8 resultados para Angioplasty, Balloon
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
Background: Balloon pulmonary angioplasty (BPA) has recently been developed as an alternative and less- invasive treatment strategy for chronic thromboembolic pulmonary hypertension (CTEPH), but therapeutic efficacy and technical safety of the technique have to be established. Aim: effects of BPA on patients with inoperable disease or residual pulmonary hypertension (PH) after pulmonary endarterectomy (PEA). Methods: From June 2015 to September 2019 we enrolled symptomatic (NYHA ≥ II) inoperable CTEPH patients and patients with residual PH after PEA. At baseline, immediately before the first BPA session and 3-6 months after last BPA session all patients underwent clinical evaluation, six-minute walking distance and right heart catheterization. For comparisons Friedman test (with Bonferroni post-hoc pairwise analysis) was used. Survival curves were done with Kaplan Meier method. Results: Forty-seven patients [male 45%, median age 68 (51-74) years, 40 inoperable and 7 with residual PH after PEA] were treated for a total of 136 sessions (median number of sessions for each patient: 2); during each session we treated 2 (2-3) vessels; BPA significantly improved symptoms (NYHA III-IV from 85 to 42%), exercise capacity (from 425 to 446 m) and hemodynamic profile (reduction of mean pulmonary arterial pressure from 41 to 35 mmHg and of pulmonary vascular resistance from 7.1 to 4.7 WU). Five pulmonary artery dissection and 2 hemoptysis with clinical impairment were documented; 33 patients had lung injury (radiographic opacity with/without hemoptysis and/or hypoxemia), 7 patients had access site complications. Five patients died during follow-up (none within 30 days from the procedure) because of sepsis (1), heart failure (1), cancer (1), arrhythmic storm (1) and sudden death in a patient with severe coronary atherosclerosis (1). Conclusions: BPA is a safe and effective treatment able to improve symptoms and hemodynamic profile in inoperable CTEPH patients and in patients with residual PH after PEA.
Resumo:
Background. A sizable group of patients with symptomatic aortic stenosis (AS) can undergo neither surgical aortic valve replacement (AVR) nor transcatheter aortic valve implantation (TAVI) because of clinical contraindications. The aim of this study was to assess the potential role of balloon aortic valvuloplasty (BAV) as a “bridge-to-decision” in selected patients with severe AS and potentially reversible contraindications to definitive treatment. Methods. We retrospectively enrolled 645 patients who underwent first BAV at our Institution between July 2007 and December 2012. Of these, the 202 patients (31.2%) who underwent BAV as bridge-to-decision (BTD) requiring clinical re-evaluation represented our study population. BTD patients were further subdivided in 5 groups: low left ventricular ejection fraction; mitral regurgitation grade ≥3; frailty; hemodynamic instability; comorbidity. The main objective of the study was to evaluate how BAV influenced the final treatment strategy in the whole BTD group and in its single specific subgroups. Results. Mean logistic EuroSCORE was 23.5±15.3%, mean age was 81±7 years. Mean transaortic gradient decreased from 47±17 mmHg to 33±14 mmHg. Of the 193 patients with BTD-BAV who received a second heart team evaluation, 72.5% were finally deemed eligible for definitive treatment (25.4%for AVR; 47.2% for TAVI): respectively, 96.7% of patients with left ventricular ejection fraction recovery; 70.5% of patients with mitral regurgitation reduction; 75.7% of patients who underwent BAV in clinical hemodynamic instability; 69.2% of frail patients and 68% of patients who presented relevant comorbidities. 27.5% of the study population was deemed ineligible for definitive treatment and treated with standard therapy/repeated BAV. In-hospital mortality was 4.5%, cerebrovascular accident occurred in 1% and overall vascular complications were 4% (0.5% major; 3.5% minor). Conclusions. Balloon aortic valvuloplasty should be considered as bridge-to-decision in high-risk patients with severe aortic stenosis who cannot be immediate candidates for definitive percutaneous or surgical treatment.
