7 resultados para Exponential power distribution

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Investigation on impulsive signals, originated from Partial Discharge (PD) phenomena, represents an effective tool for preventing electric failures in High Voltage (HV) and Medium Voltage (MV) systems. The determination of both sensors and instruments bandwidths is the key to achieve meaningful measurements, that is to say, obtaining the maximum Signal-To-Noise Ratio (SNR). The optimum bandwidth depends on the characteristics of the system under test, which can be often represented as a transmission line characterized by signal attenuation and dispersion phenomena. It is therefore necessary to develop both models and techniques which can characterize accurately the PD propagation mechanisms in each system and work out the frequency characteristics of the PD pulses at detection point, in order to design proper sensors able to carry out PD measurement on-line with maximum SNR. Analytical models will be devised in order to predict PD propagation in MV apparatuses. Furthermore, simulation tools will be used where complex geometries make analytical models to be unfeasible. In particular, PD propagation in MV cables, transformers and switchgears will be investigated, taking into account both irradiated and conducted signals associated to PD events, in order to design proper sensors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis is focused on Smart Grid applications in medium voltage distribution networks. For the development of new applications it appears useful the availability of simulation tools able to model dynamic behavior of both the power system and the communication network. Such a co-simulation environment would allow the assessment of the feasibility of using a given network technology to support communication-based Smart Grid control schemes on an existing segment of the electrical grid and to determine the range of control schemes that different communications technologies can support. For this reason, is presented a co-simulation platform that has been built by linking the Electromagnetic Transients Program Simulator (EMTP v3.0) with a Telecommunication Network Simulator (OPNET-Riverbed v18.0). The simulator is used to design and analyze a coordinate use of Distributed Energy Resources (DERs) for the voltage/var control (VVC) in distribution network. This thesis is focused control structure based on the use of phase measurement units (PMUs). In order to limit the required reinforcements of the communication infrastructures currently adopted by Distribution Network Operators (DNOs), the study is focused on leader-less MAS schemes that do not assign special coordinating rules to specific agents. Leader-less MAS are expected to produce more uniform communication traffic than centralized approaches that include a moderator agent. Moreover, leader-less MAS are expected to be less affected by limitations and constraint of some communication links. The developed co-simulator has allowed the definition of specific countermeasures against the limitations of the communication network, with particular reference to the latency and loss and information, for both the case of wired and wireless communication networks. Moreover, the co-simulation platform has bee also coupled with a mobility simulator in order to study specific countermeasures against the negative effects on the medium voltage/current distribution network caused by the concurrent connection of electric vehicles.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La corretta modellizzazione della zona del riflettore dei sistemi GEN III+ è un passaggio fondamentale per un’accurata predizione dei parametri di cella il cui valore influenza direttamente la distribuzione di potenza su tutto il nocciolo. Tale esigenza si è resa ancora più stringente dopo la constatazione che il fenomeno del “tilt power” risulta essere più amplificato nei noccioli nucleari equipaggiati con un riflettore pesante. Per tali ragioni, nel presente lavoro di tesi si è dedicata particolare attenzione alle metodiche di modellizzazione ed alla generazione delle sezioni d’urto efficaci omogenee ed agli assembly discontinuity factors (ADF) nella zona di riflessione. Il codice deterministico utilizzato per il calcolo è SCALE 6.1.3. La notevole differenza nelle proprietà neutroniche associata ad un’elevata eterogeneità geometrica tra un nocciolo ed un riflettore hanno suggerito di effettuare un’analisi preliminare sul sistema riflettente GEN II proposto nel benchmark NEA-NSC-DOC (2013) per testare la capacità di SCALE 6.1.3 di effettuare un corretto calcolo di cella adottando una modellizzazione monodimensionale assembly/riflettore. I risultati ottenuti sono confrontati con quelli presentati nel benchmark e e con quelli valutati attraverso il codice Monte Carlo SERPENT 2.0 confermando la capacità di calcolo di SCALE 6.1.3. L’analisi sulla modellizzazione dei sistemi riflettenti GEN III+ è stata effettuata ricavando il valore dei parametri di cella per configurazioni omogenee ed una serie di configurazioni geometriche esatte che comprendono tutte le modellizzazioni del sistema riflettente lungo la direzione angolare del riflettore. Si è inoltre effettuata un’analisi di sensitività su parametri operativi e sui parametri di codice. Si è infine effettuato un calcolo in color-set per indagare l’influenza degli effetti 2-D sui parametri di cella. I risultati prodotti rappresentano un contributo migliorativo nella conoscenza dei parametri di cella di riflettore e potranno essere utilizzati per una più precisa valutazione del fenomeno del tilt nei sistemi GEN III+.