148 resultados para diode array detector

em Reposit


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and rapid method was developed for determination of 8 carbamate insecticides and 10 of their metabolites in apples, pears, and lettuce by liquid chromatography with UV diode array detector. With this method no derivatization is needed. Carbamates not belonging to the N-methylcarbamate class and metabolites without the N-methyl group can also be determined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simultaneous method for the trace determination of acidic, neutral herbicides and their transformation products in estuarine waters has been developed through an on-line solid-phase extraction method followed by liquid chromatography with diode array and mass spectrometric detection. An atmospheric pressure chemical ionization (APCI) interface was used in the negative ionization mode after optimization of the main APCI parameters. Limits of detection ranged from 0.1 to 0.02 ng/ml for 50 mi of acidified estuarine waters preconcentrated into polymeric precolumns and using time-scheduled selected ion monitoring mode. Two degradation products of the acidic herbicides (4-chloro-2-methylphenol and 2,4-dichlorophenol) did not show good signal response using APCI-MS at the concentration studied due to the higher fragmentor voltage needed for their determination For molinate and the major degradation product of propanil, 3,4-dichloroaniline, positive ion mode was needed for APCI-MS detection. The proposed method was applied to the determination of herbicides in drainage waters from rice fields of the Delta del Ebro (Spain). During the S-month monitoring of the herbicides, 8-hydroxybentazone and 4-chloro-2-methylphenoxyacetic acid were successively found in those samples. (C) 2000 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A reversed phase liquid chromatographic method was developed for the simultaneous determination of carboxylic acids and phenolics in white wines. The samples, diluted, were injected onto a Spherisorb ODS-2 column with a gradient of sulfuric acid (pH 2.5)/methanol as mobile phase. A diode array detector was used which was set at 210nm for carboxylic acids and altered to 278nm, during the run, far phenolics and sorbic acid. The identification of compounds was based on retention time, co-chromatography and UV spectrum. Some clean-up methods (sep-pak C-18 and an ion exchange column) mere tested and did not improve the results.The analysis was simple, with no sample preparation. Application of this method was illustrated by analyses of Brazilian Welchriesling wines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The water produced by the Cristais River Drinking Water Treatment Plant (CR-DWTP) repeatedly produced mutagenic responses that could not be explained by the presence of disinfection byproducts (DBPs) generated by the reaction of humic acids and chlorine. In order to determine the possible role of chlorinated dye products in this mutagenic activity, solutions of a black dye commercial product (BDCP) composed of C. I. Disperse Blue 373, C. I. Disperse Orange 37, C. I. Disperse Violet 93, and chemically reduced BDCP (R-BDCP) were chlorinated in a manner similar to that used by the CR-DWTP. The resulting solutions were extracted with XAD-4 along with one drinking water sample collected from the CR-DWTP. All extracts showed mutagenic activity in the Salmonella/microsome assay. Dye components of the BDCP as well as its reduced chlorinated (Cl-R-BDCP) derivative were detected in the drinking water sample by analysis with a high performance liquid chromatography/diode array detector (HPLC/DAD). The mutagenicity results of these products suggest that they are, at least in part, accounting for the mutagenic activity detected in the drinking water samples from the Cristais River. The data obtained in this study have environmental and health implications because the chlorination of the BDCP and the R-BDCP leads to the formation of mutagenic compounds (Cl-BDCP and Cl-R-BDCP), which are potentially important disinfection byproducts that can contaminate the drinking water as well as the environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One hundred and eleven samples of processed fruit juices (apple, grape, pineapple, papaya, guava, banana and mango) and 38 samples of sound fruits (apple, papaya, mango, pear and peach) produced and marketed in Brazil, were analysed for patulin by HPLC. Only one out of 30 samples of apple juice was found positive at 17 μg/l. Patulin was not detected in the other foodstuffs. It was found in 14 samples of spoiled fruit samples of apple (150-267 μg/kg), pear (134-245 μg/kg) and peach (92-174 μg/kg). Confirmation of the identity of patulin was based on the UV spectrum obtained by the HPLC diode array detector, compared with that of standard patulin, TLC developed by several solvent systems and sprayed with 3-methyl-2-benzothiazolinone hydrazone, and by acetylation with acetic anhydride.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Casearia sylvestris Swartz (Salicaceae) is a tree or shrub distributed widely in Brazil, where it is used in popular medicine. Several bioactive clerodane diterpenes typical of Casearia have been isolated from this species (e.g. casearins and casearvestrins). The main objective of this study was to identify clerodane diterpenes in various organs of C. sylvestris, using chromatographic and spectroscopic analytical techniques. The extracts of the different plant parts were analyzed by thin layer chromatography, high performance liquid chromatography with diode array detector and 1H nuclear magnetic resonance. In the chromatographic analysis, clerodane diterpenes isolated from C. sylvestris were used as standards, including rel-19Sacetóxi-18R- butanoilóxi-18,19- epóxi -6S -hidróxi -2R-(2-metilbutanoilóxi) -5S, 8R, 9R, 10S -cleroda-3,13(16),14-triene, isolated for the first time from the stems. Phytochemical profiles of the organs were produced, which indicated the presence of clerodane diterpenes in all parts of the plant, notably in the leaves. The results also suggest that the main clerodane diterpenes in the stems, flowers and roots had conjugated double-bond patterns that differed from those found in the leaves.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The recovery of phenolic compounds of Eugenia pyriformis using different solvents was investigated in this study. The compounds were identified and quantified by reverse-phase high-performance liquid chromatography coupled with ultraviolet-visible diode-array detector (RP-HPLC-DAD/UV-vis). Absolute methanol was the most effective extraction agent of phenolic acids and flavonols (588.31 mg/Kg) from Eugenia pyriformis, although similar results (p ≤ 0.05) were observed using methanol/water (1:1 ratio). Our results clearly showed that higher contents of phenolic compounds were not obtained either with the most or the least polar solvents used. Several phenolic compounds were identified in the samples whereas gallic acid and quercetin were the major compounds recovered. © 2012 Association of Food Scientists & Technologists (India).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Jatropha gossypifolia has been used quite extensively by traditional medicine for the treatment of several diseases in South America and Africa. This medicinal plant has therapeutic potential as a phytomedicine and therefore the establishment of innovative analytical methods to characterise their active components is crucial to the future development of a quality product. Objective To enhance the chromatographic resolution of HPLC-UV-diode-array detector (DAD) experiments applying chemometric tools. Methods Crude leave extracts from J. gossypifolia were analysed by HPLC-DAD. A chromatographic band deconvolution method was designed and applied using interval multivariate curve resolution by alternating least squares (MCR-ALS). Results The MCR-ALS method allowed the deconvolution from up to 117% more bands, compared with the original HPLC-DAD experiments, even in regions where the UV spectra showed high similarity. The method assisted in the dereplication of three C-glycosylflavones isomers: vitexin/isovitexin, orientin/homorientin and schaftoside/isoschaftoside. Conclusion The MCR-ALS method is shown to be a powerful tool to solve problems of chromatographic band overlapping from complex mixtures such as natural crude samples. Copyright © 2013 John Wiley & Sons, Ltd. Extracts from J. gossypifolia were analyzed by HPLC-DAD and, dereplicated applying MCR-ALS. The method assisted in the detection of three C-glycosylflavones isomers: vitexin/isovitexin, orientin/homorientin and schaftoside/isoschaftoside. The application of MCR-ALS allowed solving problems of chromatographic band overlapping from complex mixtures such as natural crude samples. Copyright © 2013 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)