Resumo:
L'endoarteriectomia polmonare (PEA) rappresenta la terapia più efficace per il cuore polmonare cronico tromboembolico (CTEPH). Tuttavia, una quota sostanziale di pazienti sono non operabili ma hanno altre possibili strategie di trattamento: terapia medica e angioplastica polmonare(BPA). In questo studio abbiamo confrontato l'efficacia delle diverse strategie di trattamento del CTEPH nel mondo reale. Metodi: Sono stati inclusi tutti i pazienti con CTEPH riferiti al nostro centro. Abbiamo valutato l'efficacia della terapia medica a breve termine sui dati clinici, funzionali, capacità di esercizio e profilo emodinamico (indipendentemente dalle strategie di trattamento successive), l'efficacia di PEA e BPA (indipendentemente dalle strategie di trattamento precedenti/successive); Abbiamo inoltre riportato l'efficacia a lungo termine dei diversi trattamenti. Risultati: Sono stati inclusi in totale 467 pazienti (il 39% trattato solo con terapia medica, il 43% sottoposto a PEA, il 13% sottoposto a BPA e il 5% non ha ricevuto alcuna terapia). I pazienti trattati solo con terapia medica sono stati il gruppo più vecchio in termini di età, e confrontati rispetto ai pazienti sottoposti a PEA, mostravano minore capacità di esercizio, un profilo di rischio più elevato e minor miglioramento del profilo emodinamico, funzionale e della sopravvivenza. I pazienti sottoposti a BPA hanno avuto un miglioramento emodinamico inferiore rispetto ai pazienti sottoposti PEA, ma un miglioramento funzionale, dell'esercizio fisico e del profilo di rischio, e di sopravvivenza sovrapponibile ai pazienti sottoposti a PEA; la sopravvivenza è risultata migliore rispetto ai pazienti tsottoposti a sola terapia medica. Il gruppo di controllo storico di pazienti non trattati con alcuna terapia ha avuto la peggiore sopravvivenza. Conclusioni: Abbiamo confermato la superiorità della PEA rispetto a qualsiasi trattamento nei pazienti affetti da CTEPH, nei pazienti non operabili o con PH persistente/ricorrente dopo PEA, la BPA determina una prognosi migliore rispetto alla sola terapia medica.
Resumo:
This thesis is mainly about the search for exotic heavy particles -Intermediate Mass Magnetic Monopoles, Nuclearites and Q-balls with the SLIM experiment at the Chacaltaya High Altitude Laboratory (5230 m, Bolivia), establishing upper limits (90% CL) in the absence of candidates, which are among the best if not the only one for all three kind of particles. A preliminary study of the background induced by cosmic neutron in CR39 at the SLIM site, using Monte Carlo simulations. The measurement of the elemental abundance of the primary cosmic ray with the CAKE experiment on board of a stratospherical balloon; the charge distribution obtained spans in the range 5≤Z≤31. Both experiments were based on the use of plastic Nuclear Track Detectors, which records the passage of ionizing particles; by using some chemical reagents such passage can be make visible at optical microscopes.
Resumo:
Introduction The “eversion” technique for carotid endarterectomy (e-CEA), that involves the transection of the internal carotid artery at the carotid bulb and its eversion over the atherosclerotic plaque, has been associated with an increased risk of postoperative hypertension possibly due to a direct iatrogenic damage to the carotid sinus fibers. The aim of this study is to assess the long-term effect of the e-CEA on arterial baroreflex and peripheral chemoreflex function in humans. Methods A retrospective review was conducted on a prospectively compiled computerized database of 3128 CEAs performed on 2617 patients at our Center between January 2001 and March 2006. During this period, a total of 292 patients who had bilateral carotid stenosis ≥70% at the time of the first admission underwent staged bilateral CEAs. Of these, 93 patients had staged bilateral e-CEAs, 126 staged bilateral s- CEAs and 73 had different procedures on each carotid. CEAs were performed with either the eversion or the standard technique with routine Dacron patching in all cases. The study inclusion criteria were bilateral CEA with the same technique on both sides and an uneventful postoperative course after both procedures. We decided to enroll patients submitted to bilateral e-CEA to eliminate the background noise from contralateral carotid sinus fibers. Exclusion criteria were: age >70 years, diabetes mellitus, chronic pulmonary disease, symptomatic ischemic cardiac disease or medical therapy with b-blockers, cardiac arrhythmia, permanent neurologic deficits or an abnormal preoperative cerebral CT scan, carotid restenosis and previous neck or chest surgery or irradiation. Young and aged-matched healthy subjects were also recruited as controls. Patients were assessed by the 4 standard cardiovascular reflex tests, including Lying-to-standing, Orthostatic hypotension, Deep breathing, and Valsalva Maneuver. Indirect autonomic parameters were assessed with a non-invasive approach based on spectral analysis of EKG RR interval, systolic arterial pressure, and respiration variability, performed with an ad hoc software. From the analysis of these parameters the software provides the estimates of spontaneous baroreflex sensitivity (BRS). The ventilatory response to hypoxia was assessed in patients and controls by means of classic rebreathing tests. Results A total of 29 patients (16 males, age 62.4±8.0 years) were enrolled. Overall, 13 patients had undergone bilateral e-CEA (44.8%) and 16 bilateral s-CEA (55.2%) with a mean interval between the procedures of 62±56 days. No patient showed signs or symptoms of autonomic dysfunction, including labile hypertension, tachycardia, palpitations, headache, inappropriate diaphoresis, pallor or