3 resultados para Automatic Calibration
em Universidade Federal do Pará
Resumo:
ABSTRACT: The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples-1 can be carried out with the proposed flow-batch analyser.
Resumo:
In this letter, a methodology is proposed for automatically (and locally) obtaining the shape factor c for the Gaussian basis functions, for each support domain, in order to increase numerical precision and mainly to avoid matrix inversion impossibilities. The concept of calibration function is introduced, which is used for obtaining c. The methodology developed was applied for a 2-D numerical experiment, which results are compared to analytical solution. This comparison revels that the results associated to the developed methodology are very close to the analytical solution for the entire bandwidth of the excitation pulse. The proposed methodology is called in this work Local Shape Factor Calibration Method (LSFCM).
Resumo:
Utilizando-se dados do campo de Camorim (Bacia de Sergipe-Alagoas), foi testado e aplicado um conjunto de técnicas estatísticas multivariantes (análises de agrupamentos, de componentes principais e discriminante) no intuito de identificar as fácies, previamente definidas em poços testemunhados, por meio dos perfis, viabilizando o reconhecimento das mesmas nos demais poços não testemunhados da área. A segunda etapa do processo de determinação das fácies consistiu no emprego de métodos auxiliares (análises composicional e de seqüência de fácies), que, combinados com as técnicas multivariantes, propiciaram melhores resultados na calibração rocha-perfil. A determinação das fácies, uma vez estabelecida, possibilitou o refinamento do processo de avaliação de formações ao viabilizar o exame de cada fácies-reservatório, isoladamente. Assim, esse procedimento tornou possível a escolha, para cada litologia, dos parâmetros utilizados na interpretação dos perfis ao mesmo tempo em que permitiu a totalização em separado dos valores de espessura, porosidade e saturação dos fluidos, bem como a adoção de diferentes valores de corte (cut-offs) para cada grupo considerado. Outras aplicações incluíram a melhoria na estimativa da porosidade e da permeabilidade, a adaptação de algoritmos para o cálculo preliminar de porosidade, a confecção de mapas de fácies e a geração automática de seções estratigráficas. Finalmente, foram destacadas a perspectiva de integração desse estudo com sistemas estatísticos de descrição de reservatórios, outras técnicas de determinação de fácies em desenvolvimento e a retomada da utilização de métodos estatísticos multivariantes em dados de perfis, como ferramenta de exploração.