63 resultados para parallel operation

em Reposit


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the use of differential evolution ( DE), a global search technique inspired by evolutionary theory, to find the parameters that are required to achieve optimum dynamic response of parallel operation of inverters with no interconnection among the controllers is proposed. Basically, in order to reach such a goal, the system is modeled in a certain way that the slopes of P-omega and Q-V curves are the parameters to be tuned. Such parameters, when properly tuned, result in system's eigenvalues located in positions that assure the system's stability and oscillation-free dynamic response with minimum settling time. This paper describes the modeling approach and provides an overview of the motivation for the optimization and a description of the DE technique. Simulation and experimental results are also presented, and they show the viability of the proposed method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work it is proposed an optimized dynamic response of parallel operation of two single-phase inverters with no control communication. The optimization aims the tuning of the slopes of P-ω and Q-V curves so that the system is stable, damped and minimum settling time. The slopes are tuned using an algorithm based on evolutionary theory. Simulation and experimental results are presented to prove the feasibility of the proposed approach. © 2010 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work, based in a patent request at INPI, protocol no. 020110035974, presents a system development using solar panels to supply the electricity demand required by punctual loads, without a storage unit or utility grid synchronism, through a control circuit that allows parallel operation with the power grid during low sunlight incidence periods. A study about solar panel construction and topologies for Power generation was done, in a atempt to evalute impacts in project. This development was modular, providing the system the possibility of power capacity expansion and load diversity as well, in an attempt to reduce the total energy requirements from the residential sector drained from the power grid along the day

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new methodology for the adjustment of the preheating process and steady-state operation of electronic ballasts intended for hot-cathode fluorescent lamps. The classical series-resonant parallel-loaded half-bridge inverter is the power stage analyzed in this paper. In addition, the preheating process is based on the imposition of a constant rms current through the electrodes, in order to provide a proper value of the R-h/R-c ratio before the lamp start. According to the proposed methodology, it is possible to set suitable operating points for, the electronic ballast, considering optimal conditions for the lamps electrodes. Therefore, the proposed methodology for setting the preheating and steady-state operation is a complete platform to the design of electronic ballasts for hot-cathode fluorescent lamps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The analysis of alcoholic beverages for the important carcinogenic contaminant ethyl carbamate is very time-consuming and expensive. Due to possible matrix interferences, sample cleanup using diatomaceous earth (Extrelut) column is required prior to gas chromatographic and mass spectrometric measurement. A limiting step in this process is the rotary evaporation of the eluate containing the analyte in organic solvents, which is currently conducted manually and requires approximately 20-30 min per sample. This paper introduces the use of a parallel evaporation device for ethyl carbamate analysis, which allows for the simultaneous evaporation of 12 samples to a specified residual volume without manual intervention. A more efficient and, less expensive analysis is therefore possible. The method validation showed no differences between the fully-automated parallel evaporation and the manual operation. The applicability was proven by analyzing authentic spirit samples from Germany, Canada and Brazil. It is interesting to note that Brazilian cachacas had a relatively high incidence for ethyl carbamate contamination (55% of all samples were above 0.15 mg/l), which may be of public health relevance and requires further evaluation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new methodology for the determination of fluorescent lamp models based on equivalent resistances. One important feature of the proposed methodology is concerned with the inclusion of the filaments into the model, considering the effects of dimming operation on the equivalent resistances. The classical Series-Resonant Parallel-Loaded Half-Bridge inverter is used as the power stage of the ballast. Moreover, the variation of the inverter's switching frequency is the dimming technique assumed for the analyses. Results obtained with a F32T8 lamp indicate that the accuracy of the model is very satisfactory. Thus, the lamp models obtained with the proposed methodology have the potential to serve as an important tool for ballast designers, considering the necessity for evaluating the lamp/ballast compatibility, according to issues concerned to the operating conditions of the electrodes' filaments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The resistive-type superconducting fault current limiters (RSFCL) prototypes using YBCO-coated conductors have shown current limitation for medium voltage class applications for acting time up to 80 ms. By connecting an air-core reactor in parallel with the RSFCL, thus making an hybrid current limiter, one can extend the acting time for up to 1 s. In this work, we report the performance of a hybrid current limiter subjected to an AC peak fault current of 2 kA during 1 s for which within the first 80 ms the SFCL limits the current concurrently with the air-core reactor, and for the remaining 920 ms, only the air-core reactor limits the current. In order to evaluate the actual conditions for subsequent reconnection of RSFCL to the power grid, the hybrid fault current limiter was tested varying the time interval for recovery from 900 ms and 1.2 s, followed again by the concurrent operation of the hybrid limiter during 1 s (SFCL during 80 ms). From this evaluation test, the recovery time can be measured and compared using the voltage peak generated in superconducting module from the first and second fault test. The recovery time was also determined through the pulsed current method (PCM) on short-length sample test. The results showed that the fault current was limited from 1.9 kA down to 514 A after 1 cycle of 60 Hz frequency, with recovery time lower than 1.2 s for two subsequent fault current tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a methodology for automatic extraction of road segments from images with different resolutions (low, middle and high resolution) is presented. It is based on a generalized concept of lines in digital images, by which lines can be described by the centerlines of two parallel edges. In the specific case of low resolution images, where roads are manifested as entities of 1 or 2 pixels wide, the proposed methodology combines an automatic image enhancement operation with the following strategies: automatic selection of the hysteresis thresholds and the Gaussian scale factor; line length thresholding; and polygonization. In medium and high resolution images roads manifest as narrow and elongated ribbons and, consequently, the extraction goal becomes the road centerlines. In this case, it is not necessary to apply the previous enhancement step used to enhance roads in low resolution images. The results obtained in the experimental evaluation satisfied all criteria established for the efficient extraction of road segments from different resolution images, providing satisfactory results in a completely automatic way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows the design, simulation, and analysis of two optical interconnection networks for a Dataflow parallel computer architecture. To verify the optical interconnection network performance on the Dataflow architecture, we have analyzed the load balancing among the processors during the parallel programs executions. The load balancing is a very important parameter because it is directly associated to the dataflow parallelism degree. This article proves that optical interconnection networks designed with simple optical devices can provide efficiently the dataflow requirements of a high performance communication system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results are presented and discussed of an experimental investigation on acetylene turbulent dual jet diffusion flames. The study includes parameters of flames in parallel, divergent and convergent configurations. Tests with two parallel jets with addition of helium in the fuel stream were also performed and analysed. The variation of overall flame length and of other name physical characteristics, such as width, volume and conditions for lifting, are presented as functions of burner tip Reynolds number, jet distance from each other and inclination angle. The effects of diluent concentration in the fuel gas stream are presented for single and two parallel jets. (C) 1999 Elsevier B.V. Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is based on the development and experimental analysis of a DCM Boost interleaved converter suitable for application in traction systems of electrical vehicles pulled by electrical motors (Trolleybus), which are powered by urban DC or AC distribution networks. This front-end structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The architecture of proposed converter is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode. Furthermore, the converter can operate as AC-DC converter, or as DC-DC converter providing the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards. The digital controller has been implemented using a low cost FPGA and developed totally using a hardware description language VHDL and fixed point arithmetic. Thus, two control strategies are evaluated considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, the regular PWM modulation and a current correction PWM modulation. In order to verify the feasibility and performance of the proposed system, experimental results from a 15 kW low power scale prototype are presented, operating in DC and AC conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)