3 resultados para Alumina. Porous membranes. Textile effluent. Filtration

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work of this thesis has been focused on the characterisation of inorganic membranes for the hydrogen purification from steam reforming gas. Composite membranes based on porous inorganic supports coated with palladium silver alloys and ceramic membranes have been analysed. A brief resume of theoretical laws governing transport of gases through dense and porous inorganic membranes and an overview on different methods to prepare inorganic membranes has been also reported. A description of the experimental apparatus used for the characterisation of gas permeability properties has been reported. The device used permits to evaluate transport properties in a wide range of temperatures (till 500°C) and pressures (till 15 bar). Data obtained from experimental campaigns reveal a good agreement with Sievert law for hydrogen transport through dense palladium based membranes while different transport mechanisms, such as Knudsen diffusion and Hagen-Poiseuille flow, have been observed for porous membranes and for palladium silver alloy ones with pinholes in the metal layer. Mixtures permeation experiments reveal also concentration polarisation phenomena and hydrogen permeability reduction due to carbon monoxide adsorption on metal surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chromatography represents one of the most important and widely used unit operation in the biotechnology industry. However this technique suffers from several limitations such as high pressure drop, slow mass transfer through the diffusive pores and strong dependence of the binding capacity on flow rate. In this work, affinity membranes with improved capacity have been considered as an alternative technology for the capturing step in antibody manufacturing. Several affinity membranes have been prepared starting from various membrane supports. Different affinity ligands have been utilized like Protein A, the natural ligand of choice for antibodies, as well as synthetic ligands that exhibit affinity for the Fc portion of antibodies. The membranes have been characterized in detail: binding and elution performance was evaluated in adsorption experiments using pure IgG solutions, while membrane selectivity was evaluated using complex solutions like a cell culture supernatant. The most promising affinity membranes were extensively tested in dynamic experiments. The effects of operating parameters like feed concentration and flow rate on separation performances like binding capacity, selectivity and process yield have been studied in detail in order to find the optimal conditions for binding and elution steps. The membranes have been used over several complete chromatographic cycles to evaluate the effects of ageing and of membrane regeneration on dynamic binding capacity. A novel mathematical model is proposed that can describe all the chromatographic steps involved in the membrane affinity chromatography process for protein purification. The mathematical description is based on the species continuity equation coupled with a proper binding kinetic equation, and suitable to describe adequately the dispersion phenomena occurring both in the micro-porous membranes as well as in the extra-column devices used in the system. The model considers specifically all the different chromatographic steps, namely adsorption, washing and elution. The few relevant fitting parameters of the model were derived from a calibration with the experimental affinity cycles performed with pure IgG solutions, then the model is used to describe experimental data obtained in chromatographic cycles carried out with complex feeds as the cell culture supernatant. Simulations reveal a good agreement with experimental data in all the chromatography steps, both in the case of pure IgG solutions and for the cell culture supernatant considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work of this thesis has been focused on the characterization of metallic membranes for the hydrogen purification from steam reforming process and also of perfluorosulphonic acid ionomeric (PFSI) membranes suitable as electrolytes in fuel cell applications. The experimental study of metallic membranes was divided in three sections: synthesis of palladium and silver palladium coatings on porous ceramic support via electroless deposition (ELD), solubility and diffusivity analysis of hydrogen in palladium based alloys (temperature range between 200 and 400 °C up to 12 bar of pressure) and permeation experiments of pure hydrogen and mixtures containing, besides hydrogen, also nitrogen and methane at high temperatures (up to 600 °C) and pressures (up to 10 bar). Sequential deposition of palladium and silver on to porous alumina tubes by ELD technique was carried out using two different procedures: a stirred batch and a continuous flux method. Pure palladium as well as Pd-Ag membranes were produced: the Pd-Ag membranes’ composition is calculated to be close to 77% Pd and 23% Ag by weight which was the target value that correspond to the best performance of the palladium-based alloys. One of the membranes produced showed an infinite selectivity through hydrogen and relatively high permeability value and is suitable for the potential use as a hydrogen separator. The hydrogen sorption in silver palladium alloys was carried out in a gravimetric system on films produced by ELD technique. In the temperature range inspected, up to 400°C, there is still a lack in literature. The experimental data were analyzed with rigorous equations allowing to calculate the enthalpy and entropy values of the Sieverts’ constant; the results were in very good agreement with the extrapolation made with literature data obtained a lower temperature (up to 150 °C). The information obtained in this study would be directly usable in the modeling of hydrogen permeation in Pd-based systems. Pure and mixed gas permeation tests were performed on Pd-based hydrogen selective membranes at operative conditions close to steam-reforming ones. Two membranes (one produced in this work and another produced by NGK Insulators Japan) showed a virtually infinite selectivity and good permeability. Mixture data revealed the existence of non negligible resistances to hydrogen transport in the gas phase. Even if the decrease of the driving force due to polarization concentration phenomena occurs, in principle, in all membrane-based separation systems endowed with high perm-selectivity, an extensive experimental analysis lack, at the moment, in the palladium-based membrane process in literature. Moreover a new procedure has been introduced for the proper comparison of the mass transport resistance in the gas phase and in the membrane. Another object of study was the water vapor sorption and permeation in PFSI membranes with short and long side chains was also studied; moreover the permeation of gases (i.e. He, N2 and O2) in dry and humid conditions was considered. The water vapor sorption showed strong interactions between the hydrophilic groups and the water as revealed from the hysteresis in the sorption-desorption isotherms and thermo gravimetric analysis. The data obtained were used in the modeling of water vapor permeation, that was described as diffusion-reaction of water molecules, and in the humid gases permeation experiments. In the dry gas experiments the permeability and diffusivity was found to increase with temperature and with the equivalent weight (EW) of the membrane. A linear correlation was drawn between the dry gas permeability and the opposite of the equivalent weight of PFSI membranes, based on which the permeability of pure PTFE is retrieved in the limit of high EW. In the other hand O2 ,N2 and He permeability values was found to increase significantly, and in a similar fashion, with water activity. A model that considers the PFSI membrane as a composite matrix with a hydrophilic and a hydrophobic phase was considered allowing to estimate the variation of gas permeability with relative humidity on the basis of the permeability in the dry PFSI membrane and in pure liquid water.