56 resultados para PRESSURE MEASUREMENTS
em Reposit
Resumo:
The effects of propofol on intraocular pressure (IOP) and end tidal CO2 (ETCO2) were studied because an elevation in the latter may alter IOP. Twenty dogs were divided into two groups (G1 and G2). G1 dogs were induced with 10 mg/kg (IV) of propofol followed by a 0.4 mg/kg/min continuous infusion of the same agent diluted in a 0.2% dextrose solution for 1 h. G(CAPS) 2 dogs served as the control group, where only dextrose solution was administered, under the same time intervals as in G1. Applanation tonometry (Tono-Pen) was used to determine IOP and ETCO2 as a method to determine partial CO2 pressure. Measurements were taken every 15 min for 1 h, with M1 occurring immediately before IV administration. IOP and ETCO2 were not statistically significant in either groups. Based on the results, it may be concluded that propofol does not alter IOP and ETCO2.
Resumo:
Objectives: Assess the effect of re-expansive respiratory patterns associated to respiratory biofeedback (RBF) on pulmonary function, respiratory muscle strength and habits in individuals with functional mouth breathing (FMB).Methods: Sixty children with FMB were divided into experimental and control groups. The experimental group was submitted to 15 sessions of re-expansive respiratory patterns associated to RBF (biofeedback pletsmovent; MICROHARD (R) V1.0), which provided biofeedback of the thoracic and abdominal movements. The control group was submitted to 15 sessions using biofeedback alone. Spirometry, maximum static respiratory pressure measurements and questions regarding habits (answered by parents/guardians) were carried out before and after therapy. The Student's t-test for paired data and non-parametric tests were employed for statistical analysis at a 5% Level of significance.Results: Significant changes were found in forced vital. capacity, Tiffeneau index scores, maximum expiratory pressure, maximum inspiratory pressure and habits assessed in FMB with the use of RBF associated to the re-expansive patterns. No significant differences were found comparing the experimental and control groups.Conclusions: The results allow the conclusion that RBF associated to re-expansive patterns improves forced vital capacity, Tiffeneau index scores, respiratory muscle strength and habits in FMB and can therefore be used as a form of therapy for such individuals. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
INTRODUÇÃO: O grupo das doenças cardiovasculares tem sido apontado como a principal causa de óbito no Brasil desde os anos 70, sendo a hipertensão arterial sistêmica (HAS) o fator de risco mais importante para esse grupo. Entre os trabalhadores observa-se correlação negativa entre o status ocupacional e a pressão arterial. Tais fatos ressaltam a importância do conhecimento da distribuição da pressão arterial sistêmica entre os distintos grupos profissionais. Assim, foi realizado estudo para descrever o status pressórico de uma população homogênea e estável de trabalhadores do setor secundário da economia, pouco especializados e que ganham baixos salários, estabelecendo a prevalência da HAS nesse grupo específico, relacionando-a com algumas covariáveis biológicas e socioeconômicas, e comparando-a com a prevalência de HAS em outros grupos profissionais no Brasil. MÉTODO: Foram estudados 73 trabalhadores regularmente empregados em julho de 1993 em um curtume situado no Município de Botucatu, cidade de médio porte da região Centro-Oeste do Estado de São Paulo, os quais foram submetidos a exame antropométrico, aferição de pressão arterial, anamnese e exame clínico. Os resultados foram comparados com os obtidos em estudos semelhantes, controlando-se o confundimento da idade por intermédio de diferentes técnicas. RESULTADOS: A prevalência bruta da HAS encontrada foi de 56,1%, sendo 15,8% a prevalência de hipertensão sistólica isolada. Ambas se associaram ao etilismo e ao tabagismo na população estudada. DISCUSSÃO: A prevalência da hipertensão foi consideravelmente alta e significativamente maior do que a encontrada em outros grupos de trabalhadores estudados no Brasil. Tal achado ressalta a necessidade da continuidade da investigação, objetivando o isolamento dos fatores implicados na elevação pressórica do grupo estudado.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper reports the surface activity of phytase at the air-water interface, its interaction with lipid monolayers, and the construction of a new phytic acid biosensor on the basis of the Langmuir-Blodgett (LB) technique. Phytase was inserted in the subphase solution of dipalmitoylphosphatidylglycerol (DPPG) Langmuir monolayers, and its incorporation to the air-water interface was monitored with surface pressure measurements. Phytase was able to incorporate into DPPG monolayers even at high surface pressures, ca. 30 mN/m, under controlled ionic strength, pH, and temperature. Mixed Langmuir monolayers of phytase and DPPG were characterized by surface pressure-area and surface potential-area isotherms, and the presence of the enzyme provided an expansion in the monolayers ( when compared to the pure lipid at the interface). The enzyme incorporation also led to significant changes in the equilibrium surface compressibility (in-plane elasticity), especially in liquid-expanded and liquid-condensed regions. The dynamic surface elasticity for phytase-containing interfaces was investigated using harmonic oscillation and axisymmetric drop shape analysis. The insertion of the enzyme at DPPG monolayers caused an increase in the dynamic surface elasticity at 30 mN m(-1), indicating a strong interaction between the enzyme and lipid molecules at a high-surface packing. Langmuir-Blodgett (LB) films containing 35 layers of mixed phytase-DPPG were characterized by ultraviolet-visible and fluorescence spectroscopy and crystal quartz microbalance nanogravimetry. The ability in detecting phytic acid was studied with voltammetric measurements.