3 resultados para Flexible bronchoscopy

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Lower pole kidney stones represent at time a challenge for the urologist. The gold standard treatment for intrarenal stones <2 cm is Extracorporeal Shock Wave Lithotripsy (ESWL) while for those >2 cm is Percutaneous Nephrolithotomy (PCNL). The success rate of ESWL, however, decreases when it is employed for lower pole stones, and this is particularly true in the presence of narrow calices or acute infundibular angles. Studies have proved that ureteroscopy (URS) is an efficacious alternative to ESWL for lower pole stones <2 cm, but this is not reflected by either the European or the American guidelines. The aim of this study is to present the results of a large series of flexible ureteroscopies and PCNLs for lower pole kidney stones from high-volume centers, in order to provide more evidences on the potential indications of the flexible ureteroscopy for the treatment of kidney stones. Materials and Methods A database was created and the participating centres retrospectively entered their data relating to the percutaneous and flexible ureteroscopic management of lower pole kidney stones. Patients included were treated between January 2005 and January 2010. Variables analyzed included case load number, preoperative and postoperative imaging, stone burden, anaesthesia (general vs. spinal), type of lithotripter, access location and size, access dilation type, ureteral access sheath use, visual clarity, operative time, stone-free rate, complication rate, hospital stay, analgesic requirement and follow-up time. Stone-free rate was defined as absence of residual fragments or presence of a single fragment <2 mm in size at follow-up imaging. Primary end-point was to test the efficacy and safety of flexible URS for the treatment of lower pole stones; the same descriptive analysis was conducted for the PCNL approach, as considered the gold standard for the treatment of lower pole kidney stones. In this setting, no statistical analysis was conducted owing to the different selection criteria of the patients. Secondary end-point consisted in matching the results of stone-free rates, operative time and complications rate of flexible URS and PCNL in the subgroup of patients harbouring lower pole kidney stones between 1 and 2 cm in the higher diameter. Results A total 246 patients met the criteria for inclusion. There were 117 PCNLs (group 1) and 129 flexible URS (group 2). Ninety-six percent of cases were diagnosed by CT KUB scan. Mean stone burden was 175±160 and 50±62 mm2 for groups 1 and 2, respectively. General anaesthesia was induced in 100 % and 80% of groups 1 and 2, respectively. Pneumo-ultrasonic energy was used in 84% of cases in the PCNL group, and holmium laser in 95% of the cases in the flexible URS group. The mean operative time was 76.9±44 and 63±37 minutes for groups 1 and 2 respectively. There were 12 major complications (11%) in group 1 (mainly Grade II complications according to Clavidien classification) and no major complications in group 2. Mean hospital stay was 5.7 and 2.6 days for groups 1 and 2, respectively. Ninety-five percent of group 1 and 52% of group 2 required analgesia for a period longer than 24 hours. Intraoperative stone-free rate after a single treatment was 88.9% for group 1 and 79.1% for group 2. Overall, 6% of group 1 and 14.7% of group 2 required a second look procedure. At 3 months, stone-free rates were 90.6% and 92.2% for groups 1 and 2, respectively, as documented by follow-up CT KUB (22%) or combination of intra-venous pyelogram, regular KUB and/or kidney ultrasound (78%). In the subanalysis conducted comparing 82 vs 65 patients who underwent PCNL and flexible URS for lower pole stones between 1 and 2 cm, intreoperative stone-free rates were 88% vs 68% (p= 0.03), respectively; anyway, after an auxiliary procedure which was necessary in 6% of the cases in group 1 and 23% in group 2 (p=0.03), stone-free rates at 3 months were not statistically significant (91.5% vs 89.2%; p=0.6). Conversely, the patients undergoing PCNL maintained a higher risk of complications during the procedure, with 9 cases observed in this group versus 0 in the group of patients treated with URS (p=0.01) Conclusions These data highlight the value of flexible URS as a very effective and safe option for the treatment of kidney stones; thanks to the latest generation of flexible devices, this new technical approach seems to be a valid alternative in particular for the treatment of lower pole kidney stones less than 2 cm. In high-volume centres and in the hands of skilled surgeons, this technique can approach the stone-free rates achievable through PCNL in lower pole stones between 1 and 2 cm, with a very low risk of complications. Furthermore, the results confirm the high success rate and relatively low morbidity of modern PCNL for lower pole stones, with no difference detectable between the prone and supine position.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a multibody model of a motorbike engine cranktrain is presented in this work, with an emphasis on flexible component model reduction. A modelling methodology based upon the adoption of non-ideal joints at interface locations, and the inclusion of component flexibility, is developed: both are necessary tasks if one wants to capture dynamic effects which arise in lightweight, high-speed applications. With regard to the first topic, both a ball bearing model and a journal bearing model are implemented, in order to properly capture the dynamic effects of the main connections in the system: angular contact ball bearings are modelled according to a five-DOF nonlinear scheme in order to grasp the crankshaft main bearings behaviour, while an impedance-based hydrodynamic bearing model is implemented providing an enhanced operation prediction at the conrod big end locations. Concerning the second matter, flexible models of the crankshaft and the connecting rod are produced. The well-established Craig-Bampton reduction technique is adopted as a general framework to obtain reduced model representations which are suitable for the subsequent multibody analyses. A particular component mode selection procedure is implemented, based on the concept of Effective Interface Mass, allowing an assessment of the accuracy of the reduced models prior to the nonlinear simulation phase. In addition, a procedure to alleviate the effects of modal truncation, based on the Modal Truncation Augmentation approach, is developed. In order to assess the performances of the proposed modal reduction schemes, numerical tests are performed onto the crankshaft and the conrod models in both frequency and modal domains. A multibody model of the cranktrain is eventually assembled and simulated using a commercial software. Numerical results are presented, demonstrating the effectiveness of the implemented flexible model reduction techniques. The advantages over the conventional frequency-based truncation approach are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation deals with the design and the characterization of novel reconfigurable silicon-on-insulator (SOI) devices to filter and route optical signals on-chip. Design is carried out through circuit simulations based on basic circuit elements (Building Blocks, BBs) in order to prove the feasibility of an approach allowing to move the design of Photonic Integrated Circuits (PICs) toward the system level. CMOS compatibility and large integration scale make SOI one of the most promising material to realize PICs. The concepts of generic foundry and BB based circuit simulations for the design are emerging as a solution to reduce the costs and increase the circuit complexity. To validate the BB based approach, the development of some of the most important BBs is performed first. A novel tunable coupler is also presented and it is demonstrated to be a valuable alternative to the known solutions. Two novel multi-element PICs are then analysed: a narrow linewidth single mode resonator and a passband filter with widely tunable bandwidth. Extensive circuit simulations are carried out to determine their performance, taking into account fabrication tolerances. The first PIC is based on two Grating Assisted Couplers in a ring resonator (RR) configuration. It is shown that a trade-off between performance, resonance bandwidth and device footprint has to be performed. The device could be employed to realize reconfigurable add-drop de/multiplexers. Sensitivity with respect to fabrication tolerances and spurious effects is however observed. The second PIC is based on an unbalanced Mach-Zehnder interferometer loaded with two RRs. Overall good performance and robustness to fabrication tolerances and nonlinear effects have confirmed its applicability for the realization of flexible optical systems. Simulated and measured devices behaviour is shown to be in agreement thus demonstrating the viability of a BB based approach to the design of complex PICs.