7 resultados para CATHODIC ELECTROCHEMILUMINESCENCE
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
The study of electrochemiluminescence (ECL) involves photophysical and electrochemical aspects. Excited states are populated by an electrical stimulus. The most important applications are in the diagnostic field where a number of different biologically-relevant molecules (e.g. proteins and nucleic acids) can be recognized and quantified with a sensitivity and specificity previously not reachable. As a matter of fact the electrochemistry, differently to the classic techniques as fluorescence and chemiluminescence, allows to control the excited state generation spatially and temporally. The two research visits into A. J. Bard electrochemistry laboratories were priceless. Dr. Bard has been one of ECL pioneers, the first to introduce the technique and the one who discovered in 1972 the surprising emission of Ru(bpy)3 2+. I consider necessary to thank by now my supervisors Massimo and Francesco for their help and for giving me the great opportunity to know this unique science man that made me feel enthusiastic. I will never be grateful enough… Considering that the experimental techniques of ECL did not changed significantly in these last years the most convenient research direction has been the developing of materials with new or improved properties. In Chapter I the basics concepts and mechanisms of ECL are introduced so that the successive experiments can be easily understood. In the final paragraph the scopes of the thesis are briefly described. In Chapter II by starting from ECL experimental apparatus of Dr. Bard’s laboratories the design, assembly and preliminary tests of the new Bologna instrument are carefully described. The instrument assembly required to work hard but resulted in the introduction of the new technique in our labs by allowing the continuation of the ECL studies began in Texas. In Chapter III are described the results of electrochemical and ECL studies performed on new synthesized Ru(II) complexes containing tetrazolate based ligands. ECL emission has been investigated in solution and in solid thin films. The effect of the chemical protonation of the tetrazolate ring on ECL emission has been also investigated evidencing the possibility of a catalytic effect (generation of molecular hydrogen) of one of the complexes in organic media. Finally, after a series of preliminary studies on ECL emission in acqueous buffers, the direct interaction with calf thymus DNA of some complexes has been tested by ECL and photoluminescence (PL) titration. In Chapter IV different Ir(III) complexes have been characterized electrochemically and photophysically (ECL and PL). Some complexes were already well-known in literature for their high quantum efficiency whereas the remaining were new synthesized compounds containing tetrazolate based ligands analogous to those investigated in Chapt. III. During the tests on a halogenated complex was unexpectedly evidenced the possibility to follow the kinetics of an electro-induced chemical reaction by using ECL signal. In the last chapter (V) the possibility to use mono-use silicon chips electrodes as ECL analitycal devices is under investigation. The chapter begins by describing the chip structure and materials then a signal reproducibility study and geometry optimization is carried on by using two different complexes. In the following paragraphs is reported in detail the synthesis of an ECL label based on Ru(bpy)3 2+ and the chip functionalization by using a lipoic acid SAM and the same label. After some preliminary characterizations (mass spectroscopy TOF) has been demonstrated that by mean of a simple and fast ECL measurement it’s possible to confirm the presence of the coupling product SAM-label into the chip with a very high sensitivity. No signal was detected from the same system by using photoluminescence.
Resumo:
Biomarkers are biological indicators of human health conditions. Their ultra-sensitive quantification is of paramount importance in clinical monitoring and early disease diagnosis. Biosensors are simple and easy-to-use analytical devices and, in their world, electrochemiluminescence (ECL) is one of the most promising analytical techniques that needs an ever-increasing sensitivity for improving its clinical effectiveness. Scope of this project was the investigation of the ECL generation mechanisms for enhancing the ECL intensity also through the identification of suitable nanostructures. The combination of nanotechnologies, microscopy and ECL has proved to be a very successful strategy to improve the analytical efficiency of ECL in one of its most promising bioanalytical approaches, the bead-based immunoassay. Nanosystems, such as [Ru(bpy)3]2+-dye-doped nanoparticles (DDSNPs) and Bodipy Carbon Nanodots, have been used to improve the sensitivity of ECL techniques thanks to their advantageous and tuneable properties, reaching a signal increase of 750% in DDSNPs-bead-based immunoassay system. In this thesis, an investigation of size and distance effects on the ECL mechanisms was carried out through the innovative combination of ECL microscopy and electrochemical mapping of radicals. It allowed the discovery of an unexpected and highly efficient mechanistic path for ECL generation at small distances from the electrode surface. It was exploited and enhanced through the addition of a branched amine DPIBA to the usual coreactant TPrA solution for enhancing the ECL efficiency until a maximum of 128%. Finally, a beads-based immunoassay and an immunosensor specific for cardiac Troponin I were built exploiting previous results and carbon nanotubes features. They created a conductive layer around beads enhancing the signal by 70% and activating an ECL mechanism unobserved before in such systems. In conclusion, the combination of ECL microscopy and nanotechnology and the deep understanding of the mechanisms responsible for the ECL emission led to a great enhancement in the signal.
