23 resultados para Pyro-electric detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Zero Degree Calorimeter (ZDC) of the ATLAS experiment at CERN is placed in the TAN of the LHC collider, covering the pseudorapidity region higher than 8.3. It is composed by 2 calorimeters, each one longitudinally segmented in 4 modules, located at 140 m from the IP exactly on the beam axis. The ZDC can detect neutral particles during pp collisions and it is a tool for diffractive physics. Here we present results on the forward photon energy distribution obtained using p-p collision data at sqrt{s} = 7 TeV. First the pi0 reconstruction will be used for the detector calibration with photons, then we will show results on the forward photon energy distribution in p-p collisions and the same distribution, but obtained using MC generators. Finally a comparison between data and MC will be shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis three measurements of top-antitop differential cross section at an energy in the center of mass of 7 TeV will be shown, as a function of the transverse momentum, the mass and the rapidity of the top-antitop system. The analysis has been carried over a data sample of about 5/fb recorded with the ATLAS detector. The events have been selected with a cut based approach in the "one lepton plus jets" channel, where the lepton can be either an electron or a muon. The most relevant backgrounds (multi-jet QCD and W+jets) have been extracted using data driven methods; the others (Z+ jets, diboson and single top) have been simulated with Monte Carlo techniques. The final, background-subtracted, distributions have been corrected, using unfolding methods, for the detector and selection effects. At the end, the results have been compared with the theoretical predictions. The measurements are dominated by the systematic uncertainties and show no relevant deviation from the Standard Model predictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multidetector row computed tomography over the last decade is commonly used in veterinary medicine. This new technology has an increased spatial and temporal resolution, could evaluate wider scanning range in shorter scanning time, providing an advanced imaging modality. Computed tomography angiographic studies are commonly used in veterinary medicine in order to evaluate vascular structures of the abdomen and the thorax. Pulmonary pathology in feline patients is a very common condition and usually is further evaluating with computed tomography. Up to date few references of the normal computed tomographic aspects of the feline thorax are reported. In this study a computed tomographic pulmonary angiography (CTPA) protocol is reported in normal cats and is compared with the up to date anatomical references. A CTPA protocol using a 64 MDCT in our study achieved high resolution images of the pulmonary arteries, pulmonary veins and bronchial lumen till the level of minor segmental branches. Feline pulmonary bronchial parenchyma demonstrates an architecture of mixed type with a monopedial model observed in the most anatomical parts and the dichotomic aspect is seen at the accessory lobe. The arterial and venous architecture is similar to the bronchial. Statistical analysis demonstrates the linear correlation of tracheal diameter to the felines weight. Vascular variations were noticed. The pulmonary venous system enters into the left atrium through three ostia (left cranial ostia: consisted of the anastomosis of the cranial and caudal portion of the left cranial pulmonary vein; right ostia: consisted of the anastomosis of the right cranial and middle pulmonary vein; and the caudal ostia: consisted of the anastomosis of the right and left caudal pulmonary vein). In conclusion CTPA is applicable in feline patients and provides an excellent imaging of the pulmonary arterial, venous and bronchial system till the level of minor segmental branches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The international growing concern for the human exposure to magnetic fields generated by electric power lines has unavoidably led to imposing legal limits. Respecting these limits, implies being able to calculate easily and accurately the generated magnetic field also in complex configurations. Twisting of phase conductors is such a case. The consolidated exact and approximated theory regarding a single-circuit twisted three-phase power cable line has been reported along with the proposal of an innovative simplified formula obtained by means of an heuristic procedure. This formula, although being dramatically simpler, is proven to be a good approximation of the analytical formula and at the same time much more accurate than the approximated formula found in literature. The double-circuit twisted three-phase power cable line case has been studied following different approaches of increasing complexity and accuracy. In this framework, the effectiveness of the above-mentioned innovative formula is also examined. The experimental verification of the correctness of the twisted double-circuit theoretical analysis has permitted its extension to multiple-circuit twisted three-phase power cable lines. In addition, appropriate 2D and, in particularly, 3D numerical codes for simulating real existing overhead power lines for the calculation of the magnetic field in their vicinity have been created. Finally, an innovative ‘smart’ measurement and evaluation system of the magnetic field is being proposed, described and validated, which deals with the experimentally-based evaluation of the total magnetic field B generated by multiple sources in complex three-dimensional arrangements, carried out on the basis of the measurement of the three Cartesian field components and their correlation with the field currents via multilinear regression techniques. The ultimate goal is verifying that magnetic induction intensity is within the prescribed limits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thesis