128 resultados para Quantification methodologies

em Reposit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study we evaluated the precision of the ELISA method to quantify caffeine in human plasma and compared the results with those obtained by gas chromatography. A total of 58 samples were analyzed by gas chromatography using a nitrogen-phosphorus detector and routine techniques. For the ELISA test, the samples were diluted to obtain a concentration corresponding to 50% of the absorbance of the standard curve. To determine whether the proximity between the I50 of the standard curve and that of the sample would bring about a more precise result, the samples were divided into three blocks according to the criterion of difference, in modulus, of the I50 of the standard curve and of the I50 of the sample. The samples were classified into three groups. The first was composed of 20 samples with I50 up to 1.5 ng/ml, the second consisted of 21 samples with I50 ranging from 1.51 to 3 ng/ml, and the third of 17 samples with I50 ranging from 3.01 to 13 ng/ml. The determination coefficient (R² = 0.999) showed that the data obtained by gas chromatography represented a reliable basis. The results obtained by ELISA were also reliable, with an estimated Pearson correlation coefficient of 0.82 between the two methods. This coefficient for the different groups (0.88, 0.79 and 0.49 for groups 1, 2 and 3, respectively) showed greater reliability for the test with dilutions closer to I50.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the accuracy of a number of methodologies, i.e. PLANIMETER, GEOMETRIC, GRID, UNESP-GRID, UFSM, ZEISS and DELTA-T, in determining ribeye area (REA) of 65 Saanen goats of varying body condition. Goats were grouped according to body weight at slaughter (5.3, 11.2, 12.9, 16.4, 21.0, 22.1, 27.7, 28.6 and 35.2kg). Tracing based on transverse section between the 13th thoracic and I st lumbar vertebrae was used to determinate REA. There was no significant interaction between methodologies and body weight at slaughter. PLANIMETER, UNESP-GRID, GEOMETRIC and UFSM methods were similar in average values to the standard DELTA-T method. The REA was overestimated by the GRID and underestimated by the ZEISS method. The UNESP-GRID, GEOMETRIC and UFSM methods have coincident curves comparable to DELTA-T, when used to estimate goat REA. The UNESP-GRID and GEOMETRIC were the methods of choice based on accuracy, practicality and feasibility. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O desenvolvimento de projetos relacionados ao desempenho de diversas culturas tem recebido aperfeiçoamento cada vez maior, incorporado a modelos matemáticos sendo indispensável à utilização de equações cada vez mais consistentes que possibilitem previsão e maior aproximação do comportamento real, diminuindo o erro na obtenção das estimativas. Entre as operações unitárias que demandam maior estudo estão aquelas relacionadas com o crescimento da cultura, caracterizadas pela temperatura ideal para o acréscimo de matéria seca. Pelo amplo uso dos métodos matemáticos na representação, análise e obtenção de estimativas de graus-dia, juntamente com a grande importância que a cultura da cana-de-açúcar tem para a economia brasileira, foi realizada uma avaliação dos modelos matemáticos comumente usados e dos métodos numéricos de integração na estimativa da disponibilidade de graus-dia para essa cultura, na região de Botucatu, Estado de São Paulo. Os modelos de integração, com discretização de 6 em 6 h, apresentaram resultados satisfatórios na estimativa de graus-dia. As metodologias tradicionais apresentaram desempenhos satisfatórios quanto à estimativa de grausdia com base na curva de temperatura horária para cada dia e para os agrupamentos de três, sete, 15 e 30 dias. Pelo método numérico de integração, a região de Botucatu, Estado de São Paulo, apresentou disponibilidade térmica anual média de 1.070,6 GD para a cultura da cana-de-açúcar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering that counting the percentage of CD4 T lymphocytes can add prognostic information regarding patients infected with HIV, the aim of this study was to evaluate the percentage values of CD4+ T lymphocytes from 81 patients determined by flow cytometry and estimated by flow cytometry in conjunction with a hematology counter. Means were compared through the Student's t-test. Pearson's correlation was determined, and the agreement between results was tested by Bland-Altman. The level of significance was P < 0.05. It was found a significantly higher mean difference between the relative values of CD4+ T lymphocytes to the hematologic counter (P < 0.05), for all strata studied. Positive and significant correlations (P < 0.01) were found between the strata CD4 < 200 cells/mL (r = 0.93), between 200 and 500 cells/mL (r = 0.65), and >500 cells/mL (r = 0.81). The limits of agreement were 1.0 +/- 3.8% for the stratum of CD4 < 