Resumo:
Biomarkers are biological indicators of human health conditions. Their ultra-sensitive quantification is of cardinal importance in clinical monitoring and early disease diagnosis. Biosensors are some worldwide simple and easy-to-use analytical devices as a matter of fact, biosensors using electrochemiluminescence (ECL) are one of the most promising biosensors that needs an ever-increasing sensitivity for improving its clinical effectiveness. The principal aspiration of this project is the investigation of the ECL generation mechanisms for enhancing the ECL intensity and the development of an ultrasensitive sensor, the use of metal-oxide materials (Mox) and the substitution of metal-free dyes. Novel dyes such as BODIPY, TADF are used to improve the sensitivity of ECL techniques thanks to their advantageous and tunable properties, enhancing the signal and also the ECL efficiency. Additionally, the use of Mox could be beneficial for the investigation of two different ECL mechanisms, which occur simultaneously. In this thesis, the investigation of size and distance effects on electrochemical (EC) mechanisms was carried out through the innovative combination of a standard detection system using different size of micromagnetic beads (MBs). That allowed the discovery of an unexpected and highly efficient mechanistic path for electrochemical generation at small distances from the electrode’s surface. The smallest MBs (0.1μm) demostrate an enhancement of electrochemical signal than the bigger one (2.8μm) until 4 times of magnitude. Finally, a novel ultrasensitive sensor, based on the coreactant-luminophores mechanism, was developed for the determination of whole viral genome specific for cardiac HBV and COVID-19 virus. In conclusion, the ECL and the use of EC techniques (such as amperometry), improved the understanding of mechanisms responsible for the ECL/EC signal led to a great enhancement in the signal.
Sviluppo di biosensori: modifiche di superfici elettrodiche e sistemi di immobilizzazione enzimatica
Resumo:
An amperometric glucose biosensor was developed using an anionic clay matrix (LDH) as enzyme support. The enzyme glucose oxidase (GOx) was immobilized on a layered double hydroxide Ni/Al-NO3 LDH during the electrosynthesis, which was followed by crosslinking with glutaraldehyde (GA) vapours or with GA and bovine serum albumin (GABSA) to avoid the enzyme release. The electrochemical reaction was carried out potentiostatically, at -0.9V vs. SCE, using a rotating disc Pt electrode to assure homogeneity of the electrodeposition suspension, containing GOx, Ni(NO3)2 and Al(NO3)3 in 0.3 M KNO3. The mechanism responsible of the LDH electrodeposition involves the precipitation of the LDH due to the increase of pH at the surface of the electrode, following the cathodic reduction of nitrates. The Pt surface modified with the Ni/Al-NO3 LDH shows a much reduced noise, giving rise to a better signal to noise ratio for the currents relative to H2O2 oxidation, and a linear range for H2O2 determination wider than the one observed for bare Pt electrodes. We pointed out the performances of the biosensor in terms of sensitivity to glucose, calculated from the slope of the linear part of the calibration curve for enzimatically produced H2O2; the sensitivity was dependent on parameters related to the electrodeposition in addition to working conditions. In order to optimise the glucose biosensor performances, with a reduced number of experimental runs, we applied an experimental design. A first screening was performed considering the following variables: deposition time (30 - 120 s), enzyme concentration (0.5 - 3.0 mg/mL), Ni/Al molar ratio (3:1 or 2:1) of the electrodeposition solution at a total metals concentration of 0.03 M and pH of the working buffer solution (5.5-7.0). On the basis of the results from this screening, a full factorial design was carried out, taking into account only enzyme concentration and Ni/Al molar ratio of the electrosynthesis solution. A full factorial design was performed to study linear interactions between factors and their quadratic effects and the optimal setup was evaluated by the isoresponse curves. The significant factors were: enzyme concentration (linear and quadratic terms) and the interaction between enzyme concentration and Ni/Al molar ratio. Since the major obstacle for application of amperometric glucose biosensors is the interference signal resulting from other electro-oxidizable species present in the real matrices, such as ascorbate (AA), the use of different permselective membranes on Pt-LDHGOx modified electrode was discussed with the aim of improving biosensor selectivity and stability. Conventional membranes obtained using Nafion, glutaraldehyde (GA) vapours, GA-BSA were tested together with more innovative materials like palladium hexacyanoferrate (PdHCF) and titania hydrogels. Particular attention has been devoted to hydrogels, because they possess some attractive features, which are generally considered to favour biosensor materials biocompatibility and, consequently, the functional enzyme stability. The Pt-LDH-GOx-PdHCF hydrogel biosensor presented an anti-interferant ability so that to be applied for an accurate glucose analysis in blood. To further improve the biosensor selectivity, protective membranes containing horseradish peroxidase (HRP) were also investigated with the aim of oxidising the interferants before they reach the electrode surface. In such a case glucose determination was also accomplished in real matrices with high AA content. Furthermore, the application of a LDH containing nickel in the oxidised state was performed not only as a support for the enzyme, but also as anti-interferant sistem. The result is very promising and it could be the starting point for further applications in the field of amperometric biosensors; the study could be extended to other oxidase enzymes.
