12 resultados para CMS detectors
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
During the last decade advances in the field of sensor design and improved base materials have pushed the radiation hardness of the current silicon detector technology to impressive performance. It should allow operation of the tracking systems of the Large Hadron Collider (LHC) experiments at nominal luminosity (1034 cm-2s-1) for about 10 years. The current silicon detectors are unable to cope with such an environment. Silicon carbide (SiC), which has recently been recognized as potentially radiation hard, is now studied. In this work it was analyzed the effect of high energy neutron irradiation on 4H-SiC particle detectors. Schottky and junction particle detectors were irradiated with 1 MeV neutrons up to fluence of 1016 cm-2. It is well known that the degradation of the detectors with irradiation, independently of the structure used for their realization, is caused by lattice defects, like creation of point-like defect, dopant deactivation and dead layer formation and that a crucial aspect for the understanding of the defect kinetics at a microscopic level is the correct identification of the crystal defects in terms of their electrical activity. In order to clarify the defect kinetic it were carried out a thermal transient spectroscopy (DLTS and PICTS) analysis of different samples irradiated at increasing fluences. The defect evolution was correlated with the transport properties of the irradiated detector, always comparing with the un-irradiated one. The charge collection efficiency degradation of Schottky detectors induced by neutron irradiation was related to the increasing concentration of defects as function of the neutron fluence.
Resumo:
This thesis is mainly about the search for exotic heavy particles -Intermediate Mass Magnetic Monopoles, Nuclearites and Q-balls with the SLIM experiment at the Chacaltaya High Altitude Laboratory (5230 m, Bolivia), establishing upper limits (90% CL) in the absence of candidates, which are among the best if not the only one for all three kind of particles. A preliminary study of the background induced by cosmic neutron in CR39 at the SLIM site, using Monte Carlo simulations. The measurement of the elemental abundance of the primary cosmic ray with the CAKE experiment on board of a stratospherical balloon; the charge distribution obtained spans in the range 5≤Z≤31. Both experiments were based on the use of plastic Nuclear Track Detectors, which records the passage of ionizing particles; by using some chemical reagents such passage can be make visible at optical microscopes.
Resumo:
This thesis comes after a strong contribution on the realization of the CMS computing system, which can be seen as a relevant part of the experiment itself. A physics analysis completes the road from Monte Carlo production and analysis tools realization to the final physics study which is the actual goal of the experiment. The topic of physics work of this thesis is the study of tt events fully hadronic decay in the CMS experiment. A multi-jet trigger has been provided to fix a reasonable starting point, reducing the multi-jet sample to the nominal trigger rate. An offline selection has been provided to reduce the S/B ratio. The b-tag is applied to provide a further S/B improvement. The selection is applied to the background sample and to the samples generated at different top quark masses. The top quark mass candidate is reconstructed for all those samples using a kinematic fitter. The resulting distributions are used to build p.d.f.’s, interpolating them with a continuous arbitrary curve. These curves are used to perform the top mass measurement through a likelihood comparison
Resumo:
In the present study we are using multi variate analysis techniques to discriminate signal from background in the fully hadronic decay channel of ttbar events. We give a brief introduction to the role of the Top quark in the standard model and a general description of the CMS Experiment at LHC. We have used the CMS experiment computing and software infrastructure to generate and prepare the data samples used in this analysis. We tested the performance of three different classifiers applied to our data samples and used the selection obtained with the Multi Layer Perceptron classifier to give an estimation of the statistical and systematical uncertainty on the cross section measurement.
Resumo:
Monte Carlo (MC) simulation techniques are becoming very common in the Medical Physicists community. MC can be used for modeling Single Photon Emission Computed Tomography (SPECT) and for dosimetry calculations. 188Re, is a promising candidate for radiotherapeutic production and understanding the mechanisms of the radioresponse of tumor cells "in vitro" is of crucial importance as a first step before "in vivo" studies. The dosimetry of 188Re, used to target different lines of cancer cells, has been evaluated by the MC code GEANT4. The simulations estimate the average energy deposition/per event in the biological samples. The development of prototypes for medical imaging, based on LaBr3:Ce scintillation crystals coupled with a position sensitive photomultiplier, have been studied using GEANT4 simulations. Having tested, in the simulation, surface treatments different from the one applied to the crystal used in our experimental measurements, we found out that the Energy Resolution (ER) and the Spatial Resolution (SR) could be improved, in principle, by machining in a different way the lateral surfaces of the crystal. We have then studied a system able to acquire both echographic and scintigraphic images to let the medical operator obtain the complete anatomic and functional information for tumor diagnosis. The scintigraphic part of the detector is simulated by GEANT4 and first attempts to reconstruct tomographic images have been made using as method of reconstruction a back-projection standard algorithm. The proposed camera is based on slant collimators and LaBr3:Ce crystals. Within the Field of View (FOV) of the camera, it possible to distinguish point sources located in air at a distance of about 2 cm from each other. In particular conditions of uptake, tumor depth and dimension, the preliminary results show that the Signal to Noise Ratio (SNR) values obtained are higher than the standard detection limit.
Resumo:
In this thesis the performances of the CMS Drift Tubes Local Trigger System of the CMS detector are studied. CMS is one of the general purpose experiments that will operate at the Large Hadron Collider at CERN. Results from data collected during the Cosmic Run At Four Tesla (CRAFT) commissioning exercise, a globally coordinated run period where the full experiment was involved and configured to detect cosmic rays crossing the CMS cavern, are presented. These include analyses on the precision and accuracy of the trigger reconstruction mechanism and measurement of the trigger efficiency. The description of a method to perform system synchronization is also reported, together with a comparison of the outcomes of trigger electronics and its software emulator code.
