4 resultados para Performance comparison

em Universidade Federal do Pará


Relevância:

70.00% 70.00%

Publicador:

Resumo:

ABSTRACT: This paper presents a performance comparison between known propagation Models through least squares tuning algorithm for 5.8 GHz frequency band. The studied environment is based on the 12 cities located in Amazon Region. After adjustments and simulations, SUI Model showed the smaller RMS error and standard deviation when compared with COST231-Hata and ECC-33 models.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Neste trabalho é proposta uma nova metodologia de projeto de estabilizadores de sistemas de potência baseada em teoria de sistemas de ordem fracionária (ESP-OF). A estratégia é baseada em uma generalização do projeto de compensadores do tipo rede avançoatraso (lead-lag) para o domínio de funções de transferência de ordem fracionária. Uma nova variável de projeto, a qual define a ordem da dinâmica fracionária do controlador, é sintonizada para se obter um compromisso entre um bom desempenho no amortecimento do modo eletromecânico dominante e uma robustez ampliada do ESP-OF. O desempenho do ESP-OF foi avaliado experimentalmente, em um sistema de potência em escala reduzida, localizado no Laboratório de Sistemas de Potência da Universidade Federal do Pará. A referida planta de teste apresenta uma estrutura típica do tipo gerador síncrono conectado a um barramento infinito e exibe um modo dominante de oscilação eletromecânica, de amortecimento extremamente reduzido, cujo valor da frequência natural é em torno de 1,2 Hz. O ESP-OF foi então projetado para ampliar o amortecimento relativo desse modo alvo, para toda a faixa de operação admissível. Para fins de implementação prática, primeiramente foram realizados testes experimentais para a identificação de um modelo nominal da planta, sob a forma de uma função de transferência pulsada, para uso na fase de projeto. O modelo obtido experimentalmente foi então validado e posteriormente utilizado tanto para o projeto do ESP-OF quanto para o projeto de um ESP convencional (utilizado para fins de comparação de desempenho). As leis de controle amortecedor do ESP-OF foram calculadas, convertidas para a forma de equações a diferenças e, subsequentemente, embarcadas em sistema digital baseado em microcontrolador DSPIC. Diversos testes de resposta ao impulso foram realizadas sob diferentes condições operacionais. As respectivas respostas dinâmicas dos sinais de saída da planta (desvio de potencia ativa) e do esforço de controle foram registradas para fins de análise. Os resultados experimentais mostraram que o ESP fracionário apresentou um desemprenho dinâmico e robustez similar em comparação com o desempenho obtido por um ESP convencional, para toda a faixa de operação investigada.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A "second generation" matching-to-sample procedure that minimizes past sources of artifacts involves (1) successive discrimination between sample stimuli, (2) stimulus displays ranging from four to 16 comparisons, (3) variable stimulus locations to avoid unwanted stimulus-location control, and (4) high accuracy levels (e.g., 90% correct on a 16-choice task in which chance accuracy is 6%). Examples of behavioral engineering with experienced capuchin monkeys included four-choice matching problems with video images of monkeys with substantially above-chance matching in a single session and 90% matching within six sessions. Exclusion performance was demonstrated by interspersing non-identical sample-comparison pairs within a baseline of a nine-comparison identity-matching-to-sample procedure with pictures as stimuli. The test for exclusion presented the newly "mapped" stimulus in a situation in which exclusion was not possible. Degradation of matching between physically non-identical forms occurred while baseline identity accuracy was sustained at high levels, thus confirming that Cebus cf. apella is capable of exclusion. Additionally, exclusion performance when baseline matching relations involved non-identical stimuli was shown.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m2 mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.