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJECTIVES To test the hypothesis that glyco protein 91phox (gp91(phox)) subunit of nicotinamide adenine dinucleotide phosphate [NAD(P) H] oxidase is a fundamental target for physical activity to ameliorate erectile dysfunction (ED). Vascular risk factors are reported to contribute to ED. Regular physical exercise prevents cardiovascular diseases by increasing nitric oxide (NO) production and/or decreasing NO inactivation.METHODS Male Wistar rats received the NO synthesis inhibitor N(omega)-nitro-L-arginine methyl ester (L-NAME) for 4 weeks, after which animals were submitted to a run training program for another 4 weeks. Erectile functions were evaluated by in vitro cavernosal relaxations and intracavernous pressure measurements. Expressions of gp91(phox) subunit and neuronal nitric oxidase synthase in erectile tissue, as well as superoxide dismutase activity and nitrite/nitrate (NO(x)) levels were determined.RESULTS The in vitro acetylcholine-and electrical field stimulation-induced cavernosal relaxations, as well as the increases in intracavernous pressure were markedly reduced in sedentary rats treated with L-NAME. Run training significantly restored the impaired cavernosal relaxations. No alterations in the neuronal nitric oxidase synthase protein expression (and its variant penile neuronal nitric oxidase synthase) were detected. A reduction of NO(x) levels and superoxide dismutase activity was observed in L-NAME-treated animals, which was significantly reversed by physical training. Gene expression of subunit gp91(phox) was enhanced by approximately 2-fold in erectile tissue of L-NAME-treated rats, and that was restored to basal levels by run training.CONCLUSIONS Our study shows that ED seen after long-term L-NAME treatment is associated with gp91(phox) subunit upregulation and decreased NO bioavailability. Exercise training reverses the increased oxidative stress in NO-deficient rats, ameliorating the ED. UROLOGY 75: 961-967, 2010. (C) 2009 Elsevier B.V.
Resumo:
As arterial hypertension can be diagnosed by different methods, among which are the traditional auscultatory instrument and the automated oscillometric monitor, the aim of this study was to compare the performance of these instruments, to evaluate the reliability of the digital oscillometer. The sample consisted of 40 patients under dental treatment, whose blood pressure measurements were recorded. The measurements of systolic and diastolic blood pressures were evaluated in terms of their intraclass correlation coefficients (r). For systolic blood pressure, an excellent level of agreement was found between the instruments, with r=0.93, and for diastolic blood pressure, there was a good level of agreement (r=0.75). It was concluded, from the excellent agreement for systolic blood pressure, that the oscillometric monitor can be recommended for the monitoring of the variations of that pressure in the same individual, while the good agreement obtained in the determination of the diastolic blood pressure indicates that the oscillometric method is reliable. However, new studies need to be carried out for a better understanding of the disagreements that can occur in the diastolic pressure results.
Resumo:
Model: Prevalence study. Objectives: To evaluate the presence of self-reported hypertension to compare with blood pressure measurements. Besides, this work investigated health information level of workers and if the job position has any influence on blood pressure (BP). Methods: This study evaluated 349 health workers (44±10 years old) from Bauru and Jau cities, who answered some questions about history of health condition, use of medicines, past surgeries as well as social, scholar and physical conditions and had their blood pressure measured. Each subject selfreported as normotensive or hypertensive. Values of systolic ≥ 140 mmHg and/or diastolic PA ≥ 90 mmHg were considered elevated. Among the health workers evaluated, 198 were submitted to anthropometric and biochemical evaluations. Values are presented as means ± SD and frequency of distribution. It was used T-student test (p<0.05). Results: From all workers evaluated only 16% self-reported as hypertensive, which 56% presented high BP, however 91% used to take antihypertensive medicines. Among the 84% who self-reported as normotensive, 24% presented high BP and 8% used to take medicines. Although most of the employees of each section self-reported as normotensive, more than a half presented high BP and which was more common in the health's section (76.3%). Conclusion: These results suggest that besides the majority of the employees self-reported as normotensive, an elevated number of health workers presented high blood pressure and used to take medicines inappropriately, which indicates that they did not have enough knowledge about their health. Furthermore, it was observed that Health Section presented the higher blood pressure values.