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The research activity carried out during the PhD course in Electrical Engineering belongs to the branch of electric and electronic measurements. The main subject of the present thesis is a distributed measurement system to be installed in Medium Voltage power networks, as well as the method developed to analyze data acquired by the measurement system itself and to monitor power quality. In chapter 2 the increasing interest towards power quality in electrical systems is illustrated, by reporting the international research activity inherent to the problem and the relevant standards and guidelines emitted. The aspect of the quality of voltage provided by utilities and influenced by customers in the various points of a network came out only in recent years, in particular as a consequence of the energy market liberalization. Usually, the concept of quality of the delivered energy has been associated mostly to its continuity. Hence the reliability was the main characteristic to be ensured for power systems. Nowadays, the number and duration of interruptions are the “quality indicators” commonly perceived by most customers; for this reason, a short section is dedicated also to network reliability and its regulation. In this contest it should be noted that although the measurement system developed during the research activity belongs to the field of power quality evaluation systems, the information registered in real time by its remote stations can be used to improve the system reliability too. Given the vast scenario of power quality degrading phenomena that usually can occur in distribution networks, the study has been focused on electromagnetic transients affecting line voltages. The outcome of such a study has been the design and realization of a distributed measurement system which continuously monitor the phase signals in different points of a network, detect the occurrence of transients superposed to the fundamental steady state component and register the time of occurrence of such events. The data set is finally used to locate the source of the transient disturbance propagating along the network lines. Most of the oscillatory transients affecting line voltages are due to faults occurring in any point of the distribution system and have to be seen before protection equipment intervention. An important conclusion is that the method can improve the monitored network reliability, since the knowledge of the location of a fault allows the energy manager to reduce as much as possible both the area of the network to be disconnected for protection purposes and the time spent by technical staff to recover the abnormal condition and/or the damage. The part of the thesis presenting the results of such a study and activity is structured as follows: chapter 3 deals with the propagation of electromagnetic transients in power systems by defining characteristics and causes of the phenomena and briefly reporting the theory and approaches used to study transients propagation. Then the state of the art concerning methods to detect and locate faults in distribution networks is presented. Finally the attention is paid on the particular technique adopted for the same purpose during the thesis, and the methods developed on the basis of such approach. Chapter 4 reports the configuration of the distribution networks on which the fault location method has been applied by means of simulations as well as the results obtained case by case. In this way the performance featured by the location procedure firstly in ideal then in realistic operating conditions are tested. In chapter 5 the measurement system designed to implement the transients detection and fault location method is presented. The hardware belonging to the measurement chain of every acquisition channel in remote stations is described. Then, the global measurement system is characterized by considering the non ideal aspects of each device that can concur to the final combined uncertainty on the estimated position of the fault in the network under test. Finally, such parameter is computed according to the Guide to the Expression of Uncertainty in Measurements, by means of a numeric procedure. In the last chapter a device is described that has been designed and realized during the PhD activity aiming at substituting the commercial capacitive voltage divider belonging to the conditioning block of the measurement chain. Such a study has been carried out aiming at providing an alternative to the used transducer that could feature equivalent performance and lower cost. In this way, the economical impact of the investment associated to the whole measurement system would be significantly reduced, making the method application much more feasible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The digital electronic market development is founded on the continuous reduction of the transistors size, to reduce area, power, cost and increase the computational performance of integrated circuits. This trend, known as technology scaling, is approaching the nanometer size. The lithographic process in the manufacturing stage is increasing its uncertainty with the scaling down of the transistors size, resulting in a larger parameter variation in future technology generations. Furthermore, the exponential relationship between the leakage current and the threshold voltage, is limiting the threshold and supply voltages scaling, increasing the power density and creating local thermal issues, such as hot spots, thermal runaway and thermal cycles. In addiction, the introduction of new materials and the smaller devices dimension are reducing transistors robustness, that combined with high temperature and frequently thermal cycles, are speeding up wear out