aim of oxidising the interferants before they reach the electrode surface. In such a case glucose determination was also accomplished in real matrices with high AA content. Furthermore, the application of a LDH containing nickel in the oxidised state was performed not only as a support for the enzyme, but also as anti-interferant sistem. The result is very promising and it could be the starting point for further applications in the field of amperometric biosensors; the study could be extended to other oxidase enzymes.
Resumo:
At the intersection of biology, chemistry, and engineering, biosensors are a multidisciplinary innovation that provide a cost-effective alternative to traditional laboratory techniques. Due to their advantages, biosensors are used in medical diagnostics, environmental monitoring, food safety and many other fields. The first part of the thesis is concerned with learning the state of the art of paper-based immunosensors with bioluminescent (BL) and chemiluminescent (CL) detection. The use of biospecific assays combined with CL detection and paper-based technology offers an optimal approach to creating analytical tools for on-site applications and we have focused on the specific areas that need to be considered more in order to ensure a future practical implementation of these methods in routine analyses. The subsequent part of the thesis addresses the development of an autonomous lab-on-chip platform for performing chemiluminescent-based bioassays in space environment, exploiting a CubeSat platform for astrobiological investigations. An origami-inspired microfluidic paper-based analytical device has been developed with the purpose of assesses its performance in space and to evaluate its functionality and the resilience of the (bio)molecules when exposed to a radiation-rich environment. Subsequently, we designed a paper-based assay to detect traces of ovalbumin in food samples, creating a user-friendly immunosensing platform. To this purpose, we developed an origami device that exploits a competitive immunoassay coupled with chemiluminescence detection and magnetic microbeads used to immobilize ovalbumin on paper. Finally, with the aim of exploring the use of biomimetic materials, an hydrogel-based chemiluminescence biosensor for the detection of H2O2 and glucose was developed. A guanosine hydrogel was prepared and loaded with luminol and hemin, miming a DNAzyme activity. Subsequently, the hydrogel was modified by incorporating glucose oxidase enzyme to enable glucose biosensing. The emitted photons were detected using a portable device equipped with a smartphone's CMOS (complementary metal oxide semiconductor) camera for CL emission detection.