4 resultados para Decade of the sixties

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this proposal is to explain the paradigm of the American foreign policy during the Johnson Administration, especially toward Europe, within the NATO framework, and toward URSS, in the context of the détente, just emerged during the decade of the sixties. During that period, after the passing of the J. F. Kennedy, President L. B. Johnson inherited a complex and very high-powered world politics, which wanted to get a new phase off the ground in the transatlantic relations and share the burden of the Cold war with a refractory Europe. Known as the grand design, it was a policy that needed the support of the allies and a clear purpose which appealed to the Europeans. At first, President Johnson detected in the problem of the nuclear sharing the good deal to make with the NATO allies. At the same time, he understood that the United States needed to reassert their leadeship within the new stage of relations with the Soviet Union. Soon, the “transatlantic bargain” became something not so easy to dealt with. The Federal Germany wanted to say a word in the nuclear affairs and, why not, put the finger on the trigger of the atlantic nuclear weapons. URSS, on the other hand, wanted to keep Germany down. The other allies did not want to share the onus of the defense of Europe, at most the responsability for the use of the weapons and, at least, to participate in the decision-making process. France, which wanted to detach herself from the policy of the United States and regained a world role, added difficulties to the manage of this course of action. Through the years of the Johnson’s office, the divergences of the policies placed by his advisers to gain the goal put the American foreign policy in deep water. The withdrawal of France from the organization but not from the Alliance, give Washington a chance to carry out his goal. The development of a clear-cut disarm policy leaded the Johnson’s administration to the core of the matter. The Non-proliferation Treaty signed in 1968, solved in a business-like fashion the problem with the allies. The question of nuclear sharing faded away with the acceptance of more deep consultative role in the nuclear affairs by the allies, the burden for the defense of Europe became more bearable through the offset agreement with the FRG and a new doctrine, the flexible response, put an end, at least formally, to the taboo of the nuclear age. The Johnson’s grand design proved to be different from the Kennedy’s one, but all things considered, it was more workable. The unpredictable result was a real détente with the Soviet Union, which, we can say, was a merit of President Johnson.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the last decade advances in the field of sensor design and improved base materials have pushed the radiation hardness of the current silicon detector technology to impressive performance. It should allow operation of the tracking systems of the Large Hadron Collider (LHC) experiments at nominal luminosity (1034 cm-2s-1) for about 10 years. The current silicon detectors are unable to cope with such an environment. Silicon carbide (SiC), which has recently been recognized as potentially radiation hard, is now studied. In this work it was analyzed the effect of high energy neutron irradiation on 4H-SiC particle detectors. Schottky and junction particle detectors were irradiated with 1 MeV neutrons up to fluence of 1016 cm-2. It is well known that the degradation of the detectors with irradiation, independently of the structure used for their realization, is caused by lattice defects, like creation of point-like defect, dopant deactivation and dead layer formation and that a crucial aspect for the understanding of the defect kinetics at a microscopic level is the correct identification of the crystal defects in terms of their electrical activity. In order to clarify the defect kinetic it were carried out a thermal transient spectroscopy (DLTS and PICTS) analysis of different samples irradiated at increasing fluences. The defect evolution was correlated with the transport properties of the irradiated detector, always comparing with the un-irradiated one. The charge collection efficiency degradation of Schottky detectors induced by neutron irradiation was related to the increasing concentration of defects as function of the neutron fluence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last decade, sensitive observations have revealed that disc galaxies are surrounded by multiphase gaseous halos produced by the circulation of gas from the discs to the environment and vice-versa. This Thesis is a study of the gaseous halo of the Milky Way carried out via the modelling of the HI emission and the available absorption-line data. We fitted simple kinematical models to the HI LAB Survey and found that the Galaxy has a massive (~3x10^8 Mo) HI halo extending a few kiloparsecs above the plane. This layer rotates more slowly than the disc and shows a global inflow motion, a kinematics similar to that observed in the HI halos of nearby galaxies. We built a dynamical model of the galactic fountain to reproduce the properties of this layer. In this model, fountain clouds are ejected from the disc by SN feedback and - as suggested by hydrodynamical simulations - triggers the cooling of coronal gas, which is entrained by the cloud wakes and accretes onto the disc when the clouds fall back. For a proper choice of the parameters, the model reproduces well the HI data and predicts an accretion of coronal gas onto the disc at a rate of 2 Mo/yr. We extended this model to the warm-hot component of the halo, showing that most of the ion absorption features observed towards background sources are consistent with being produced in the turbulent wakes that lag behind the fountain clouds. Specifically, the column densities, positions, and velocities of the absorbers are well reproduced by our model. Finally, we studied the gas content of galaxies extracted from a cosmological N-body+SPH simulation, and found that an HI halo with the forementioned properties is not observed, probably due ti the relatively low resolution of the simulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multidetector row computed tomography over the last decade is commonly used in veterinary medicine. This new technology has an increased spatial and temporal resolution, could evaluate wider scanning range in shorter scanning time, providing an advanced imaging modality. Computed tomography angiographic studies are commonly used in veterinary medicine in order to evaluate vascular structures of the abdomen and the thorax. Pulmonary pathology in feline patients is a very common condition and usually is further evaluating with computed tomography. Up to date few references of the normal computed tomographic aspects of the feline thorax are reported. In this study a computed tomographic pulmonary angiography (CTPA) protocol is reported in normal cats and is compared with the up to date anatomical references. A CTPA protocol using a 64 MDCT in our study achieved high resolution images of the pulmonary arteries, pulmonary veins and bronchial lumen till the level of minor segmental branches. Feline pulmonary bronchial parenchyma demonstrates an architecture of mixed type with a monopedial model observed in the most anatomical parts and the dichotomic aspect is seen at the accessory lobe. The arterial and venous architecture is similar to the bronchial. Statistical analysis demonstrates the linear correlation of tracheal diameter to the felines weight. Vascular variations were noticed. The pulmonary venous system enters into the left atrium through three ostia (left cranial ostia: consisted of the anastomosis of the cranial and caudal portion of the left cranial pulmonary vein; right ostia: consisted of the anastomosis of the right cranial and middle pulmonary vein; and the caudal ostia: consisted of the anastomosis of the right and left caudal pulmonary vein). In conclusion CTPA is applicable in feline patients and provides an excellent imaging of the pulmonary arterial, venous and bronchial system till the level of minor segmental branches.