10 resultados para Aortic regurgitation

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Survival of patients with Acute Aortic Syndrome (AAS) may relate to the speed of diagnosis. Diagnostic delay is exacerbated by non classical presentations such as myocardial ischemia or acute heart failure (AHF). However little is known about clinical implications and pathophysiological mechanisms of Troponin T elevation and AHF in AAS. Methods and Results: Data were collected from a prospective metropolitan AAS registry (398 patients diagnosed between 2000 and 2013). Troponin T values (either standard or high sensitivity assay, HS) were available in 248 patients (60%) of the registry population; the overall frequency of troponin positivity was 28% (ranging from 16% to 54%, using standard or HS assay respectively, p = 0.001). Troponin positivity was associated with a twofold increased risk of long in-hospital diagnostic time (OR 1.92, 95% CI 1.05-3.52, p = 0.03), but not with in-hospital mortality. The combination of positive troponin and ACS-like ECG abnormalities resulted in a significantly increased risk of inappropriate therapy due to a misdiagnosis of ACS (OR 2.48, 95% CI 1.12-5.54, p = 0.02). Patients with AHF were identified by the presence of dyspnea as presentation symptom or radiological signs of pulmonary congestion or cardiogenic shock. The overall frequency of AHF was 28 % (32% type A vs. 20% type B AAS, p = 0.01). AHF was due to a variety of pathophysiological mechanisms including cardiac tamponade (26%), aortic regurgitation (25%), myocardial ischemia (17%), hypertensive crisis (10%). AHF was associated with increased surgical delay and with increased risk of in-hospital death (adjusted OR 1.97 95% CI1.13-3.37,p=0.01). Conclusions: Troponin positivity (particularly HS) was a frequent finding in AAS. Abnormal troponin values were strongly associated with ACS-like ECG findings, in-hospital diagnostic delay, and inappropriate therapy. AHF was associated with increased surgical delay and was an independent predictor of in-hospital mortality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. A sizable group of patients with symptomatic aortic stenosis (AS) can undergo neither surgical aortic valve replacement (AVR) nor transcatheter aortic valve implantation (TAVI) because of clinical contraindications. The aim of this study was to assess the potential role of balloon aortic valvuloplasty (BAV) as a “bridge-to-decision” in selected patients with severe AS and potentially reversible contraindications to definitive treatment. Methods. We retrospectively enrolled 645 patients who underwent first BAV at our Institution between July 2007 and December 2012. Of these, the 202 patients (31.2%) who underwent BAV as bridge-to-decision (BTD) requiring clinical re-evaluation represented our study population. BTD patients were further subdivided in 5 groups: low left ventricular ejection fraction; mitral regurgitation grade ≥3; frailty; hemodynamic instability; comorbidity. The main objective of the study was to evaluate how BAV influenced the final treatment strategy in the whole BTD group and in its single specific subgroups. Results. Mean logistic EuroSCORE was 23.5±15.3%, mean age was 81±7 years. Mean transaortic gradient decreased from 47±17 mmHg to 33±14 mmHg. Of the 193 patients with BTD-BAV who received a second heart team evaluation, 72.5% were finally deemed eligible for definitive treatment (25.4%for AVR; 47.2% for TAVI): respectively, 96.7% of patients with left ventricular ejection fraction recovery; 70.5% of patients with mitral regurgitation reduction; 75.7% of patients who underwent BAV in clinical hemodynamic instability; 69.2% of frail patients and 68% of patients who presented relevant comorbidities. 27.5% of the study population was deemed ineligible for definitive treatment and treated with standard therapy/repeated BAV. In-hospital mortality was 4.5%, cerebrovascular accident occurred in 1% and overall vascular complications were 4% (0.5% major; 3.5% minor). Conclusions. Balloon aortic valvuloplasty should be considered as bridge-to-decision in high-risk patients with severe aortic stenosis who cannot be immediate candidates for definitive percutaneous or surgical treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Echocardiography is the standard clinical approach for quantification of the severity of aortic stenosis (AS). A comprehensive examination of its overall reproducibility and the simultaneous estimation of its variance components by multiple operators, readers, probe applications, and beats have not been undertaken. METHOD AND RESULTS Twenty-seven subjects with AS were scanned over 7 months in the echo-department by a median of 3 different operators. From each patient and each operator multiple runs of beats from multiple probe positions were stored for later analysis by multiple readers. The coefficient of variation was 13.3%, 15.9%, 17.6%, and 20.2% for the aortic peak velocity (Vmax), and velocity time integral (VTI), and left ventricular outflow tract (LVOT) Vmax and VTI respectively. The largest individual contributors to the overall variability were the beat-to-beat variability (9.0%, 9.3%, 9.5%, 9.4% respectively) and that of inability of an individual operator to precisely