200 cells/mL, approximately 2.2 +/- 13.5% for the stratum of CD4 between 200 and 500 cells/mL, and approximately 6.2 +/- 20.4% for the stratum > 500 cells/mL. The differences in the percentages of CD4+ T lymphocytes obtained by different methodologies could lead to conflict when used in clinical decisions related to the treatment and care of people infected with HIV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Propolis obtained from honeybee hives has been widely used in medicine, cosmetics, and industry due to its versatile biological activities (antioxidant, antimicrobial, fungicidal, antiviral, antiulcer, immunostimulating, and cytostatic). These activities are mainly attributed to the presence of flavonoids in propolis, which points out the interest in quantifying these constituents in propolis preparations, as well as validation of analytical methodologies. High-performance liquid chromatography (HPLC) methods have been reported to quantify isolated flavonoids or these compounds in complex biological matrices, such as herbal raw materials and extractive preparations. An efficient, precise, and reliable method was developed for quantification of propolis extractive solution using HPLC with UV detection. The chromatograms were obtained from various gradient elution systems (GES) tested in order to establish the ideal conditions for the analysis of propolis extractive solution, using methanol and water: acetonitrile (97.5 : 2.5, v/v) as mobile phase. Gradient reversed phase chromatography was performed using a stainless steel column (250 x 4.6 mm i.d., 5 mum) filled with Chromsep RP 18 (Varian), column temperature at 30.0 +/- 0.1degreesC and detection at 310 nm. The main validation parameters of the method were also determined. The method showed linearity for chrysin in the range 0.24-2.4 mug mL(-1) with good correlation coefficients (0.9975). Precision and accuracy were determined. The obtained results demonstrate the efficiency of the proposed method. The analytical procedure is reliable and offers advantages in terms of speed and cost of reagents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The carotenoid composition of Brazilian Valencia orange juice was determined by open column chromatography (OCC) and high-performance liquid chromatography. Carotenoid pigments were extracted using acetone and saponified using 10% methanolic potassium hydroxide. Sixteen pigments were isolated by OCC and identified as alpha-carotene, zeta-carotene, beta-carotene, alpha-cryptoxanthin, beta-cryptoxanthin, lutein-5,6-epoxide, violaxanthin, lutein, antheraxanthin, zeaxanthin, luteoxanthin A, luteoxanthin B, mutatoxanthin A, mutatoxanthin B, auroxanthin B and trollichrome B. Thirteen carotenoid pigments were separated using a ternary gradient (acetonitrile-methanol-ethyl acetate) elution on a C-18 reversed-phase column. Among these, violaxanthin, lutein, zeaxanthin, beta-cryptoxanthin, zeta-carotene, alpha-carotene, and beta-carotene were quantified. The total carotenoid content was 12 +/- 6.7 mg/1, and the major carotenoids were lutein (23%), beta-cryptoxanthin (21%), and zeaxanthin (20%). 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fifteen stallions of different breeds, age 3-11 years, had their right testicles evaluated by fine needle aspiration cytology (FNAC). Cytological analysis showed the following spermatogenic cell types: spermatogonia (1.6% +/- 1.1); spermatocyte I (3.4% +/- 2.2); spermatocyte II (0.8% +/- 0.7); early spermatids (25.5% +/- 9.5); late spermatids (37.0% +/- 9.3). Spermatozoal numbers were expressed as the spermatic index (SI = 31.5% +/- 8.5) and Sertoli cells mere expressed as the Sertoli cell index (SEI = 20.9% +/- 17.0) (means +/- s.d). Identification of cell types was relatively easy and no immediate adverse effects of aspiration were noted. The results suggest that FNAC of testis may assist clinical diagnosis in the study of male equine infertility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Levels of rabies virus neutralization antibody in sera from vaccinated dogs and cattle were either measured by mouse neutralization test (MNT) or by rapid fluorescent focus inhibition test (RFFIT), performed on CER monolayers. The two tests were compared for their ability to detect the 0.5 International Units/ml (I.U.) recommended by the World Health Organization (WHO) as the minimum response for proof of rabies immunization. A significant correlation was found between the two tests (n = 211; r = 0.9949 in dogs and 0.9307 in cows, p < 0.001), good sensitivity (87.5%), specificity (94.7%) and agreement (96.6%) as well. RFFIT method standardized on CER cell system for neutralizing antibodies detection turns the diagnosis easier and less expensive, specially when a great number of samples must be tested from endemic areas as commonly found in Brazil. (c) 2005 the International Association for Biologicals. Published by Elsevier Ltd. All rights reserved.