172 resultados para Conventional water treatment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new methodology for tree seedling production (Aquaforest system) based on a continuous floating subirrigation system was developed and tested using creeks with different nutrient levels. Eucalyptus grandis seedlings were produced in water from polluted and clean creeks, and compared to conventional tree nursery production. The growth variables analyzed in the seedling phase were: survival, height, diameter, shoot and root dry weight, leaf area, and root/shoot ratio. Water and substrate were analyzed, as well as leaf nutritional status. Plant survival was 100% in all treatments. Height and diameter were greater in the higher nutrient water treatment. Leaf area and dry weight of plants produced in the higher nutrient water treatment were similar to those of the control. The results showed that polluted water can represent a good nutrient source. The preliminary results show that the Aquaforest system can be a viable alternative for tree seedling production. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The microbiological monitoring of the water used for hemodialysis is extremely important, especially because of the debilitated immune system of patients suffering from chronic renal insufficiency. To investigate the occurrence and species diversity of bacteria in waters, water samples were collected monthly from a hemodialysis center in upstate São Paulo and tap water samples at the terminal sites of the distribution system was sampled repeatedly (22 times) at each of five points in the distribution system; a further 36 samples were taken from cannulae in 19 hemodialysis machines that were ready for the next patient, four samples from the reuse system and 13 from the water storage system. To identify bacteria, samples were filtered through 0.22 mu m-pore membranes; for mycobacteria, 0.45 mu m pores were used. Conventional microbiological and molecular methods were used in the analysis. Bacteria were isolated from the distribution system (128 isolates), kidney machine water (43) and reuse system (3). Among these isolates, 32 were Gram-positive rods, 120 Gram-negative rods, 20 Gram-positive cocci and 11 mycobacteria. We propose the continual monitoring of the water supplies in hemodialysis centers and the adoption of effective prophylactic measures that minimize the exposure of these immunodeficient patients to contaminated sources of water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two projects of water treatment for public water supply were developed and operated by using combined systems of constructed wetlands. One of the projects was carried out in the town of Analandia, Sao Paulo, Brazil and wetlands with floating aquatic plants associated to the HDS system were used. Nearly 6480 inhabitants were supplied. The other conducted project was an experimental station in partnership with SABESP (Sao Paulo State Sanitation Agency/Brazil), for the pretreatment of 1700 l.s-1 of waters from the Cotia River, which is used for the population's supply after conventional treatment at the Lower Cotia Water Treatment Station. For this pilot project, wetlands with emergents and floating plants associated to the HDS system were used. The proposed objectives were achieved in both projects.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study shows a possibility of using municipal sewage sludge after thermal treatment in the production of a filtering material to water treatment. Due to the fast urbanization and implementation of high standards for effluent in many countries in recent years, the sewage sludge is being produced in an ever increasing amount. Therefore, the use of sludge is a suitable solution for the expected large quantity of sludge. Dehydration of sludge was performed by controlled heating at temperatures of 1100 degrees C, 850 degrees C, 650 degrees C, 350 degrees C for 3 hours. After thermal treatment the sludge was characterized by X-ray fluorescence, TG/DTG/DTA, residue solubilization and residue lixiviation tests. The aim of the present work was to observe, thought the characterization techniques, if the treated sewage sludge is or not adequate to be used as filter material to water treatment. It will be verified which treatment temperature of the sludge offer possibility to its use in water treatment without carrying pollutants in concentrations out of the standards.