processes. Those effects are no longer addressable only at the process level. Consequently the deep sub-micron devices will require solutions which will imply several design levels, as system and logic, and new approaches called Design For Manufacturability (DFM) and Design For Reliability. The purpose of the above approaches is to bring in the early design stages the awareness of the device reliability and manufacturability, in order to introduce logic and system able to cope with the yield and reliability loss. The ITRS roadmap suggests the following research steps to integrate the design for manufacturability and reliability in the standard CAD automated design flow: i) The implementation of new analysis algorithms able to predict the system thermal behavior with the impact to the power and speed performances. ii) High level wear out models able to predict the mean time to failure of the system (MTTF). iii) Statistical performance analysis able to predict the impact of the process variation, both random and systematic. The new analysis tools have to be developed beside new logic and system strategies to cope with the future challenges, as for instance: i) Thermal management strategy that increase the reliability and life time of the devices acting to some tunable parameter,such as supply voltage or body bias. ii) Error detection logic able to interact with compensation techniques as Adaptive Supply Voltage ASV, Adaptive Body Bias ABB and error recovering, in order to increase yield and reliability. iii) architectures that are fundamentally resistant to variability, including locally asynchronous designs, redundancy, and error correcting signal encodings (ECC). The literature already features works addressing the prediction of the MTTF, papers focusing on thermal management in the general purpose chip, and publications on statistical performance analysis. In my Phd research activity, I investigated the need for thermal management in future embedded low-power Network On Chip (NoC) devices.I developed a thermal analysis library, that has been integrated in a NoC cycle accurate simulator and in a FPGA based NoC simulator. The results have shown that an accurate layout distribution can avoid the onset of hot-spot in a NoC chip. Furthermore the application of thermal management can reduce temperature and number of thermal cycles, increasing the systemreliability. Therefore the thesis advocates the need to integrate a thermal analysis in the first design stages for embedded NoC design. Later on, I focused my research in the development of statistical process variation analysis tool that is able to address both random and systematic variations. The tool was used to analyze the impact of self-timed asynchronous logic stages in an embedded microprocessor. As results we confirmed the capability of self-timed logic to increase the manufacturability and reliability. Furthermore we used the tool to investigate the suitability of low-swing techniques in the NoC system communication under process variations. In this case We discovered the superior robustness to systematic process variation of low-swing links, which shows a good response to compensation technique as ASV and ABB. Hence low-swing is a good alternative to the standard CMOS communication for power, speed, reliability and manufacturability. In summary my work proves the advantage of integrating a statistical process variation analysis tool in the first stages of the design flow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The safety systems of nuclear power plants rely on low-voltage power, instrumentation and control cables. Inside the containment area, cables operate in harsh environments, characterized by relatively high temperature and gamma-irradiation. As these cables are related to fundamental safety systems, they must be able to withstand unexpected accident conditions and, therefore, their condition assessment is of utmost importance as plants age and lifetime extensions are required. Nowadays, the integrity and functionality of these cables are monitored mainly through destructive test which requires specific laboratory. The investigation of electrical aging markers which can provide information about the state of the cable by non-destructive testing methods would improve significantly the present diagnostic techniques. This work has been made within the framework of the ADVANCE (Aging Diagnostic and Prognostics of Low-Voltage I\&C Cables) project, a FP7 European program. This Ph.D. thesis aims at studying the impact of aging on cable electrical parameters, in order to understand the evolution of the electrical properties associated with cable degradation. The identification of suitable aging markers requires the comparison of the electrical property variation with the physical/chemical degradation mechanisms of polymers for different insulating materials and compositions. The feasibility of non-destructive electrical condition monitoring techniques as potential substitutes for destructive methods will be finally discussed studying the correlation between electrical and mechanical properties. In this work, the electrical properties of cable insulators are monitored and characterized mainly by dielectric spectroscopy, polarization/depolarization current analysis and space charge distribution. Among these techniques, dielectric spectroscopy showed the most promising results; by means of dielectric spectroscopy it is possible to identify the frequency range where the properties are more sensitive to aging. In particular, the imaginary part of permittivity at high frequency, which is related to oxidation, has been identified as the most suitable aging marker based on electrical quantities.