2 resultados para Cavernous sinus

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction The “eversion” technique for carotid endarterectomy (e-CEA), that involves the transection of the internal carotid artery at the carotid bulb and its eversion over the atherosclerotic plaque, has been associated with an increased risk of postoperative hypertension possibly due to a direct iatrogenic damage to the carotid sinus fibers. The aim of this study is to assess the long-term effect of the e-CEA on arterial baroreflex and peripheral chemoreflex function in humans. Methods A retrospective review was conducted on a prospectively compiled computerized database of 3128 CEAs performed on 2617 patients at our Center between January 2001 and March 2006. During this period, a total of 292 patients who had bilateral carotid stenosis ≥70% at the time of the first admission underwent staged bilateral CEAs. Of these, 93 patients had staged bilateral e-CEAs, 126 staged bilateral s- CEAs and 73 had different procedures on each carotid. CEAs were performed with either the eversion or the standard technique with routine Dacron patching in all cases. The study inclusion criteria were bilateral CEA with the same technique on both sides and an uneventful postoperative course after both procedures. We decided to enroll patients submitted to bilateral e-CEA to eliminate the background noise from contralateral carotid sinus fibers. Exclusion criteria were: age >70 years, diabetes mellitus, chronic pulmonary disease, symptomatic ischemic cardiac disease or medical therapy with b-blockers, cardiac arrhythmia, permanent neurologic deficits or an abnormal preoperative cerebral CT scan, carotid restenosis and previous neck or chest surgery or irradiation. Young and aged-matched healthy subjects were also recruited as controls. Patients were assessed by the 4 standard cardiovascular reflex tests, including Lying-to-standing, Orthostatic hypotension, Deep breathing, and Valsalva Maneuver. Indirect autonomic parameters were assessed with a non-invasive approach based on spectral analysis of EKG RR interval, systolic arterial pressure, and respiration variability, performed with an ad hoc software. From the analysis of these parameters the software provides the estimates of spontaneous baroreflex sensitivity (BRS). The ventilatory response to hypoxia was assessed in patients and controls by means of classic rebreathing tests. Results A total of 29 patients (16 males, age 62.4±8.0 years) were enrolled. Overall, 13 patients had undergone bilateral e-CEA (44.8%) and 16 bilateral s-CEA (55.2%) with a mean interval between the procedures of 62±56 days. No patient showed signs or symptoms of autonomic dysfunction, including labile hypertension, tachycardia, palpitations, headache, inappropriate diaphoresis, pallor or flushing. The results of standard cardiovascular autonomic tests showed no evidence of autonomic dysfunction in any of the enrolled patients. At spectral analysis, a residual baroreflex performance was shown in both patient groups, though reduced, as expected, compared to young controls. Notably, baroreflex function was better maintained in e-CEA, compared to standard CEA. (BRS at rest: young controls 19.93 ± 2.45 msec/mmHg; age-matched controls 7.75 ± 1.24; e-CEA 13.85 ± 5.14; s-CEA 4.93 ± 1.15; ANOVA P=0.001; BRS at stand: young controls 7.83 ± 0.66; age-matched controls 3.71 ± 0.35; e-CEA 7.04 ± 1.99; s-CEA 3.57 ± 1.20; ANOVA P=0.001). In all subjects ventilation (VÝ E) and oximetry data fitted a linear regression model with r values > 0.8. Oneway analysis of variance showed a significantly higher slope both for ΔVE/ΔSaO2 in controls compared with both patient groups which were not different from each other (-1.37 ± 0.33 compared with -0.33±0.08 and -0.29 ±0.13 l/min/%SaO2, p<0.05, Fig.). Similar results were observed for and ΔVE/ΔPetO2 (-0.20 ± 0.1 versus -0.01 ± 0.0 and -0.07 ± 0.02 l/min/mmHg, p<0.05). A regression model using treatment, age, baseline FiCO2 and minimum SaO2 achieved showed only treatment as a significant factor in explaining the variance in minute ventilation (R2= 25%). Conclusions Overall, we demonstrated that bilateral e-CEA does not imply a carotid sinus denervation. As a result of some expected degree of iatrogenic damage, such performance was lower than that of controls. Interestingly though, baroreflex performance appeared better maintained in e-CEA than in s-CEA. This may be related to the changes in the elastic properties of the carotid sinus vascular wall, as the patch is more rigid than the endarterectomized carotid wall that remains in the e-CEA. These data confirmed the safety of CEA irrespective of the surgical technique and have relevant clinical implication in the assessment of the frequent hemodynamic disturbances associated with carotid angioplasty stenting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: sebbene la letteratura recente abbia suggerito che l’utilizzo degli impianti corti possa rappresentare una alternative preferibile alle procedure di rigenerazione ossea nelle aree posteriori atrofiche, perché è un trattamento più semplice e con meno complicazioni, esistono solo pochi studi a medio e lungo termine che abbiano comparato queste tecniche. Scopo: lo scopo di questo studio retrospettivo è quello di valutare se gli impianti corti (6-8 mm) (gruppo impianti corti) possano presentare percentuali di sopravvivenza e valori di riassorbimento osseo marginali simili a impianti di dimensioni standard (≥11 mm) inseriti contemporaneamente ad una grande rialzo di seno mascellare. Materiali e Metodi: in totale, 101 pazienti sono stati inclusi: 48 nel gruppo impianti corti e 53 nel gruppo seno. In ciascun paziente da 1 a 3 impianti sono stati inseriti e tenuti sommersi per 4-6 mesi. I parametri clinici e radiografici valutati sono: i fallimenti implantari, le complicazioni, lo stato dei tessuti molli, e il riassorbimento osseo marginale. Tutti i pazienti sono stati seguiti per almeno 3 anni dal posizionamento implantare. Risultati: il periodo di osservazione medio è stato di 43.47 ± 6.1 mesi per il gruppo impianti corti e 47.03 ± 7.46 mesi per il gruppo seno. Due su 101 impianti corti e 6 su 108 impianti standard sono falliti. Al follow-up finale, si è riscontrato un riassorbimento osseo medio di 0.47 ± 0.48 mm nel gruppo impianti corti versus 0.64 ± 0.58 mm nel gruppo seno. Non sono presenti differenze statisticamente significative fra i gruppi in termini di fallimenti implantari, complicazioni protesiche, tessuti molli, e riassorbimento osseo. Il gruppo seno ha presentato, invece, un maggior numero di complicazioni chirurgiche. Conclusioni: entrambe le tecniche hanno dimostrato un simile tasso di successo clinico e radiografico, ma gli impianti corti hanno ridotto il numero di complicazioni chirurgiche.