apply the probe to the same position twice (8.3%, 9.4%, 12.9%, 10.7% respectively). The tracing (inter-reader) and reader (inter-reader), and operator (inter-operator) contribution were less important. CONCLUSIONS Reproducibility of measurements in AS is poorer than often reported in the literature. The source of this variability does not appear, as traditionally believed, to result from a lack of training or operator and reader specific factors. Rather the unavoidable beat-to-beat biological variability, and the inherent impossibility of applying the ultrasound probe in exactly the same position each time are the largest contributors. Consequently, guidelines suggesting greater standardisation of procedures and further training for sonographers are unlikely to result in an improvement in precision. Clinicians themselves should be wary of relying on even three-beat averages as their expected coefficient of variance is 10.3% for the peak velocity at the aortic valve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Ageing and inflammation are critical for the occurrence of aortic diseases. Extensive inflammatory infiltrate and excessive ECM proteloysis, mediated by MMPs, are typical features of abdominal aortic aneurysm (AAA). Mesenchymal Stromal Cells (MSCs) have been detected within the vascular wall and represent attractive candidates for regenerative medicine, in virtue of mesodermal lineage differentiation and immunomodulatory activity. Meanwhile, many works have underlined an impaired MSC behaviour under pathological conditions. This study was aimed to define a potential role of vascular MSCs to AAA development. Methods. Aortic tissues were collected from AAA patients and healthy donors. Our analysis was organized on three levels: 1) histology of AAA wall; 2) detection of MSCs and evaluation of MMP-9 expression on AAA tissue; 3) MSC isolation from AAA wall and characterization for mesenchymal/stemness markers, MMP-2, MMP-9, TIMP-1, TIMP-2 and EMMPRIN. AAA-MSCs were tested for immunomodulation, when cultured together with activated peripheral blood mononuclear cells (PBMCs). In addition, a co-colture of both healthy and AAA MSCs was assessed and afterwards MMP-2/9 mRNA levels were analyzed. Results. AAA-MSCs showed basic mesenchymal properties: fibroblastic shape, MSC antigens, stemness genes. MMP-9 mRNA, protein and enzymatic activity were significantly increased in AAA-MSCs. Moreover, AAA-MSCs displayed a weak immunosuppressive activity, as shown by PBMC ongoing along cell cycle. MMP-9 was shown to be modulated at the transcriptional level through the direct contact as well as the paracrine action of healthy MSCs. Discussion. Vascular injury did not affect the MSC basic phenotype, but altered their function, a increased MMP-9 expression and ineffective immunmodulation. These data suggest that vascular MSCs can contribute to aortic disease. In this view, the study of key processes to restore MSC immunomodulation could be relevant to find a pharmacological approach for monitoring the aneurysm progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives CO2-EVAR was proposed for treatment of AAA especially in patients with CKD. Issues regarding standardization, such as visualization of lowest renal artery (LoRA) and quality image in angiographies performed from pigtail or introducer-sheath, are still unsolved. Aim of the study was to analyze different steps of CO2-EVAR to create an operative protocol to standardize the procedure. Methods Patients undergoing CO2-EVAR were prospectively enrolled in 5 European centers (2018-2021). CO2-EVAR was performed using an automated injector. LoRA visualization and image quality (1-4) were analyzed and compared at different procedure steps: preoperative CO2-angiography from Pigtail/Introducer-sheath (1st Step), angiographies from Pigtail at 0%,50%,100% main body (MB) deployment (2nd Step), contralateral hypogastric artery (CHA) visualization with CO2 injection from femoral Introducer-sheath (3rd Step) and completion angiogram from Pigtail/Introducer-sheath (4th Step). Intra-/postoperative adverse events were evaluated. Results Sixty-five patients undergoing CO2-EVAR were enrolled, 55/65(84.5%) male, median age 75(11.5) years. Median ICM was 20(54)cc; 19/65(29.2%) procedures were performed with 0-iodine. 1st Step: median image quality was significantly higher with CO2 injected from femoral introducer [Pigtail2(3)vs.3(3)Introducer,p=.008]. 2nd Step: LoRA was more frequently detected at 50% (93%vs.73.2%, p=.002) and 100% (94.1%vs.78.4%, p=.01) of MB deployment compared with first angiography from Pigtail; image quality was significantly higher at 50% [3(3)vs.2(3),p=<.001] and 100% [4(3) vs.2(3),p=.001] of MB deployment. CHA was detected in 93% cases (3rd Step). Mean image quality was significantly higher when final angiogram (4th Step) was performed from introducer (Pigtail2.6±1.1vs.3.1±0.9Introducer,p=<.001). Rates of intra-/postoperative adverse events (pain,vomit,diarrhea) were 7.7% and 12.5%. Conclusions Preimplant CO2-angiography should be performed from Introducer-sheath. MB steric bulk during its deployment should be used to improve image quality and LoRA visualization with CO2. CHA can be satisfactorily visualized with CO2. Completion CO2-angiogram should be