Resumo:
To date the hospital radiological workflow is completing a transition from analog to digital technology. Since the X-rays digital detection technologies have become mature, hospitals are trading on the natural devices turnover to replace the conventional screen film devices with digital ones. The transition process is complex and involves not just the equipment replacement but also new arrangements for image transmission, display (and reporting) and storage. This work is focused on 2D digital detector’s characterization with a concern to specific clinical application; the systems features linked to the image quality are analyzed to assess the clinical performances, the conversion efficiency, and the minimum dose necessary to get an acceptable image. The first section overviews the digital detector technologies focusing on the recent and promising technological developments. The second section contains a description of the characterization methods considered in this thesis categorized in physical, psychophysical and clinical; theory, models and procedures are described as well. The third section contains a set of characterizations performed on new equipments that appears to be some of the most advanced technologies available to date. The fourth section deals with some procedures and schemes employed for quality assurance programs.
Resumo:
The surprising discovery of the X(3872) resonance by the Belle experiment in 2003, and subsequent confirmation by BaBar, CDF and D0, opened up a new chapter of QCD studies and puzzles. Since then, detailed experimental and theoretical studies have been performed in attempt to determine and explain the proprieties of this state. Since the end of 2009 the world’s largest and highest-energy particle accelerator, the Large Hadron Collider (LHC), started its operations at the CERN laboratories in Geneva. One of the main experiments at LHC is CMS (Compact Muon Solenoid), a general purpose detector projected to address a wide range of physical phenomena, in particular the search of the Higgs boson, the only still unconfirmed element of the Standard Model (SM) of particle interactions and, new physics beyond the SM itself. Even if CMS has been designed to study high energy events, it’s high resolution central tracker and superior muon spectrometer made it an optimal tool to study the X(3872) state. In this thesis are presented the results of a series of study on the X(3872) state performed with the CMS experiment. Already with the first year worth of data, a clear peak for the X(3872) has been identified, and the measurement of the cross section ratio with respect to the Psi(2S) has been performed. With the increased statistic collected during 2011 it has been possible to study, in bins of transverse momentum, the cross section ratio between X(3872) and Psi(2S) and separate their prompt and non-prompt component.
Resumo:
One of the main targets of the CMS experiment is to search for the Standard Model Higgs boson. The 4-lepton channel (from the Higgs decay h->ZZ->4l, l = e,mu) is one of the most promising. The analysis is based on the identification of two opposite-sign, same-flavor lepton pairs: leptons are required to be isolated and to come from the same primary vertex. The Higgs would be statistically revealed by the presence of a resonance peak in the 4-lepton invariant mass distribution. The 4-lepton analysis at CMS is presented, spanning on its most important aspects: lepton identification, variables of isolation, impact parameter, kinematics, event selection, background control and statistical analysis of results. The search leads to an evidence for a signal presence with a statistical significance of more than four standard deviations. The excess of data, with respect to the background-only predictions, indicates the presence of a new boson, with a mass of about 126 GeV/c2 , decaying to two Z bosons, whose characteristics are compatible with the SM Higgs ones.
Resumo:
In this thesis, my work in the Compact Muon Solenoid (CMS) experiment on the search for the neutral Minimal Supersymmetric Standard Model (MSSM) Higgs decaying into two muons is presented. The search is performed on the full data collected during the years 2011 and 2012 by CMS in proton-proton collisions at CERN Large Hadron Collider (LHC). The MSSM is explored within the most conservative benchmark scenario, m_h^{max}, and within its modified versions, m_h^{mod +} and m_h^{mod -}. The search is sensitive to MSSM Higgs boson production in association with a b\bar{b} quark pair and to the gluon-gluon fusion process. In the m_h^{max} scenario, the results exclude values of tanB larger than 15 in the m_A range 115-200 GeV, and values of tanB greater than 30 in the m_A range up to 300 GeV. There are no significant differences in the results obtained within the three different scenarios considered. Comparisons with other neutral MSSM Higgs searches are shown.
Resumo:
In the context of increasing beam energy and luminosity of the LHC accelerator at CERN, it will be important to accurately measure the Machine Induced Background. A new monitoring system will be installed in the CMS cavern for measuring the beam background at high radius. This detector, called the Beam Halo Monitor, will provide an online, bunch-by-bunch measurement of background induced by beam halo interactions, separately for each beam. The detector is composed of synthetic quartz Cherenkov radiators, coupled to fast UV sensitive photomultiplier tubes. The directional and fast response of the system allows the discrimination of the background particles from the dominant flux in the cavern induced by pp collision debris, produced within the 25 ns bunch spacing. The readout electronics of this detector will make use of many components developed for the upgrade of the CMS Hadron Calorimeter electronics, with a dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal will be digitized by a charge integrating ASIC, providing both the signal rise time and the charge integrated over one bunch crossing. The backend electronics will record bunch-by-bunch histograms, which will be published to CMS and the LHC using the newly designed CMS beam instrumentation specific DAQ. A calibration and monitoring system has been designed to generate triggered pulses of UV light to monitor the efficiency of the system. The experimental results validating the design of the detector, the calibration system and the electronics will be presented.