3 resultados para 854
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
In the present study we are using multi variate analysis techniques to discriminate signal from background in the fully hadronic decay channel of ttbar events. We give a brief introduction to the role of the Top quark in the standard model and a general description of the CMS Experiment at LHC. We have used the CMS experiment computing and software infrastructure to generate and prepare the data samples used in this analysis. We tested the performance of three different classifiers applied to our data samples and used the selection obtained with the Multi Layer Perceptron classifier to give an estimation of the statistical and systematical uncertainty on the cross section measurement.
Resumo:
The research activity carried out during the PhD course in Electrical Engineering belongs to the branch of electric and electronic measurements. The main subject of the present thesis is a distributed measurement system to be installed in Medium Voltage power networks, as well as the method developed to analyze data acquired by the measurement system itself and to monitor power quality. In chapter 2 the increasing interest towards power quality in electrical systems is illustrated, by reporting the international research activity inherent to the problem and the relevant standards and guidelines emitted. The aspect of the quality of voltage provided by utilities and influenced by customers in the various points of a network came out only in recent years, in particular as a consequence of the energy market liberalization. Usually, the concept of quality of the delivered energy has been associated mostly to its continuity. Hence the reliability was the main characteristic to be ensured for power systems. Nowadays, the number and duration of interruptions are the “quality indicators” commonly perceived by most customers; for this reason, a short section is dedicated also to network reliability and its regulation. In this contest it should be noted that although the measurement system developed during the research activity belongs to the field of power quality evaluation systems, the information registered in real time by its remote stations can be used to improve the system reliability too. Given the vast scenario of power quality degrading phenomena that usually can occur in distribution networks, the study has been focused on electromagnetic transients affecting line voltages. The outcome of such a study has been the design and realization of a distributed measurement system which continuously monitor the phase signals in different points of a network, detect the occurrence of transients superposed to the fundamental steady state component and register the time of occurrence of such events. The data set is finally used to locate the source of the transient disturbance propagating along the network lines. Most of the oscillatory transients affecting line voltages are due to faults occurring in any point of the distribution system and have to be seen before protection equipment intervention. An important conclusion is that the method can improve the monitored network reliability, since the knowledge of the location of a fault allows the energy manager to reduce as much as possible both the area of the network to be disconnected for protection purposes and the time spent by technical staff to recover the abnormal condition and/or the damage. The part of the thesis presenting the results of such a study and activity is structured as follows: chapter 3 deals with the propagation of electromagnetic transients in power systems by defining characteristics and causes of the phenomena and briefly reporting the theory and approaches used to study transients propagation. Then the state of the art concerning methods to detect and locate faults in distribution networks is presented. Finally the attention is paid on the particular technique adopted for the same purpose during the thesis, and the methods developed on the basis of such approach. Chapter 4 reports the configuration of the distribution networks on which the fault location method has been applied by means of simulations as well as the results obtained case by case. In this way the performance featured by the location procedure firstly in ideal then in realistic operating conditions are tested. In chapter 5 the measurement system designed to implement the transients detection and fault location method is presented. The hardware belonging to the measurement chain of every acquisition channel in remote stations is described. Then, the global measurement system is characterized by considering the non ideal aspects of each device that can concur to the final combined uncertainty on the estimated position of the fault in the network under test. Finally, such parameter is computed according to the Guide to the Expression of Uncertainty in Measurements, by means of a numeric procedure. In the last chapter a device is described that has been designed and realized during the PhD activity aiming at substituting the commercial capacitive voltage divider belonging to the conditioning block of the measurement chain. Such a study has been carried out aiming at providing an alternative to the used transducer that could feature equivalent performance and lower cost. In this way, the economical impact of the investment associated to the whole measurement system would be significantly reduced, making the method application much more feasible.
Resumo:
La città medievale di Leopoli-Cencelle (fondata da Papa Leone IV nell‘854 d.C. non lontano da Civitavecchia) è stata oggetto di studio e di periodiche campagne di scavo a partire dal 1994. Le stratigrafie investigate con metodi tradizionali, hanno portato alla luce le numerose trasformazioni che la città ha subìto nel corso della sua esistenza in vita. Case, torri, botteghe e strati di vissuto, sono stati interpretati sin dall’inizio dello scavo basandosi sulla documentazione tradizionale e bi-dimensionale, legata al dato cartaceo e al disegno. Il presente lavoro intende re-interpretare i dati di scavo con l’ausilio delle tecnologie digitali. Per il progetto sono stati utilizzati un laser scanner, tecniche di Computer Vision e modellazione 3D. I tre metodi sono stati combinati in modo da poter visualizzare tridimensionalmente gli edifici abitativi scavati, con la possibilità di sovrapporre semplici modelli 3D che permettano di formulare ipotesi differenti sulla forma e sull’uso degli spazi. Modellare spazio e tempo offrendo varie possibilità di scelta, permette di combinare i dati reali tridimensionali, acquisiti con un laser scanner, con semplici modelli filologici in 3D e offre l’opportunità di valutare diverse possibili interpretazioni delle caratteristiche dell’edificio in base agli spazi, ai materiali, alle tecniche costruttive. Lo scopo del progetto è andare oltre la Realtà Virtuale, con la possibilità di analizzare i resti e di re-interpretare la funzione di un edificio, sia in fase di scavo che a scavo concluso. Dal punto di vista della ricerca, la possibilità di visualizzare le ipotesi sul campo favorisce una comprensione più profonda del contesto archeologico. Un secondo obiettivo è la comunicazione a un pubblico di “non-archeologi”. Si vuole offrire a normali visitatori la possibilità di comprendere e sperimentare il processo interpretativo, fornendo loro qualcosa in più rispetto a una sola ipotesi definitiva.