flushing. The results of standard cardiovascular autonomic tests showed no evidence of autonomic dysfunction in any of the enrolled patients. At spectral analysis, a residual baroreflex performance was shown in both patient groups, though reduced, as expected, compared to young controls. Notably, baroreflex function was better maintained in e-CEA, compared to standard CEA. (BRS at rest: young controls 19.93 ± 2.45 msec/mmHg; age-matched controls 7.75 ± 1.24; e-CEA 13.85 ± 5.14; s-CEA 4.93 ± 1.15; ANOVA P=0.001; BRS at stand: young controls 7.83 ± 0.66; age-matched controls 3.71 ± 0.35; e-CEA 7.04 ± 1.99; s-CEA 3.57 ± 1.20; ANOVA P=0.001). In all subjects ventilation (VÝ E) and oximetry data fitted a linear regression model with r values > 0.8. Oneway analysis of variance showed a significantly higher slope both for ΔVE/ΔSaO2 in controls compared with both patient groups which were not different from each other (-1.37 ± 0.33 compared with -0.33±0.08 and -0.29 ±0.13 l/min/%SaO2, p<0.05, Fig.). Similar results were observed for and ΔVE/ΔPetO2 (-0.20 ± 0.1 versus -0.01 ± 0.0 and -0.07 ± 0.02 l/min/mmHg, p<0.05). A regression model using treatment, age, baseline FiCO2 and minimum SaO2 achieved showed only treatment as a significant factor in explaining the variance in minute ventilation (R2= 25%). Conclusions Overall, we demonstrated that bilateral e-CEA does not imply a carotid sinus denervation. As a result of some expected degree of iatrogenic damage, such performance was lower than that of controls. Interestingly though, baroreflex performance appeared better maintained in e-CEA than in s-CEA. This may be related to the changes in the elastic properties of the carotid sinus vascular wall, as the patch is more rigid than the endarterectomized carotid wall that remains in the e-CEA. These data confirmed the safety of CEA irrespective of the surgical technique and have relevant clinical implication in the assessment of the frequent hemodynamic disturbances associated with carotid angioplasty stenting.
Resumo:
The vertical profile of aerosol in the planetary boundary layer of the Milan urban area is studied in terms of its development and chemical composition in a high-resolution modelling framework. The period of study spans a week in summer of 2007 (12-18 July), when continuous LIDAR measurements and a limited set of balloon profiles were collected in the frame of the ASI/QUITSAT project. LIDAR observations show a diurnal development of an aerosol plume that lifts early morning surface emissions to the top of the boundary layer, reaching maximum concentration around midday. Mountain breeze from Alps clean the bottom of the aerosol layer, typically leaving a residual layer at around 1500-2000 m which may survive for several days. During the last two days under analysis, a dust layer transported from Sahara reaches the upper layers of Milan area and affects the aerosol vertical distribution in the boundary layer. Simulation from the MM5/CHIMERE modelling system, carried out at 1 km horizontal resolution, qualitatively reproduced the general features of the Milan aerosol layer observed with LIDAR, including the rise and fall of the aersol plume, the residual layer in altitude and the Saharan dust event. The simulation highlighted the importance of nitrates and secondary organics in its composition. Several sensitivity tests showed that main driving factors leading to the dominance of nitrates in the plume are temperature and gas absorption process. A modelling study turn to the analysis of the vertical aerosol profiles distribution and knowledge of the characterization of the PM at a site near the city of Milan is performed using a model system composed by a meteorological model MM5 (V3-6), the mesoscale model from PSU/NCAR and a Chemical Transport Model (CTM) CHIMERE to simulate the vertical aerosol profile. LiDAR continuous observations and balloon profiles collected during two intensive campaigns in summer 2007 and in winter 2008 in the frame of the ASI/QUITSAT project have been used to perform comparisons in order to evaluate the ability of the aerosol chemistry transport model CHIMERE to simulate the aerosols dynamics and compositions in this area. The comparisons of model aerosols with measurements are carried out over a full time period between 12 July 2007 and 18 July 2007. The comparisons demonstrate the ability of the model to reproduce correctly the aerosol vertical distributions and their temporal variability. As detected by the LiDAR, the model during the period considered, predicts a diurnal development of a plume during the morning and a clearing during the afternoon, typically the plume reaches the top of the boundary layer around mid day, in this time CHIMERE produces highest concentrations in the upper levels as detected by LiDAR. The model, moreover can reproduce LiDAR observes enhancement aerosols concentrations above the boundary layer, attributing the phenomena to dust out intrusion. Another important information from the model analysis regard the composition , it predicts that a large part of the plume is composed by nitrate, in particular during 13 and 16 July 2007 , pointing to the model tendency to overestimates the nitrous component in the particular matter vertical structure . Sensitivity study carried out in this work show that there are a combination of different factor which determine the major nitrous composition of the “plume” observed and in particular humidity temperature and the absorption phenomena are the mainly candidate to explain the principal difference in composition simulated in the period object of this study , in particular , the CHIMERE model seems to be mostly sensitive to the absorption process.
