3 resultados para reactor components
em Universidade Federal do Pará
Resumo:
The purpose of this study was to compare contrast sensitivity estimated from transient visual evoked potentials (VEPs) elicited by achromatic pattern-reversal and pattern-onset/offset modes. The stimuli were 2-cpd, achromatic horizontal gratings presented either as a 1 Hz pattern reversal or a 300 ms onset/700 ms offset stimulus. Contrast thresholds were estimated by linear regression to amplitudes of VEP components vs. the logarithm of the stimulus contrasts, and these regressions were extrapolated to the zero amplitude level. Contrast sensitivity was defined as the inverse of contrast threshold. For pattern reversal, the relation between the P100 amplitude and log of the stimulus contrast was best described by two separate linear regressions. For the N135 component, a single straight line was sufficient. In the case of pattern onset/offset for both the C1 and C2 components, single straight lines described their amplitude vs. log contrast relations in the medium-to-low contrast range. Some saturation was observed for C2 components. The contrast sensitivity estimated from the low-contrast limb of the P100, from the N135, and from the C2 were all similar but higher than those obtained from the high-contrast limb of the P100 and C1 data, which were also similar to each other. With 2 cpd stimuli, a mechanism possibly driven by the M pathway appeared to contribute to the P100 component at medium-to-low contrasts and to the N135 and C2 components at all contrast levels, whereas another mechanism, possibly driven by the P and M pathways, appeared to contribute to the P100 component at high contrast and C1 component at all contrast levels.
Resumo:
The aim of this work was to isolate and investigate subcortical and cortical lateral interactions involved in flicker perception. We quantified the perceived flicker strength (PFS) in the center of a test stimulus which was simultaneously modulated with a surround stimulus (50% Michelson contrast in both stimuli). Subjects were requested to adjust the modulation depth of a separate matching stimulus that was physically identical to the center of the test stimulus but without the surround. Using LCD goggles, synchronized to the frame rate of a CRT screen, the center and surround could be presented monoptically or dichoptically. In the monoptic condition, center-surround interactions can have both subcortical and cortical origins. In the dichoptic condition, center-surround interactions cannot occur in the retina and the LGN, therefore isolating a cortical mechanism. Results revealed both a strong monoptic (subcortical plus cortical) lateral interaction and a weaker dichoptic (cortical) lateral interaction. Subtraction of the dichoptic from the monoptic data revealed a subcortical mechanism of the lateral interaction. While the modulation of the cortical PFS component showed a low-pass temporal-frequency tuning, the modulation of the subcortical PFS component was maximal at 6 Hz. These findings are consistent with two separate temporal channels influencing the monoptic PFS, each with distinct lateral interactions strength and frequency tuning characteristics. We conclude that both subcortical and cortical lateral interactions modulate flicker perception.
Resumo:
Nos sistemas elétricos de potência, os reatores em derivação são os equipamentos responsáveis pela redução ou mesmo anulação dos efeitos capacitivos indesejáveis na operação das linhas. Percebe-se, então, a importância desses equipamentos e a necessidade de mantê-los em perfeito funcionamento, pois uma falha grave gera um elevado custo de manutenção corretiva, queda nos indicadores de desempenho, além de multas por parte da agência reguladora - Agência Nacional de Energia Elétrica - ANEEL. O ciclo de vida de um reator em derivação envolve oito etapas - Planejamento, Especificação, Aquisição, Fabricação, Instalação, Comissionamento, Exploração e Desclassificação. Neste trabalho serão abordados apenas aspectos relativos à gestão da fase de exploração, que contempla o conjunto de processos de operação e manutenção de acordo com as perspectivas da empresa onde este estudo foi realizado. O processo de envelhecimento do reator pode ocorrer de diversas maneiras, no entanto o tempo de vida útil de um reator é condicionado essencialmente por dois fatores: a velocidade de envelhecimento e perda de robustez dos seus materiais e componentes e, as condições de funcionamento a que está sujeito ao longo do tempo. Para evitar danos aos reatores, as empresas de energia elétrica têm adotado procedimentos de manutenção preventivo e preditivo, que quando baseados em diagnósticos de diferentes métodos de avaliação tem um impacto fundamental na vida útil e confiabilidade dos reatores. Sendo a condição de degradação de um reator um processo contínuo no tempo, este pode ser classificado em cinco estágios: Novo, Normal, Anormal, Defeituoso e Falhado. Um índice de condição (IC) pode ser atribuído a cada um destes estágios de degradação, de acordo com os resultados de um conjunto de testes de diagnósticos para análise do estado de operação do reator e estimação da sua posição atual em relação ao seu ciclo de vida. Esta dissertação trata do desenvolvimento de uma metodologia para sistematizar a análise com a combinação de catorze diferentes métodos de diagnósticos e mapear os resultados em um modelo de condição que oriente o ciclo de vida do reator. A metodologia foi aplicada em dez reatores de 500 kV em duas subestações da Eletrobras-Eletronorte no Sistema de Transmissão do Pará, empresa na qual foi realizado este estudo.