2 resultados para Intergroup Sensitivity Effect

em Universidade Federal do Pará


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Paracoccidioidomycosis is diagnosed from the direct observation of the causative agent, but serology can facilitate and decrease the time required for diagnosis. The objective of this study was to determine the influence of serum sample inactivation on the performance of the latex agglutination test (LAT) for detecting antibodies against Paracoccidioides brasiliensis. The sensitivity of LAT from inactivated or non-inactivated samples was 73% and 83%, respectively and the LAT selectivity was 79% and 90%, respectively. The LAT evaluated here was no more specific than the double-immunodiffusion assay. We suggest the investigation of other methods for improving the LAT, such as the use of deglycosylated antigen.