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Recently a textile azo dye processing plant effluent was identified as one of the sources of mutagenic activity detected in the Cristais River, a drinking water source in Brazil [G.A. Umbuzeiro, D.A. Roubicek, C.M. Rech, M.I.Z. Sato, L.D. Claxton, Investigating the sources of the mutagenic activity found in a river using the Salmonella assay and different water extraction procedures, Chemosphere 54 (2004) 1589-1597]. Besides presenting high mutagenic activity in the Salmonella/microsome assay, the mutagenic nitro-aminoazobenzenes dyes CI Disperse Blue 373, Cl Disperse Violet 93, and CI Disperse Orange 37 [G.A. Umbuzeiro, H.S. Freeman, S.H. Warren, D.P Oliveira, Y. Terao, T. Watanabe, L.D. Claxton, the contribution of azo dyes in the mutagenic activity of the Cristais river, Chemosphere 60 (2005) 55-64] as well as benzidine, a known carcinogenic compound [T.M. Mazzo, A.A. Saczk, G.A. Umbuzeiro, M.V.B. Zanoni, Analysis of aromatic amines in surface waters receiving wastewater from textile industry by liquid chromatographic with eletrochemical detection, Anal. Lett., in press] were found in this effluent. After similar to 6 km from the discharge of this effluent, a drinking water treatment plant treats and distributes the water to a population of approximate 60,000. As shown previously, the mutagens in the DWTP intake water are not completely removed by the treatment. The water used for human consumption presented mutagenic activity related to nitro-aromatics and aromatic amines compounds probably derived from the cited textile processing plant effluent discharge [G.A. Umbuzeiro, D.A. Roubicek, C.M. Rech, M.I.Z.. Sato, L.D. Claxton, Investigating the sources of the mutagenic activity found in a river using the Salmonella assay and different water extraction procedures, Chemosphere 54 (2004) 1589-1597; G.A. Umbuzeiro, H.S. Freeman, S.H. Warren, D.P. Oliveira, Y. Terao, T. Watanabe, L.D. Claxton, the contribution of azo dyes in the multagenic activity of the Cristais river, Chemosphere 60 (2005) 55-64]. Therefore, it is important to evaluate the possible risks involved in the human consumption of this contaminated water. With that objective, one sample of the cited industrial effluent was tested for carcinogenicity in the aberrant crypt foci medium-term assay in colon of Wistar rats. The rats received the effluent in natura through drinking water at concentrations of 0.1%, 1%, and 10%. The effluent mutagenicity was also confirmed in the Salmonella/microsome assay with the strains TA98 and YG1041. There was an increased number of preneoplastic lesions in the colon of rats exposed to concentrations of 1% and 10% of the effluent, and a positive response for both Salmonella strains tested. These results indicate that the discharge of the effluent should be avoided in waters used for human consumption and show the sensitivity of the ACF crypt foci assay as an important tool to evaluate the carcinogenic potential of environmental complex mixtures. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Water treatment uses chlorine for disinfection causing formation of trihalomethanes. In this work, an electrolytic water pre-treatment was studied and applied to the water from a fountainhead. The action against microorganisms was evaluated using cast-iron and aluminum electrodes. Assays were made in laboratory using the electrolytic treatment. After 5 min of electrolysis the heterotrophic bacteria count was below 500 cfu/mL and complete elimination of total and fecal coliforms was observed. Using electrolytic treatment as a pretreatment of conventional tap water treatment is proposed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Estudou-se o reuso de água de um sistema composto por estação de tratamento de esgoto (ETE) com aeração prolongada e lodo ativado, e em uma estação compacta de tratamento de água (ECTA) de uma indústria metalúrgica. Os processos para obtenção da água de reuso foram: microbiológico e físico-químico. O esgoto doméstico foi bombeado para a ETE, onde houve formação de flocos biológicos e água clarificada. Avaliou-se a eficiência do processo microbiológico da ETE mediante a remoção de demanda bioquímica de oxigênio (DBO), demanda química de oxigênio (DQO) e sólidos sedimentáveis (SS). A eficiência do processo físico-químico de clarificação e desinfecção foi avaliada mediante análises de pH, turbidez, cor, contagem de bactérias heterotróficas aeróbias, cloro livre, dureza, alcalinidade, cloretos, sulfatos, sólidos totais dissolvidos (STD). Na água de reuso além desses parâmetros avaliou-se a toxicidade aguda ao microcrustáceo Daphnia similis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The