Resumo:
This quasi-experimental study describes the effects of a yoga sequence following hemodynamic and biochemical parameters in patients with hypertension. Thirty-three volunteers participated in the study (control = 16 and yoga = 17) for four months. Blood pressure measurements, cardiac and respiratory rate were collected monthly, while the biochemical profile was taken at the beginning and end of the program. To analyze the data, Student's t test and repeated measures analyses were performed. The yoga group showed a significant reduction of systolic blood pressure, heart and respiratory rate (p < 0.05). As for the biochemical profile, the yoga group showed correlation coefficients between initial values and final responses greater than the control of fasting glucose, total cholesterol, LDL-cholesterol and triglycerides. The elaborated sequence practice promoted significant cardiovascular and metabolic benefits. The yoga exercises performed in the proposed sequence constitute complementary non-pharmacological control of blood pressure in patients with hypertension. © 2012 Elsevier Ltd.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The practice of regular physical activity has been considered a protective factor against the degenerative processes of the body, acting as a promoter of health, especially for risk groups such as obese and resistant groups exercise adherence as among the intellectually disabled (ID) . This study involved the administration of a training protocol and the physical parameters of longitudinal health in a subject about 43 years, intellectually deficient, hypertensive, obese and with a strong predisposition to develop diabetes and heart disease. The main objective of long-term program was to reduce body weight and normalize blood pressure (BP) after the student's physical activity and preferentially interfere with BP values at rest (ie before the daily schedule). The other objective was to improve general physical fitness. The protocol involved four meetings per week lasting one hour, in addition to participation in the program PROEFA (twice a week with sessions of one hour each), totaling 57 sessions spread over five months. The evaluation protocol included in each session the following tests: blood pressure measurements and heart rate, and amount of physical activity recorded via pedometer. Tests applied before and after the training included: anthropometric assessment, agility test, flexibility test, test drive through vertical and horizontal jumps and endurance to the test bench. The mass (kg) and BMI corresponded to the initial values of 127.7 kg and 42.05 kg m-2, and 5 months after 113.2 kg and 37.48 kg m-2, respectively. The waist-hip ratio was close to 1 after the intervention and this value corresponded to 0.98. For the test of agility (shuttle run) was not found improvement in performance. To test the values of the horizontal jump in pre-test were 52 cm and 56 cm post-test, vertical jump has been improved and...(Complete abstract click electronic access below)
Resumo:
We report on the realization of a capacitive dilatometer, designed for high-resolution measurements of length changes of a material for temperatures 1.4K ≤ T ≤ 300K and hydrostatic pressure P ≤ 250MPa. Helium ( 4He) is used as a pressure-transmitting medium, ensuring hydrostatic-pressure conditions. Special emphasis has been given to guarantee, to a good approximation, constant-pressure conditions during temperature sweeps. The performance of the dilatometer is demonstrated by measurements of the coefficient of thermal expansion at pressures P ≃ 0.1MPa (ambient pressure) and 104MPa on a single crystal of azurite, Cu 3(CO 3) 2(OH) 2, a quasi-one-dimensional spin S = 1/2 Heisenberg antiferromagnet. The results indicate a strong effect of pressure on the magnetic interactions in this system. © 2012 American Institute of Physics.
Resumo:
The influence of 2 different levels of the inspired oxygen fraction (FiO(2)) on blood gas variables was evaluated in dogs with high intracranial pressure (ICP) during propofol anesthesia (induction followed by a continuous rate infusion [CRI] of 0.6 mg/kg/min) and intermittent positive pressure ventilation (IPPV). Eight adult mongrel dogs were anesthetized on 2 occasions, 21 d apart, and received oxygen at an FiO(2) of 1.0 (G100) or 0.6 (G60) in a randomized crossover fashion. A fiberoptic catheter was implanted on the surface of the right cerebral cortex for assessment of the ICP. An increase in the ICP was induced by temporary ligation of the jugular vein 50 min after induction of anesthesia and immediately after baseline measurement of the ICP. Blood gas measurements were taken 20 min later and then at 15-min intervals for 1 h. Numerical data were submitted to Morrison's multivariate statistical methods. The ICP, the cerebral perfusion pressure and the mean arterial pressure did not differ significantly between FiO(2) levels or measurement times after jugular ligation. The only blood gas values that differed significantly (P < 0.05) were the arterial oxygen partial pressure, which was greater with G100 than with G60 throughout the procedure, and the venous haemoglobin saturation, that was greater with G100 than with G60 at M0. There were no significant differences between FiO(2) levels or measurement times in the following blood gas variables: arterial carbon dioxide partial pressure, arterial hemoglobin saturation, base deficit, bicarbonate concentration, pH, venous oxygen partial pressure, venous carbon dioxide partial pressure and the arterial-to-end-tidal carbon dioxide difference.