Resumo:
The present PhD project was focused on the development of new tools and methods for luminescence-based techniques. In particular, the ultimate goal was to present substantial improvements to the currently available technologies for both research and diagnostic in the fields of biology, proteomics and genomics. Different aspects and problems were investigated, requiring different strategies and approaches. The whole work was thus divided into separate chapters, each based on the study of one specific aspect of luminescence: Chemiluminescence, Fluorescence and Electrochemiluminescence. CHAPTER 1, Chemiluminescence The work on luminol-enhancer solution lead to a new luminol solution formulation with 1 order of magnitude lower detection limit for HRP. This technology was patented with Cyanagen brand and is now sold worldwide for Western Blot and ELISA applications. CHAPTER 2, Fluorescescence The work on dyed-doped silica nanoparticles is marking a new milestone in the development of nanotechnologies for biological applications. While the project is still in progress, preliminary studies on model structures are leading to very promising results. The improved brightness of these nano-sized objects, their simple synthesis and handling, their low toxicity will soon turn them, we strongly believe, into a new generation of fluorescent labels for many applications. CHAPTER 3, Electrochemiluminescence The work on electrochemiluminescence produced interesting results that can potentially turn into great improvements from an analytical point of view. Ru(bpy)3 derivatives were employed both for on-chip microarray (Chapter 3.1) and for microscopic imaging applications (Chapter 3.2). The development of these new techniques is still under investigation, but the obtained results confirm the possibility to achieve the final goal. Furthermore the development of new ECL-active species (Chapter 3.3, 3.4, 3.5) and their use in these applications can significantly improve overall performances, thus helping to spread ECL as powerful analytical tool for routinary techniques. To conclude, the results obtained are of strong value to largely increase the sensitivity of luminescence techniques, thus fulfilling the expectation we had at the beginning of this research work.
Resumo:
In this research work the optimization of the electrochemical system of LDHs as catalytic precursors on FeCrAlY foams was carried out. Preliminary sintheses were performed on flat surfaces in order to easily characterize the deposited material. From the study of pH evolution vs time at different cathodic potentials applied to a Pt electrode, the theoretical best working conditions for the synthesis of single hydroxides and LDH compounds was achieved. In order to define the optimal potential for the synthesis of a particular LDH compound, the collected data were compared with the interval of precipitation determined by titration with NaOH. However, the characterization of the deposited material on Pt surfaces did not confirm the deposition of a pure and homogeneous LDH phase during the synthesis. Instead a sequential deposition linked to the pH of precipitation of the involved elements is observed. The same behavior was observed during the synthesis of the RhMgAl LDH on FeCrAlY foam as catalytic precursor. Several parameters were considered in order to optimize the synthesis.. The development of electrochemical cells with different feature, such as the counter electrode dimensions or the contact between the foam and the potentiostat, had been carried out in order to obtain a better coating of the foam. The influence of the initial pH of the electrolyte solution, of the applied potential, of the composition of the electrolytic solution were investigated in order to improve a better coating of the catalyst support. Catalytic tests were performed after the calcination of the deposited foam for the CPO and SR reactions, showing an improve of performances along with optimization of the precursors synthesis conditions.
Resumo:
Noise is constant presence in measurements. Its origin is related to the microscopic properties of matter. Since the seminal work of Brown in 1828, the study of stochastic processes has gained an increasing interest with the development of new mathematical and analytical tools. In the last decades, the central role that noise plays in chemical and physiological processes has become recognized. The dual role of noise as nuisance/resource pushes towards the development of new decomposition techniques that divide a signal into its deterministic and stochastic components. In this thesis I show how methods based on Singular Spectrum Analysis have the right properties to fulfil the previously mentioned requirement. During my work I applied SSA to different signals of interest in chemistry: I developed a novel iterative procedure for the denoising of powder X-ray diffractograms; I “denoised” bi-dimensional images from experiments of electrochemiluminescence imaging of micro-beads obtaining new insight on ECL mechanism. I also used Principal Component Analysis to investigate the relationship between brain electrophysiological signals and voice emission.