8 resultados para Dynamic Conditional Correlation

em Reposit


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dynamic viscosity of binary mixtures of poly(ethylene glycol) molar mass 1500 da + water, potassium phosphate + water, and ternary mixtures of poly(ethylene glycol) molar mass 1500 da + potassium phosphate + water were determined at 303.15 K Binary and ternary mixture viscosities showed a direct logarithm-type relation with the increase of poly(ethylene glycol) and potassium phosphate contents. The models used for viscosity correlation gave a good fit to the experimental data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dynamic light scattering measurements have been made to elucidate changes in the coil conformation of a high molecular weight poly(ethylene oxide) (PEG) fraction when the non-ionic surfactant C(12)E(5) is present in dilute solutions. The measurements were made at 20 degrees C as functions of(a) the C(12)E(5) concentration at constant PEO concentration, (b) the PEO concentration at constant C(12)E(5) concentration, and (c) the C(12)E(5)/PEO concentration ratio. The influence of temperature on the interactions in terms of the relaxation time distributions was also examined up to the cloud point. It was found that when the C(12)E(5)/PEO weight ratio was >2 and when the temperature was >14 degrees C, the correlation functions became bimodal with well-separated components. The fast mode derives fi om individual surfactant micelles which are present in the solution at high number density. The appearance of the slow mode, which dominates the scattering, is interpreted as resulting from the formation of micellar clusters due to an excluded-volume effect when the high molar mass (M = 6 x 10(5)) PEO is added to the surfactant solution. It is shown that the micellar clusters form within the PEO coils and lead to a progressive swelling of the latter for steric reasons. The dimensions of the PEO/C(12)E(5) complex increase with increasing surfactant concentration to a value of R(H) approximate to 94 nm (R(g) approximate to 208 nm) at C-C12E5 = 3.5%. Fluorescence quenching measurements show that the average aggregation number of C(12)E(5) increases significantly on addition of the high molar mass PEG. With increasing temperature toward the cloud point the clusters increase in number density and/or become larger. The cloud point is substantially lower than that for C12E5 in water solution and is strongly dependent on the PEO concentration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the relationship between carotenoid concentrations in serum and breast tissue, we measured serum carotenoid concentrations and endogenous carotenoid levels in breast adipose tissue of women with benign breast tumor (n = 46) or breast cancer (n = 44). Before extraction, serum was digested with lipase and cholesterol esterase, and breast adipose tissue was saponified. Serum and tissue carotenoids were extracted with ether/hexane and measured by using HPLC with a C30 column. Serum retinoic acid was extracted with chloroform/methanol and measured using HPLC with a C18 column. There were no significant differences in serum carotenoids [lutein, zeaxanthin, cryptoxanthin (both α- and β-), α-carotene, all-trans β-carotene, 13-cis β-carotene and lycopene], retinoids (retinol, all-trans and 13-cis retinoic acids), and α- and -γ- tocopherol concentrations between benign breast tumor patients and breast cancer patients. A substantial amount of 9-cis β- carotene was present in adipose tissue and was the only carotenoid that had a significantly lower level in benign breast tumor patients than in breast cancer patients. Correlations between carotenoid concentrations in serum and in breast adipose tissue were determined by combining the data of the two groups. Concentrations of the major serum carotenoids except cryptoxanthin showed significant correlations with breast adipose tissue carotenoid levels. When the concentrations of serum carotenoids were adjusted for serum triglycerides or LDL, correlations between serum carotenoid concentrations and breast adipose tissue carotenoid levels markedly increased, including that of cryptoxanthin (P <0.001). The strong correlation between serum carotenoid concentrations and endogenous breast adipose tissue carotenoid levels indicate that dietary intake influences adipose tissue carotenoid levels as well as serum concentrations, and that adipose tissue is a dynamic reservoir of fat-soluble nutrients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Matematica Aplicada e Computacional - FCT

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Excessive rearfoot eversion is thought to be a risk factor for patellofemoral pain development, due to the kinesiological relationship with ascendant adaptations. Individuals with patellofemoral pain are often diagnosed through static clinical tests, in scientific studies and clinical practice. However, the adaptations seem to appear in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Thus, the aim of this study was to determine the reliability and differentiation capability of three rearfoot eversion measures: rearfoot range of motion, static clinical test and static measurement using a three-dimensional system. A total of 29 individuals with patellofemoral pain and 25 control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional motion analysis during stair climbing and static clinical tests. Intraclass correlation coefficient and standard error measurements were performed to verify the reliability of the variables and receiver operating characteristic curves to show the diagnostic accuracy of each variable. In addition, analyses of variance were performed to identify differences between groups. Rearfoot range of motion demonstrated higher diagnostic accuracy (an area under the curve score of 0.72) than static measures and was able to differentiate the groups. Only the static clinical test presented poor and moderate reliability. Other variables presented high to very high values. Rearfoot range of motion was the variable that presented the best results in terms of reliability and differentiation capability. Static variables do not seem to be related to patellofemoral pain and have low accuracy values.