56 resultados para parallel bridge

em Reposit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows the design, simulation, and analysis of two optical interconnection networks for a Dataflow parallel computer architecture. To verify the optical interconnection network performance on the Dataflow architecture, we have analyzed the load balancing among the processors during the parallel programs executions. The load balancing is a very important parameter because it is directly associated to the dataflow parallelism degree. This article proves that optical interconnection networks designed with simple optical devices can provide efficiently the dataflow requirements of a high performance communication system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results are presented and discussed of an experimental investigation on acetylene turbulent dual jet diffusion flames. The study includes parameters of flames in parallel, divergent and convergent configurations. Tests with two parallel jets with addition of helium in the fuel stream were also performed and analysed. The variation of overall flame length and of other name physical characteristics, such as width, volume and conditions for lifting, are presented as functions of burner tip Reynolds number, jet distance from each other and inclination angle. The effects of diluent concentration in the fuel gas stream are presented for single and two parallel jets. (C) 1999 Elsevier B.V. Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new methodology for the adjustment of the preheating process and steady-state operation of electronic ballasts intended for hot-cathode fluorescent lamps. The classical series-resonant parallel-loaded half-bridge inverter is the power stage analyzed in this paper. In addition, the preheating process is based on the imposition of a constant rms current through the electrodes, in order to provide a proper value of the R-h/R-c ratio before the lamp start. According to the proposed methodology, it is possible to set suitable operating points for, the electronic ballast, considering optimal conditions for the lamps electrodes. Therefore, the proposed methodology for setting the preheating and steady-state operation is a complete platform to the design of electronic ballasts for hot-cathode fluorescent lamps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the use of differential evolution ( DE), a global search technique inspired by evolutionary theory, to find the parameters that are required to achieve optimum dynamic response of parallel operation of inverters with no interconnection among the controllers is proposed. Basically, in order to reach such a goal, the system is modeled in a certain way that the slopes of P-omega and Q-V curves are the parameters to be tuned. Such parameters, when properly tuned, result in system's eigenvalues located in positions that assure the system's stability and oscillation-free dynamic response with minimum settling time. This paper describes the modeling approach and provides an overview of the motivation for the optimization and a description of the DE technique. Simulation and experimental results are also presented, and they show the viability of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a consistent and concise analysis of the free and forced vibration of a mass supported by a parallel combination of a spring and an elastically supported damper (a Zener model). The results are presented in a compact form and the physical behaviour of the system is emphasised. This system is very similar to the conventional single-degree-of freedom system (sdof)-(Voigt model), but the dynamics can be quite different depending on the system parameters. The usefulness of the additional spring in series with the damper is investigated, and optimum damping values for the system subject to different types of excitation are determined and compared.There are three roots to the characteristic equation for the Zener model; two are complex conjugates and the third is purely real. It is shown that it is not possible to achieve critical damping of the complex roots unless the additional stiffness is at least eight times that of the main spring. For a harmonically excited system, there are some possible advantages in using the additional spring when the transmitted force to the base is of interest, but when the displacement response of the system is of interest then the benefits are marginal. It is shown that the additional spring affords no advantages when the system is excited by white noise. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of alcoholic beverages for the important carcinogenic contaminant ethyl carbamate is very time-consuming and expensive. Due to possible matrix interferences, sample cleanup using diatomaceous earth (Extrelut) column is required prior to gas chromatographic and mass spectrometric measurement. A limiting step in this process is the rotary evaporation of the eluate containing the analyte in organic solvents, which is currently conducted manually and requires approximately 20-30 min per sample. This paper introduces the use of a parallel evaporation device for ethyl carbamate analysis, which allows for the simultaneous evaporation of 12 samples to a specified residual volume without manual intervention. A more efficient and, less expensive analysis is therefore possible. The method validation showed no differences between the fully-automated parallel evaporation and the manual operation. The applicability was proven by analyzing authentic spirit samples from Germany, Canada and Brazil. It is interesting to note that Brazilian cachacas had a relatively high incidence for ethyl carbamate contamination (55% of all samples were above 0.15 mg/l), which may be of public health relevance and requires further evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mucosal bridges are rare laryngeal lesions probably of genetic origin. They may cause dysphonia of varying degrees, especially when associated with other laryngeal lesions such as vocal sulci and cysts. Reports on mucosal bridges are rare, and the better treatment is inconclusive.Aim. To report the authors' experience in 14 cases of mucosal bridge showing details on endoscopic examinations and treatment.Study Design. Retrospective study.Methods. We reviewed the medical records of 14 patients with a diagnosis of mucosal bridge confirmed by video-laryngostroboscopy and direct laryngoscopy who attended the Outpatient Clinic of Voice Disorders of the Discipline of Otorhinolaryngology, Botucatu Medical School, São Paulo State University, São Paulo. Data collected included information on gender, age, symptoms, time of onset, history of intubation, smoking status, alcohol intake, associated laryngeal lesions, treatment, and GRBAS (grade of hoarseness, roughness, breathiness, asthenia, and stress) scale ratings.Results. of 14 patients, 10 were females and four were males. There was a prevalence of adults (n = 12), with only two of the patients being younger than 13 years (10 and 13 years). Mucosal bridges showed no correlations with smoking, alcohol intake, or gastroesophageal and sinonasal symptoms. Voice abuse was reported in 50% of the cases that consisted of patients who had high-voice demand occupations. In seven cases, mucosal bridges were associated with other laryngeal lesions, particularly vocal cysts and sulci. All patients who underwent surgery and phonotherapy showed improved vocal quality.Conclusions. We documented 14 patients with dysphonia caused by mucosal bridge. Promising results were obtained with surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thorough study of the thermal performance of multipass parallel cross-flow and counter-cross-flow heat exchangers has been carried out by applying a new numerical procedure. According to this procedure, the heat exchanger is discretized into small elements following the tube-side fluid circuits. Each element is itself a one-pass mixed-unmixed cross-flow heat exchanger. Simulated results have been validated through comparisons to results from analytical solutions for one- to four-pass, parallel cross-flow and counter-cross-flow arrangements. Very accurate results have been obtained over wide ranges of NTU (number of transfer units) and C* (heat capacity rate ratio) values. New effectiveness data for the aforementioned configurations and a higher number of tube passes is presented along with data for a complex flow configuration proposed elsewhere. The proposed procedure constitutes a useful research tool both for theoretical and experimental studies of cross-flow heat exchangers thermal performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electronic ballast for multiple tubular fluorescent lamp systems is presented. The proposed structure has a high value for the power factor, a dimming capability, and soft switching of the semiconductor devices operated at high frequencies. A zero-current switching pulse width modulated SEPIC converter is used as the rectifying stage and it is controlled using the instantaneous average input current technique. The inverting stage consists of classical resonant half-bridge converter with series-resonant parallel-loaded filters. The dimming control technique is based on varying the switching frequency and monitoring the phase shift of the current drained by the filters and lamps in order to establish a closed loop control. Experimental results are presented that validate the theoretical analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we consider the extension of the Brandt theory of elasticity of the Abrikosov flux-line lattice for a uniaxial superconductor for the case of parallel flux lines. The results show that the effect of the anisotropy is to rescale the components of the wave vector k and the magnetic field and order-parameter wave vector cut off by a geometrical parameter previously introduced by Kogan.