work concerns X-ray spectrometry for both medical and space applications and is divided into two sections. The first section addresses an X-ray spectrometric system designed to study radiological beams and is devoted to the optimization of diagnostic procedures in medicine. A parametric semi-empirical model capable of efficiently reconstructing diagnostic X-ray spectra in 'middle power' computers was developed and tested. In addition, different silicon diode detectors were tested as real-time detectors in order to provide a real-time evaluation of the spectrum during diagnostic procedures. This project contributes to the field by presenting an improved simulation of a realistic X-ray beam emerging from a common X-ray tube with a complete and detailed spectrum that lends itself to further studies of added filtration, thus providing an optimized beam for different diagnostic applications in medicine. The second section describes the preliminary tests that have been carried out on the first version of an Application Specific Integrated Circuit (ASIC), integrated with large area position-sensitive Silicon Drift Detector (SDD) to be used on board future space missions. This technology has been developed for the ESA project: LOFT (Large Observatory for X-ray Timing), a new medium-class space mission that the European Space Agency has been assessing since February of 2011. The LOFT project was proposed as part of the Cosmic Vision Program (2015-2025).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present dissertation aims to explore, theoretically and experimentally, the problems and the potential advantages of different types of power converters for “Smart Grid” applications, with particular emphasis on multi-level architectures, which are attracting a rising interest even for industrial requests. The models of the main multilevel architectures (Diode-Clamped and Cascaded) are shown. The best suited modulation strategies to function as a network interface are identified. In particular, the close correlation between PWM (Pulse Width Modulation) approach and SVM (Space Vector Modulation) approach is highlighted. An innovative multilevel topology called MMC (Modular Multilevel Converter) is investigated, and the single-phase, three-phase and "back to back" configurations are analyzed. Specific control techniques that can manage, in an appropriate way, the charge level of the numerous capacitors and handle the power flow in a flexible way are defined and experimentally validated. Another converter that is attracting interest in “Power Conditioning Systems” field is the “Matrix Converter”. Even in this architecture, the output voltage is multilevel. It offers an high quality input current, a bidirectional power flow and has the possibility to control the input power factor (i.e. possibility to participate to active and reactive power regulations). The implemented control system, that allows fast data acquisition for diagnostic purposes, is described and experimentally verified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first part of this thesis has focused on the construction of a twelve-phase asynchronous machine for More Electric Aircraft (MEA) applications. In fact, the aerospace world has found in electrification the way to improve the efficiency, reliability and maintainability of an aircraft. This idea leads to the aircraft a new management and distribution of electrical services. In this way is possible to remove or to reduce the hydraulic, mechanical and pneumatic systems inside the aircraft. The second part of this dissertation is dedicated on the enhancement of the control range of matrix converters (MCs) operating with non-unity input power factor and, at the same time, on the reduction of the switching power losses. The analysis leads to the determination in closed form of a modulation strategy that features a control range, in terms of output voltage and input power factor, that is greater than that of the traditional strategies under the same operating conditions, and a reduction in the switching power losses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In food industry, quality assurance requires low cost methods for the rapid assessment of the parameters that affect product stability. Foodstuffs are complex in their structure, mainly composed by gaseous, liquid and solid phases which often coexist in the same product. Special attention is given to water, concerned as natural component of the major food product or as added ingredient of a production process. Particularly water is structurally present in the matrix and not completely available. In this way, water can be present in foodstuff in many different states: as water of crystallization, bound to protein or starch molecules, entrapped in biopolymer networks or adsorbed on solid surfaces of porous food particles. The traditional technique for the assessment of food quality give reliable information but are destructive, time consuming and unsuitable for on line application. The techniques proposed answer to the limited disposition of time and could be able to characterize the main compositional parameters. Dielectric interaction response is mainly related to water and could be useful not only to provide information on the total content but also on the degree of mobility of this ubiquitous molecule in different complex food matrix. In this way the proposal of this thesis is to answer at this need. Dielectric and electric tool can be used for the scope and led us to describe the complex food matrix and predict food characteristic. The thesis is structured in three main part, in the first one some theoretical tools are recalled to well assess the food parameter involved in the quality definition and the techniques able to reply at the problem emerged. The second part explains the research conducted and the experimental plans are illustrated in detail. Finally the last section is left for rapid method easily implementable in an industrial process.