work reported here involved the characterization of sludges produced at water treatment plants in Jaboticabal-SP using FeCl3 as flocculant, and in Taquaritinga-SP and Manaus-AM using Al2(SO4)3 as flocculant. An evaluation was also made of the interaction of organic matter extracted from the sludges with different metal species. The results indicated that all the sludges produced at water treatment plants have an important agricultural potential and that their use depends on the characteristics of the raw water and the type of flocculant employed in conventional treatment. The humic substances extracted from the sludges showed different affinities for metal species, favoring eventual exchanges between potentially toxic metals and macro- and micronutrients. An alternative for the use of sludge in agriculture is to pretreat it to remove potentially toxic metals and enrich it with micro- and macronutrients that can be released to the plant.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O objetivo do presente artigo é investigar a relação fluorose/cáries em escolas, de acordo com o nível de fluoreto no abastecimento público de água. A amostra consistiu em 360 alunos de doze anos de idade, de ambos os sexos, que frequentam as escolas próximas da região em que nasceram. As escolas foram classificadas em três grupos de acordo com a presença de fluoreto no abastecimento de água: 1) fluoretação na Estação de Tratamento de Água (ETA); 2) fluoretação direta em poços; e 3) áreas não fluoretadas (ANF). Os testes deχe de Goodman (significância = 5%) foram utilizados para avaliar a associação entre a origem da água e o grau de fluorose. Os resultados mais predominantes foram presença de cáries em toda a amostra (P<0,05); ausência de fluorose em ambos gêneros, para indivíduos brancos e aqueles vivendo em áreas abastecidas com água fluoretada diretamente de poços e não fluoretadas (P<0,05). Não houve diferença no grau de severidade da fluorose entre as fontes de abastecimento de água (P>0,05). As cáries ainda são uma importante questão nessa população, apesar do estabelecimento de medida preventiva. A observação da fluorose em alunos vivendo em áreas não fluoretadas confirma a presença de outras fontes de fluorose.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The water produced by the Cristais River Drinking Water Treatment Plant (CR-DWTP) repeatedly produced mutagenic responses that could not be explained by the presence of disinfection byproducts (DBPs) generated by the reaction of humic acids and chlorine. In order to determine the possible role of chlorinated dye products in this mutagenic activity, solutions of a black dye commercial product (BDCP) composed of C. I. Disperse Blue 373, C. I. Disperse Orange 37, C. I. Disperse Violet 93, and chemically reduced BDCP (R-BDCP) were chlorinated in a manner similar to that used by the CR-DWTP. The resulting solutions were extracted with XAD-4 along with one drinking water sample collected from the CR-DWTP. All extracts showed mutagenic activity in the Salmonella/microsome assay. Dye components of the BDCP as well as its reduced chlorinated (Cl-R-BDCP) derivative were detected in the drinking water sample by analysis with a high performance liquid chromatography/diode array detector (HPLC/DAD). The mutagenicity results of these products suggest that they are, at least in part, accounting for the mutagenic activity detected in the drinking water samples from the Cristais River. The data obtained in this study have environmental and health implications because the chlorination of the BDCP and the R-BDCP leads to the formation of mutagenic compounds (Cl-BDCP and Cl-R-BDCP), which are potentially important disinfection byproducts that can contaminate the drinking water as well as the environment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Presented here is a study about the capability of a sensing unit to detect changes in river water quality. In order to determine its accuracy, water quality was monitored at 11 points along the Veado River in Presidente Prudente, Brazil. To have a basis for comparison, a water quality index (WQI) was developed following methods previously applied in different watersheds. Results showed an accurate relationship between WQI and electric impedance readings detected by the sensing unit. Principal components analysis (PCA) was used to derive results in a form that can be correlated with WQI calculated for each sample point, which showed the potential application of this device.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)