2 resultados para particle, air distribution

em Academic Archive On-line (Stockholm University


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aerosol particles are likely important contributors to our future climate. Further, during recent years, effects on human health arising from emissions of particulate material have gained increasing attention. In order to quantify the effect of aerosols on both climate and human health we need to better quantify the interplay between sources and sinks of aerosol particle number and mass on large spatial scales. So far long-term, regional observations of aerosol properties have been scarce, but argued necessary in order to bring the knowledge of regional and global distribution of aerosols further. In this context, regional studies of aerosol properties and aerosol dynamics are truly important areas of investigation. This thesis is devoted to investigations of aerosol number size distribution observations performed through the course of one year encompassing observational data from five stations covering an area from southern parts of Sweden up to northern parts of Finland. This thesis tries to give a description of aerosol size distribution dynamics from both a quantitative and qualitative point of view. The thesis focuses on properties and changes in aerosol size distribution as a function of location, season, source area, transport pathways and links to various meteorological conditions. The investigations performed in this thesis show that although the basic behaviour of the aerosol number size distribution in terms of seasonal and diurnal characteristics is similar at all stations in the measurement network, the aerosol over the Nordic countries is characterised by a typically sharp gradient in aerosol number and mass. This gradient is argued to derive from geographical locations of the stations in relation to the dominant sources and transport pathways. It is clear that the source area significantly determine the aerosol size distribution properties, but it is obvious that transport condition in terms of frequency of precipitation and cloudiness in some cases even more strongly control the evolution of the number size distribution. Aerosol dynamic processes under clear sky transport are however likewise argued to be highly important. Southerly transport of marine air and northerly transport of air from continental sources is studied in detail under clear sky conditions by performing a pseudo-Lagrangian box model evaluation of the two type cases. Results from both modelling and observations suggest that nucleation events contribute to integral number increase during southerly transport of comparably clean marine air, while number depletion dominates the evolution of the size distribution during northerly transport. This difference is largely explained by different concentration of pre-existing aerosol surface associated with the two type cases. Mass is found to be accumulated in many of the individual transport cases studied. This mass increase was argued to be controlled by emission of organic compounds from the boreal forest. This puts the boreal forest in a central position for estimates of aerosol forcing on a regional scale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the work underlying this thesis solid-phase microextraction (SPME) was evaluated as a passive sampling technique for organophosphate triesters in indoor air. These compounds are used on a large scale as flame-retarding and plastizicing additives in a variety of materials and products, and have proven to be common pollutants in indoor air. The main objective of this work was to develop an accurate method for measuring the volatile fraction. Such a method can be used in combination with active sampling to obtain information regarding the vapour/particulate distribution in different indoor environments. SPME was investigated under both equilibrium and non-equilibrium conditions and parameters associated with these different conditions were estimated. In Paper I, time-weighted average (TWA) SPME under dynamic conditions was investigated in order to obtain a fast air sampling method for organophosphate triesters. Among the investigated SPME coatings, the absorptive PDMS polymer had the highest affinity for the organophosphate triesters and was consequently used in all further work. Since the sampling rate is dependent on the agitation conditions, the linear airflow rates had to be carefully considered. Sampling periods as short as 1 hour were shown to be sufficient for measurements in the ng-μg m-3 range when using a PDMS 100-μm fibre and a linear flow rate above 7 cm s-1 over the fibre. SPME under equilibrium conditions is rather time-consuming, even under dynamic conditions, for slowly partitioning compounds such as organophosphate triesters. Nevertheless, this method has some significant advantages. For instance, the limit of detection is much lower compared to 1 h TWA sampling. Furthermore, the sampling time can be ignored as long as equilibrium has been attained. In Paper II, SPME under equilibrium conditions was investigated and evaluated for organophosphate triester vapours. Since temperature and humidity are closely associated with the distribution constant a simple study of the effect of these parameters was performed. The obtained distribution constants were used to determine the air levels in a common indoor environment. SPME and parallel active sampling on filters yielded similar results, indicating that the detected compounds were almost entirely associated with the vapour phase To apply dynamic SPME method in the field a sampler device, which enables controlled linear airflow rates to be applied, was constructed and evaluated (Paper III). This device was developed for application of SPME and active sampling in parallel. A GC/PICI-MS/MS method was developed and used in combination with active sampling of organophosphate triesters in indoor air (Paper IV). The combination of MS/MS and the soft ionization achieved with methanol as reagent gas yielded high selectivity and detection limits comparable to those provided by GC with nitrogen-phosphorus detection (NPD). The method limit of detection, when sampling 1.5 m3 of air, was in the range 0.1-1.4 ng m-3. In Paper V, the developed MS method was used in combination with SPME for indoor air measurements. The levels detected in the investigated indoor environments range from a few ng to μg m-3. Tris(2-chloropropyl) phosphate was detected at a concentration as high as 7 μg m-3 in a newly rebuilt lecture room.