performed from femoral Introducer-sheath. This operative protocol allows to perform CO2-EVAR with minimal ICM and low rate of mild complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Endograft deployment is a well-known cause of arterial stiffness increase as well as arterial stiffness increase represent a recognized cardiovascular risk factor. A harmful effect on cardiac function induced by the endograft deployment should be investigated. Aim of this study was to evaluate the impact of endograft deployment on the arterial stiffness and cardiac geometry of patients treated for aortic aneurysm in order to detect modifications that could justify an increased cardiac mortality at follow-up. MATHERIALS AND METHODS Over a period of 3 years, patients undergoing elective EVAR for infrarenal aortic pathologies in two university centers in Emilia Romagna were examined. All patients underwent pre-operative and six-months post-operative Pulse Wave Velocity (PWV) examination using an ultrasound-based method performed by vascular surgeons together with trans-thoracic echocardiography examination in order to evaluate cardiac chambers geometry before and after the treatment. RESULTS 69 patients were enrolled. After 36 months, 36 patients (52%) completed the 6 months follow-up examination.The ultrasound-based carotid-femoral PWV measurements performed preoperatively and 6 months after the procedure revealed a significant postoperative increase of cf-PWV (11,6±3,6 m/sec vs 12,3±8 m/sec; p.value:0,037).Postoperative LVtdV (90±28,3 ml/m2 vs 99,1±29,7 ml/m2; p.value:0.031) LVtdVi (47,4±15,9 ml/m2 vs 51,9±14,9 ml/m2; p.value:0.050), IVStd (12±1,5 mm vs 12,1±1,3 mm; p.value:0,027) were significantly increased if compared with preoperative measures.Postoperative E/A (0,76±0,26 vs 0,6±0,67; p.value:0,011), E’ lateral (9,5±2,6 vs 7,9±2,6; p.value:0,024) and A’ septal (10,8±1,5 vs 8,9±2; p.value0,005) were significantly reduced if compared with preoperative measurements CONCLUSION The endovascular treatment of the abdominal aorta causes an immediate and significant increase of the aortic stiffness.This increase reflects negatively on patients’ cardiac geometry inducing left ventricle hypertrophy and mild diastolic disfunction after just 6 months from endograft’s implantation.Further investigations and long-term results are necessary to access if this negative remodeling could affect the cardiac outcome of patient treated using the endovascular approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Aim of this multicentric study:to compare the short-and mid-term results of bare metal stents(BMS)and covered stents(CS)in the Kissing Stent(KS)technique. METHODS Patients undertaking a KS with BMS or CS between January 2017-August 2021 included. Morphological features of plaques were classified as per the extension of calcifications and thrombosis. Every endpoint and outcome was compared in relation to BMS or CS. All patients included received dual anti-platelets DAPT)for at least one month. RESULTS Thirty-four patients enrolled,17 treated with BMS and 17 with CS. Average age 66 years. The 80% of patients were part of TASC C-D categories. DAPT was administered to 82.4%(28/34)of patients with a mean duration of 4.4±1.6 months. Mean follow-up 32.1±17.8 months. Technical Success was 100%. Immediate Clinical Success was reached in 29 cases(85.3%). Immediate and 30-day Clinical Success was higher in CS(64.7% vs 100%, p=.01). Overall Clinical Success at 1-year follow-up was 91.2%,and resulted significantly higher in CS(82.4% vs 100%,p .04). Overall Primary Patency,Assisted Patency,and Secondary Patency at 30 days were 97.1%,97.1%,and 100%,without differences between BMS and CS(94.1% vs 100%,94.1% vs 100%,and 100% vs 100%;p =.7). Two cases(5.9%)of thrombosis were registered,and both occurred within 3 months after the procedure and both in the BMS,without statistical differences with the CS group(11.8% vs 0%,p .48). Both cases of thrombosis occurred in patients who were not treated with dual antiplatelet therapy(33.3% vs 0%,p .027). Survival statistically differed only at the mean follow-up in favour of CS(70.6% and 100%,p .04). CONCLUSIONS The endovascular approach is currently safe and effective in the treatment of AIOD,and KS offers excellent results in particular if performed with CS; however,no statistically significant differences emerged between the two types of stents in terms of patency,reintervention,and complications. DAPT seems to warrant the best results in terms of patency,although there is still no consensus about the ideal duration of administration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The frozen elephant trunk(FET) technique is one of the last evolution in the treatment of complex pathologies of the aortic arch and the descending thoracic aorta.Materials and methods: Between January 2007 and March 2021, a total of 396 patients underwent total aortic arch replacements with the FET technique in our centre.The main indications were thoracic aortic aneurysm(n=104,28.2%), chronic aortic dissection(n=224,53.4%) and acute aortic dissection(n=68, 18.4%). We divided the population in two groups according the position of the distal anastomosis (zone 2 vs zone 3) and the length of the stent graft (< 150 mm vs > 150 