5 resultados para DIAPHRAGM MAGNETOMETER

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This artwork reports on two different projects that were carried out during the three years of Doctor of the Philosophy course. In the first years a project regarding Capacitive Pressure Sensors Array for Aerodynamic Applications was developed in the Applied Aerodynamic research team of the Second Faculty of Engineering, University of Bologna, Forlì, Italy, and in collaboration with the ARCES laboratories of the same university. Capacitive pressure sensors were designed and fabricated, investigating theoretically and experimentally the sensor’s mechanical and electrical behaviours by means of finite elements method simulations and by means of wind tunnel tests. During the design phase, the sensor figures of merit are considered and evaluated for specific aerodynamic applications. The aim of this work is the production of low cost MEMS-alternative devices suitable for a sensor network to be implemented in air data system. The last two year was dedicated to a project regarding Wireless Pressure Sensor Network for Nautical Applications. Aim of the developed sensor network is to sense the weak pressure field acting on the sail plan of a full batten sail by means of instrumented battens, providing a real time differential pressure map over the entire sail surface. The wireless sensor network and the sensing unit were designed, fabricated and tested in the faculty laboratories. A static non-linear coupled mechanical-electrostatic simulation, has been developed to predict the pressure versus capacitance static characteristic suitable for the transduction process and to tune the geometry of the transducer to reach the required resolution, sensitivity and time response in the appropriate full scale pressure input A time dependent viscoelastic error model has been inferred and developed by means of experimental data in order to model, predict and reduce the inaccuracy bound due to the viscolelastic phenomena affecting the Mylar® polyester film used for the sensor diaphragm. The development of the two above mentioned subjects are strictly related but presently separately in this artwork.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this thesis was to describe the development of motion analysis protocols for applications on upper and lower limb extremities, by using inertial sensors-based systems. Inertial sensors-based systems are relatively recent. Knowledge and development of methods and algorithms for the use of such systems for clinical purposes is therefore limited if compared with stereophotogrammetry. However, their advantages in terms of low cost, portability, small size, are a valid reason to follow this direction. When developing motion analysis protocols based on inertial sensors, attention must be given to several aspects, like the accuracy of inertial sensors-based systems and their reliability. The need to develop specific algorithms/methods and software for using these systems for specific applications, is as much important as the development of motion analysis protocols based on them. For this reason, the goal of the 3-years research project described in this thesis was achieved first of all trying to correctly design the protocols based on inertial sensors, in terms of exploring and developing which features were suitable for the specific application of the protocols. The use of optoelectronic systems was necessary because they provided a gold standard and accurate measurement, which was used as a reference for the validation of the protocols based on inertial sensors. The protocols described in this thesis can be particularly helpful for rehabilitation centers in which the high cost of instrumentation or the limited working areas do not allow the use of stereophotogrammetry. Moreover, many applications requiring upper and lower limb motion analysis to be performed outside the laboratories will benefit from these protocols, for example performing gait analysis along the corridors. Out of the buildings, the condition of steady-state walking or the behavior of the prosthetic devices when encountering slopes or obstacles during walking can also be assessed. The application of inertial sensors on lower limb amputees presents conditions which are challenging for magnetometer-based systems, due to ferromagnetic material commonly adopted for the construction of idraulic components or motors. INAIL Prostheses Centre stimulated and, together with Xsens Technologies B.V. supported the development of additional methods for improving the accuracy of MTx in measuring the 3D kinematics for lower limb prostheses, with the results provided in this thesis. In the author’s opinion, this thesis and the motion analysis protocols based on inertial sensors here described, are a demonstration of how a strict collaboration between the industry, the clinical centers, the research laboratories, can improve the knowledge, exchange know-how, with the common goal to develop new application-oriented systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lung ultrasound use is increasing in respiratory medicine thanks to its development in the latest years. Actually it allows to study diseases of the chest wall (traumas, infections, neoplasms), diaphragm (paralysis, ipokinesis), pleura (effusions, pneumothorax, thickenings, neoplasms) and lung parenchyma (consolidations, interstitial syndromes, peripheral lesions). One of the most useful application of chest ultrasound is the evaluation of effusions. However, no