3 resultados para Powder formulations

em Universidade Federal do Pará


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spent anodes, denominated butts in the aluminum industry, are recycled as part of the raw material used to produce new anodes. The fragmentation of the butt generates some sodium-rich powder, which is captured and included in the recycled material. This paper evaluates the influence of sodium content on anode reactivity. Six formulations with 0 to 25% butt powder were used. An average increase of 48 ppm of sodium from one to another formulation caused average increments of 3.38 and 2.72% for air and CO2 reactivity, respectively. The quality-related figures varied from 1.34 to 1.12 for CO2 and from 1.10 to 0.62 for air, showing quality loss in higher sodium content and higher impact on air reactivity. The Fischer formula predicted a carbon specific consumption of - 48.47 kg.t-1 Al for baked carbon anodes with 127 ppm to 367 ppm of sodium content, showing that the sodium can cause relevant carbon losses and increase costs of the aluminum production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: The present work uses multivariate statistical analysis as a form of establishing the main sources of error in the Quantitative Phase Analysis (QPA) using the Rietveld method. The quantitative determination of crystalline phases using x ray powder diffraction is a complex measurement process whose results are influenced by several factors. Ternary mixtures of Al2O3, MgO and NiO were prepared under controlled conditions and the diffractions were obtained using the Bragg-Brentano geometric arrangement. It was possible to establish four sources of critical variations: the experimental absorption and the scale factor of NiO, which is the phase with the greatest linear absorption coefficient of the ternary mixture; the instrumental characteristics represented by mechanical errors of the goniometer and sample displacement; the other two phases (Al2O3 and MgO); and the temperature and relative humidity of the air in the laboratory. The error sources excessively impair the QPA with the Rietveld method. Therefore it becomes necessary to control them during the measurement procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Descreve-se um eletrodo de carbono modificado com fosfato de cobre (II) imobilizado em uma resina de poliéster (Cu3(PO4)2-Poly) para a determinação de rutina em amostras farmacêuticas por voltametria de onda quadrada. O eletrodo modificado permite a determinação de rutina em potencial (0.20 V vs Ag / AgCl (3,0 mol L-1 KCl)) menor que o observado em um eletrodo não modificado. Verificou-se que a corrente de pico foi linear com a concentração de rutina na faixa de 9,9 × 10-8 a 2,5 × 10-6 mol L-1, com um limite de detecção de 1,2 × 10-8 mol L-1. A resposta do eletrodo foi estável, sem variação significativa dentro de várias horas de operação contínua. A morfologia da superfície do eletrodo modificado foi caracterizada por microscopia eletrônica de varredura (MEV) e pelo sistema de energia dispersiva de raios-X (EDX). Os resultados obtidos foram precisos e exatos. Ademais, estes resultados estão de acordo com aqueles obtidos pelo método cromatográfico a um nível de confiança de 95%.