Resumo:
Primary angioplasty has been shown to be more effective than fibrinolysis in terms of mortality and adverse outcomes. More recent data, however, suggests that timely reperfusion with fibrinolysis is comparable to primary angioplasty. The current study gathered data from the International Survey of Acute Coronary Syndromes in Transitional Countries registry. Among 7406 ST-elevation myocardial infarction patients presenting within 12 hours from symptom onset, 6315 underwent primary percutaneous coronary intervention and 1091 were treated with fibrinolysis. The primary outcome was 30-day mortality, while the secondary outcome was a composite of 30-day incidence of death, severe left ventricular dysfunction, stroke or reinfarction. Patients who underwent primary angioplasty tended to have a greater cardiovascular risk profile and were slightly older. On the other hand, patients treated with fibrinolysis received less anti-platelet medications yet were more often prescribed beta blockers in the acute phase. Among those who received fibrinolysis, 43% underwent coronary angiography while 32.3% were treated with a subsequent angioplasty. Total ischemic time was lower in patients undergoing fibrinolysis (185 minutes) than in those treated with primary angioplasty (258 minutes). Rates of primary and secondary combined endpoints were higher in patients receiving fibrinolysis compared to those receiving primary angioplasty (7.8% vs. 4.1%; p<0.0001; OR 1.97, 95% CI, 1.38-2.81; and 14.8% vs. 10.1%, p<0.0001; OR 1.43, 95% CI, 1.12-1.81). When considering only patients receiving reperfusion within 3 hours, regardless of reperfusion strategy, differences in mortality (6.3% vs. 4%, p=0.094, for fibrinolysis or primary angioplasty, respectively; OR 0.87, 95% CI, 0.35-2.16) and in the combined secondary endpoint were no longer observed (12.9% vs 10.8%, p=0.33; OR 0.98, 95% CI, 0.58-1.64), and female sex was no longer a significant predictor of adverse outcomes. When performed 3 hours from symptom onset, fibrinolysis is safe and feasible, in terms of mortality and adverse outcomes, compared to primary angioplasty.
Resumo:
Scopo Confrontare il trattamento transcatetere (TAVI) balloon-expandable con il trattamento chirurgico di sostituzione valvolare aortica (AVR) della stenosi valvolare aortica severa (SVAS) nella pratica clinica real world. Materiali e metodi Nel decennio 2010-2020, 1486 pazienti con SVAS isolata sono stati sottoposti a AVR (n=1049) o TAVI balloon-expandable (n=437) presso Hesperia Hospital Modena. Sono stati analizzati la Mortality nell’intera popolazione e gli episodi di ricovero cardiovascolare nei 5 anni precedenti e durante il follow-up nella popolazione residente in Emilia Romagna (n=1196) al momento della procedura (AVR n=879, TAVI balloon-expandable n=317). Risultati La popolazione TAVI è risultata mediamente più anziana di quella AVR (età media 82.2 vs. 72.7 anni) e maggiormente gravata da comorbidità. L’In-hospital mortality è stata del 1.4% nella AVR e 2.1% nella TAVI (pNS). La sopravvivenza a 5 anni è stata del 85.74% nella AVR e del 59.45% nella TAVI, con la TAVI come fattore predittivo di All-cause mortality (HR 1.44 95%CI 1.14-1.82). La riospedalizzazione per Heart Failure a 5 anni è stata del 20.6% per AVR e 51.3% per TAVI, con dialisi preoperatoria (HR 5.67 95%CI 3.06-10.49) come principale fattore predittivo. Il tasso di All Stroke a 5 anni è stato del 3.7% nella AVR e del 7.5% nella TAVI, con fibrillazione atriale preoperatoria come principale fattore predittivo (HR 1.91 95%CI 1.06-3.45). Il tasso di angioplastica coronarica percutanea (PCI) a 5 anni è stato del 3.1% sia nella AVR che nella TAVI, con previous PCI come principale fattore predittivo (HR 4.86 95%CI 2.57-9.21). L’impianto di pacemaker a 30 giorni è stato del 2.9% nella AVR e 3.4% nella TAVI (pNS). Conclusioni Nella pratica clinica real-world 2010-2020 di un centro cardiochirurgico a medio volume, la TAVI balloon-expandable ha mostrato una eccellente performance a 30 giorni in confronto con la AVR, che invece ha evidenziato una migliore performance durante follow-up.