standardized approach for ultrasound-guided thoracenthesis is available. Our study showed that our usual ultrasonographic landmark (“V-point”) could be a standard site to perform thoracenthesis: in 45 thoracenthesis no pneumothorax occurred, drainage was always successful at first attempt. Values of maximum thickness at V-point and drained fluid volume showed a significative correlation. Proteins concentration of ultrasound patterns of effusions (anechoic, ipoechoic, moving echoic spots, dense moving spots, hyperechoic) were compared to those of the macroscopic features of fluids showing connection between light-yellow fluid and echoic moving spots pattern and between ipoechoic/dense moving spots and cloudy-yellow/serum-haematic fluids. These observations suggest that ultrasound could predict chemical-physical features of effusions. Lung ultrasound provides useful information about many disease of the lung, but actually there is not useful in obstructive bronchial diseases. Analysing diaphragmatic kinetics using M-mode through transhepatic scan we described a similarity between diaphragm excursion during an expiratory forced maneuver and the volume/time curve of spirometry. This allowed us to identify the M-mode Index of Obstruction (MIO), an ultrasound-analogue of FEV1/VC. We observed MIO values of normal subjects (9) and obstructed patients (9) comparing the two groups. FEV1/VC and MIO showed a significant correlation suggesting that MIO may be affected by airways obstruction; MIO values were significatively different between normal and obstructed so that it could identify an obstructive syndrome. The data show that it is possible to suspect the presence of obstructive syndrome of the airways using ultrasonography of the diaphragm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the influence of the diaphragm flexibility on the behavior of out-of-plane walls in masonry buildings. Simplified models have been developed to perform kinematic and dynamic analyses in order to compare the response of walls with different restraint conditions. Kinematic non linear analyses of assemblages of rigid blocks have been performed to obtain the acceleration-displacement curves for walls with different restraint conditions at the top. A simplified 2DOF model has been developed to analyse the dynamic response of the wall with an elastic spring at the top, following the Housner rigid behaviour hypothesis. The dissipation of energy is concentrated at every impact at the base of the wall and is modelled through the introduction of the coefficient of restitution. The sets of equations of the possible configurations of the wall, depending on the different positions of the centre of rotation at the base and at the intermediate hinge have been obtained. An algorithm for the numerical integration of the sets of the equations of motion in the time domain has been developed. Dynamic analyses of a set of walls with Gaussian impulses and recorded accelerograms inputs have been performed in order to compare the response of the simply supported wall with the one of the wall with elastic spring at the top. The influence of diaphragm stiffness Kd has been investigated determining the variation of maximum displacement demand with the value of Kd. A more regular trend has been obtained for the Gaussian input than for the recorded accelerograms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Obbiettivo. Analizzare la funzionalità polmonare e diaframmatica dopo interventi di plicatura del diaframma con rete di rinforzo peri-costale eseguiti per relaxatio e riparazione di ernia transdiaframmatica cronica mediante riduzione e sutura diretta. Metodi. Dal 1996 al 2010, 10 pazienti con relaxatio unilaterale del diaframma e 6 pazienti con ernia transdiaframmatica cronica misconosciuta sono stati sottoposti a chirurgia elettiva. Gli accertamenti preoperatori e al follow-up di 12 mesi includevano prove di funzionalità respiratoria, misura della pressione massimale inspiratoria alla bocca in clino e ortostatismo, emogasanlisi, TC del torace e dispnea score. Risultati. I pazienti dei due gruppi non differivano in termini di funzionalità respiratoria preoperatoria nè di complicanze postoperatorie; al follow-up a 12 mesi il gruppo Eventrazione mostrava un significativo aumento del FEV1% (+18,2 – p<0.001), FVC% (+12,8 – p<0.001), DLCO% (+6,84 – p=0,04) e pO2 (+9,8 mmHg – p<0.001). Al contrario nrl gruppo Ernia solo il miglioramento della pO2 era significativo (+8.3 – p=0.04). Sebbene la massima pressione inspiratoria (PImax) fosse aumentata in entrambi i gruppi al follow-up, i pazienti operati per ernia mostravano un miglioramento limitato con persistente caduta significativa della PImax dall’ortostatismo al clinostatismo (p<0.001). Il Transitional dyspnoea score è stato concordante con tali miglioramenti pur senza differenze significative tra i due gruppi. La TC del torace ha evidenziato una sopraelevazione dell’emidiaframma suturato, senza recidiva di ernia, mentre i pazienti sottoposti a plicatura hanno mantenuto l’ipercorrezione. Conclusioni. L’utilizzo di un rinforzo protesico è sicuro e sembra assicurare risultati funzionali migliori a distanza in termini di flussi respiratori e di movimento paradosso del diaframma (valutato mediante PImax). Lacerazioni estese del diaframma coinvolgenti le branche principali di suddivisione del nervo frenico si associano verosimilmente a una relaxatio che può quindi ridurre il guadagno funzionale a lungo termine se non adeguatamente trattata mediante l’utilizzo di un rinforzo protesico.