2 resultados para Load analyser

em Universidade Federal do Pará


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Host genetic factors play an important role in mediating resistance to HIV-1 infection and may modify the course of infection. HLA-B alleles (Bw4 epitope; B*27 and B*57) as well as killer cell immunoglobulin-like receptors have been associated with slow progression of HIV-1 infection. OBJECTIVE: To evaluate the association between serological epitopes HLA-Bw4 and HLA-Bw6 and prognostic markers in AIDS. METHODS: 147 HIV-infected individuals in Bahia, Northeast Brazil, were genotyped for HLA class I locus. HLA class I genotyping was performed by hybridization with sequence-specific oligonucleotide probes following amplification of the corresponding HLA-A, HLA-B and HLA-C genes. Statistical analysis was performed using Fisher's exact and ANOVA tests for categorical and continuous variables, respectively. RESULTS: We detected a significant association (χ2 = 4.856; p = 0.018) between the presence of HLA-Bw4 and low levels of viremia. Eighteen out of the 147 HIV-infected individuals presented viremia <1,800 copies/mL and 129 presented viremia > 2,000 copies/mL. Ninety and four percent (17/18) of all individuals with viremia < 1,800 copies/mL carried HLA-Bw4, compared to 67.4% (87/129) of individuals with viremia > 2,000 copies/mL. Additionally, we found a significantly higher frequency of B*57 (OR = 13.94; 95% CI = 4.19-46.38; p < 0.0001) and Cw*18 (OR = 16.15; 95% CI = 3.46-75.43; p < 0.0001) alleles, favoring the group with lower viremia levels, in comparison with those with higher viral load. CONCLUSION: HLA-Bw4-B*57 and Cw*18 alleles are associated with lower level of viral load in HIV-infected Brazilian patients. These findings may help us in understanding the determinants of HIV evolution in Brazilian patients, as well as in providing important information on immune response correlates of protection for such population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples-1 can be carried out with the proposed flow-batch analyser.