mm): conservative group (Zone 2 anastomosis + stent length < 150mm, n. 140 pts) and aggressive group (zone 3 anastomosis + stent length > 150mm, n. 141). Results: The overall 30-day mortality rate was 13%(48/369); the risk factor analysis showed that an aggressive approach was neither a risk factor for major complication (permanent dialysis, tracheostomy, bowel malperfusion and permanent paraplegia) neither for 30-day mortality. The survival rate at 1, 5,10 and 15 years was 87.7%,75%,61.3% and 58.4% respectively. During the follow up, an aortic reintervention was performed in 122 patients (38%), 5 patients received a non-aortic cardiac surgery. Freedom from aortic reintervention at 1-,5- and 10-year was 77%,54% and 44% respectively. The freedom from aortic reintervention was higher in the ‘aggressive’ group (62.5%vs40.0% at 5 years, log-rank=0.056). An aggressive approach was not protective for aortic reintervention at follow up and for death at follow up. Conclusions: The FET technique represents a feasible and efficient option in the treatment of complex thoracic aortic pathologies. An aortic reintervention after FET is very common and the decision-making approach should consider and balance the higher risk of an aggressive approach in terms of post-operative complication versus the higher risk of a second aortic reintervention at follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to evaluate if spinal cord ischemia (SCI), especially its late presentation, and can be correlated to the results of intraoperative evoked potential monitoring (IOM). Methods. This study is a physician-initiated, retrospective, single-center, non-randomized study. Data from all patients undergoing a thoracoabdominal aortic aneurysm surgical repair (TAAA SR) between January 2016 and March 2020 IOM was collected and analyzed. Results. During the study period, 261 patients underwent TAAA SR with MEP/SSEPs monitoring [190 males, 73%; median age 65 (57-71)]. Thirty-seven patients suffered from SCI, for an overall rate of 14% (permanent 9%). When stratifying patients according to the SCI onset, 18 patients presented with an early (11 permanent) and 19 with a late SCI (<24h) (11 permanent). Of 261 patients undergoing TAAA SR with IOM, 15 were excluded due to changes in the upper extremity motor evoked potentials. For the remaining 246, the association between SCI and IOM was investigated: only irreversible IOM loss without peripheral changes have been found to be a risk factor for late onset SCI (p=.006). Furthermore, given that no statistical differences were found between the two groups when no IOM changes were recorded (p=.679), this situation cannot reliably rule out any SCI in our cohort. Independent risk factors for late spinal cord ischemia onset found at multivariate analysis were smoking history (p=.008), BMI>28 (p=.048) and TAAA extent II (p=.009). The irreversible MEP change without peripheral showed a trend of significance (p=.052). Conclusions. Evoked potential intraoperative monitoring is an important adjunct during thoracoabdominal aortic open repair to predict and possibly prevent spinal cord ischemia. Irreversible IOM loss without peripheral changes was predictive of late SCI, therefore more attention should be paid to the postoperative management of this subgroup of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdominal aortic aneurysm is the pathological dilation of the abdominal tract of the aorta and, if left untreated, could undergo rupture with a mortality rate of up to 90%. EVAR is the most common method for AAA treatment consisting in the internal coverage of the aorta with a metallic stent to isolate the aneurysmatic segment from the systemic circulation. Although EVAR technical success rate is high, reinterventions are common. Among the causes of reinterventions typeII endoleaks are the most frequent and consist in retrograde blood flow into the aneurysmal sac from collateral aortic branches. Continued perfusion of the aneurysm sac may lead to aneurysm rupture, therefore AAA sac embolization is performed using metallic coils. However, the presence of artifacts caused by the presence of metallic coils is a limitation because they are radiopaque and can hamper the endoleak during imaging follow-up. This study is aimed at developing a biocompatible hydrogel that could be injected into the aneurysmal sac and may allow a selective intraprocedural sac embolization to reduce post procedural typeII endoleak and eventual AAA rupture. P(BT75BSI25) was synthesized by polycondensation and its biocompatibility tested to assess whether the polymers had no toxic effects. HUVEC cell line was used to mimic the environment in which the polymer would be in contact with, PBS was used as a positive control and MTT assay was performed to evaluate cellular viability after being in contact with the hydrogel. MTT assay showed no significant difference between PBS and P(BT75BSI25), thus the polymer is biocompatible, as confirmed by the analysis of apoptosis by flow cytometry. An aromatic copolymer was obtained via polycondensation and was found to be biocompatible in contact with endothelial cells. This suggests that the hydrogel could be potentially used in the clinical setting for the treatment of type II endoleak after EVAR.