6 resultados para visual sensitivity

em Universidade Federal do Pará


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55%) performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81%). Three gold miners and 1 riverine (4/19 subjects, 21%) performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50%), comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O potencial provocado visual (VEP) é uma resposta cortical registrável na superfície do couro cabeludo, que reflete a atividade dos neurônios de V1. É classificado, a partir da freqüência temporal de estimulação, em transiente ou de estado estacionário. Outras propriedades do estímulo parecem provocar uma atividade seletiva dos diversos grupos de neurônios existentes em V1. Desse modo, o VEP vem sendo usado para estudar a visão humana acromática e cromática. Diversos trabalhos usaram o VEP para estimar a sensibilidade ao contraste de luminância no domínio das freqüências espaciais. Mais recentemente, há estudos que empregaram o VEP para medir os limiares de discriminação de cores. O VEP transiente pode complementar as medidas psicofísicas de sensibilidade ao contraste espacial de luminância e de discriminação cromática, e constitui um método não invasivo para estudar a visão de indivíduos com dificuldades de realizar testes psicofísicos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to compare contrast sensitivity estimated from transient visual evoked potentials (VEPs) elicited by achromatic pattern-reversal and pattern-onset/offset modes. The stimuli were 2-cpd, achromatic horizontal gratings presented either as a 1 Hz pattern reversal or a 300 ms onset/700 ms offset stimulus. Contrast thresholds were estimated by linear regression to amplitudes of VEP components vs. the logarithm of the stimulus contrasts, and these regressions were extrapolated to the zero amplitude level. Contrast sensitivity was defined as the inverse of contrast threshold. For pattern reversal, the relation between the P100 amplitude and log of the stimulus contrast was best described by two separate linear regressions. For the N135 component, a single straight line was sufficient. In the case of pattern onset/offset for both the C1 and C2 components, single straight lines described their amplitude vs. log contrast relations in the medium-to-low contrast range. Some saturation was observed for C2 components. The contrast sensitivity estimated from the low-contrast limb of the P100, from the N135, and from the C2 were all similar but higher than those obtained from the high-contrast limb of the P100 and C1 data, which were also similar to each other. With 2 cpd stimuli, a mechanism possibly driven by the M pathway appeared to contribute to the P100 component at medium-to-low contrasts and to the N135 and C2 components at all contrast levels, whereas another mechanism, possibly driven by the P and M pathways, appeared to contribute to the P100 component at high contrast and C1 component at all contrast levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Os solventes orgânicos são substâncias neurotóxicas que podem causar efeitos danosos sobre as funções visuais. É comum a exposição ocupacional a esses tipos de substâncias, pois elas apresentam grande aplicabilidade em inúmeras atividades. Os efeitos podem ser quantificados por testes psicofísicos. Os testes mais usados nesse tipo de avaliação são de ordenamento de matizes, como o Teste D15 Dessaturado de Lanthony e o Teste dos 100 Matizes de Farnsworth-Munsell, e avaliação de sensibilidade ao contraste espacial de luminância, como MCT 8000 Vistech, VCTS 6500 Vistech e FACT 101. Em geral esses testes descrevem perda de discriminação de cores, afetando tanto o eixo azul-amarelo quanto o eixo verde-vermelho, e diminuição da sensibilidade ao contraste de luminância principalmente para as frequências espaciais mais baixas. Existe correlação positiva entre os resultados da avaliação psicofísica e vários marcadores biológicos e ambientais, mas essa correlação depende do marcador e do tipo de solvente ao qual os indivíduos são expostos. Fatores como alcoolismo crônico e tabagismo inveterado podem interferir no processo de correlacionar esses resultados.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The luminance contrast sensitivity function has been investigated using behavioral and electrophysiological methods in many vertebrate species. Some features are conserved across species as a shape of the function, but other features, such as the contrast sensitivity peak value, spatial frequency contrast sensitivity peak, and visual acuity have changed. Here, we review contrast sensitivity across different classes of vertebrates, with an emphasis on the frequency contrast sensitivity peak and visual acuity. We also correlate the data obtained from the literature to test the power of the association between visual acuity and the spatial frequency of the contrast sensitivity function peak.