13 resultados para Reflection Method

em Reposit


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work it is introduced a new approach to calculate the density of liquids in terms of the energies of the acoustic signals. This method is compared to other methods in the time domain (peak-to-peak amplitudes) and frequency domain magnitudes at a single frequency. It is used a measurement cell based on a multiple reflection technique, and it is developed an acoustic model for the cell. Simulations and experiments using several liquids are presented, showing that the energy method a less sensitive to noise than the other techniques. The relative errors in the density are smaller than 0.2% when compared to the values measured with a pycnometer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Successful application of shallow seismic reflection method is related directly to the ability of the ground to transmit high-frequency seismic energy from a seismic source. The dominant frequencies of reflection data are in the range of 50 to 100 Hz and depend on the surface materials and water table. A spread of geophones send the siemsic signal to be recorded on a 12, 24 or 48 channel portable seismograph, using a single high-frequency geophone per channel. Although it is possible to find seismographs with display and processing unities, it is also possible to transfer digitalized data to a personal computer to be processed and interpreted by using specific programs. Some results of two recent field studies to specify the underground structure in the tidal flats area of Baie St. Paul (Quebec-Canada) and in glacial terrains, in the Waterloo (Ontario-Canada) region. -from English summary

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents recent improvements in a density measurement cell with a double-element transducer that can eliminate diffraction effects. A new mechanical design combined with the use of more appropriate materials has resulted in better parallelism between interfaces, more robust assembly, and chemical resistance. A novel method of signal processing, named energy method, is introduced to obtain the reflection coefficient, reducing sensitivity to noise and improving accuracy. The measurement cell operation is verified both theoretically, using an acoustic wave propagation model, and experimentally, using homogeneous liquids with different densities. The accuracy in the density measurement is 0.2% when compared with the measurements made with a pycnometer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Saliva has become an important resource for evaluating physiological and pathological conditions in humans. The use of saliva has many advantages, including the simple and non-invasive method of collection and its easy, low-cost storage. With the addition of modern techniques and chemical instrumentation equipment, there has been an increase in its use for laboratory investigations, applicable for basic and clinical analyses in the fields of medicine and dentistry. The value of these methods for the diagnosis of oral and systemic diseases has been the subject of study by several researchers with the aim of increasing its use alongside complementary exams. (C) 2009 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to evaluate the use of shallow seismic technique to delineate geological and geotechnical features up to 40 meters depth in noisy urban areas covered with asphalt pavement, five survey lines were conducted in the metropolitan area of São Paulo City. The data were acquired using a 24-bit, 24-channel seismograph, 30 and 100 Hz geophones and a sledgehammer-plate system as seismic source. Seismic reflection data were recorded using a CMP (common mid point) acquisition method. The processing routine consisted of: prestack band-pass filtering (90-250 Hz); automatic gain control (AGC); muting (digital zeroin) of dead/noisy traces, ground roll, air-wave and refracted-wave; CMP sorting; velocity analyses; normal move-out corrections; residual static corrections; f-k filtering; CMP stacking. The near surface is geologically characterized by unconsolidated fill materials and Quaternary sediments with organic material overlying Tertiary sediments with the water table 2 to 5 m below the surface. The basement is composed of granite and gneiss. Reflections were observed from 40 milliseconds to 65 ms two-way traveltime and were related to the silt clay layer and fine sand layer contact of the Tertiary sediments and to the weathered basement. The CMP seismic-reflection technique has been shown to be useful for mapping the sedimentary layers and the bedrock of the São Paulo sedimentary basin for the purposes of shallow investigations related to engineering problems. In spite of the strong cultural noise observed in these urban areas and problems with planting geophones we verified that, with the proper equipment, field parameters and particularly great care in data collection and processing, we can overcome the adverse field conditions and to image reflections from layers as shallow as 20 meters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents the implementation of the ultrasonic shear reflectance method for viscosity measurement of Newtonian liquids using wave mode conversion from longitudinal to shear waves and vice-versa. The method is based on measuring the complex reflection coefficient (magnitude and phase) at a solid-liquid interface. Viscosity measurements were made in the range from 1 to 3.5MHz at 22.5°C for automotive oil (SAE40) and at 15°C for olive oil. Moreover, measurements of the olive oil were also conducted in the range from 15 to 30°C at 3.5MHz. The experimental results agree with those provided by a rotational viscometer. © 2006 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The determination of the reflection coefficient of shear waves reflected from a solid-liquid interface is an important method in order to study the viscoelastic properties of liquids at high frequency. The reflection coefficient is a complex number. While the magnitude measurement is relatively easy and precise, the phase measurement is very difficult due to its strong temperature dependence. For that reason, most authors choose a simplified method in order to obtain the viscoelastic properties of liquids from the measured coefficient. In this simplified method, inconsistent viscosity results are obtained because pure viscous behavior is assumed and the phase is not measured. This work deals with an effort to improve the experimental technique required to measure both the magnitude and phase of the reflection coefficient and it intends to report realistic values for oils in a wide range of viscosity (0.092 - 6.7 Pa.s). Moreover, a device calibration process is investigated in order to monitor the dynamic viscosity of the liquid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The X-ray Fluorescence (XRF) analysis is a technique for the qualitative and quantitative determination of chemical constituents in a sample. This method is based on detection of the characteristic radiation intensities emitted by the elements of the sample, when properly excited. A variant of this technique is the Total Reflection X-ray Fluorescence (TXRF) that utilizes electromagnetic radiation as excitation source. In total reflection of X-ray, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample support interface. Thus, there is a minimum angle of incidence at which no refracted beam exists and all incident radiation undergoes total reflection. In this study, we evaluated the influence of the energy variation of the beam of incident x-rays, using the MCNPX code (Monte Carlo NParticle) based on Monte Carlo method. © 2013 AIP Publishing LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel method of preparation of the Si nanoparticles (NPs) incorporated in tellurite TeO2-WO3-Bi2O3 (TWB) thin films is proposed. This mew method applies RF magnetron sputtering technique at room temperature. The incorporation of Si NP was confirmed by transmission electron microscopy (TEM); isolated Si NPs with diameters of around 6 nm are observed. Energy dispersive X-ray spectroscopy (EDS) was performed during TEM analysis in order to confirm the presence of Si NP and also the other elements of the thin film. The thin films are explored with respect to the photoinduced changes of the reflectivity within the 400-65 nm spectra range using a 10 ns pulsed Nd:YAG with power densities varying up to 400 MW/cm2 and beam diameter within the 3-5 mm range. The observed processes are analyzed within a framework of trapping level conceptions for the Si NP. The possible application of the discovered materials as optical sensitive sensors is proposed. © 2013 Elsevier B.V.