86 resultados para Body Approximation Methods

em Reposit


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Doppler ultrasonography is an important tool for evaluating hepatic portal hemodynamics. However, no study in dogs of different body weights, in the range encountered in routine clinical veterinary practice, has been reported. It can be difficult to obtain an ideal insonation angle when evaluating the main portal vein, so evaluation of the right portal vein branch has been described in humans as an alternative. The aim of this study was to analyze, through Doppler ultrasonography, the hemodynamics in the right portal vein branch in dogs of different body weights.Methods: Thirty normal dogs were divided in three groups by weight, in order to establish normal values for mean velocity, flow volume and portal congestion index of the right portal vein branch by means of Doppler ultrasonography.Results: In all dogs ideal insonation angles were obtained for the right portal vein branch. The average velocity was similar in the three groups, but the portal congestion index and the flow volume differed, showing that the weight of the dog can influence these values.Conclusion: Doppler ultrasonography for the evaluation of flow in the right branch of the portal vein could be a viable alternative, or complement, to examining the main vessel segment. This is especially so in those animals in which an ideal insonation angle for examination of the main portal vein is hard to obtain. In addition, the weight of the dog must be considered for the correct evaluation of the portal system hemodynamics, particularly for portal blood flow and the congestion index.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Loss of muscle strength may represent a burden on everyday tasks significantly compromising the quality of life for mastectomy patients. In addition to the reduced strength of the upper limb, has been shown in mastectomy patients and difficulties in reducing grip. Objectives: To analyze the possible differences in grip strength among women undergoing breast cancer surgery and to compare the body composition. Methods: In the control group (CG n = 46) women participated in the community of FCT / UNESP aged 35 to 70 years without acute orthopedic pathologies. In the experimental group (EG n = 49) participated in women undergoing surgery for breast cancer, without bilateral lymphedema and independent of time and type of surgery. Were evaluated by dynamometer, by Dual Energy X-ray absorptiometry (DEXA) and physical assessment. Results: We observed significant differences in grip strength (p = 0.000), when the group after mastectomy compared with the control group and the radical mastectomy surgery left and quandrandectomia left (p = 0.004). Regarding the presence of lymphedema, statistical difference was observed in the composition of lean mass and trunk fat (p = 0.05). Conclusion: The results of this study suggest that the experimental group are lower grip strength and trunk lean body mass when compared with the control group. The experimental group showed higher values of fat mass when there was presence of lymphedema

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Many-body systems of composite hadrons are characterized by processes that involve the simultaneous presence of hadrons and their constituents. We briefly review several methods that have been devised to study such systems and present a novel method that is based on the ideas of mapping between physical and ideal Fock spaces. The method, known as the Fock-Tani representation, was invented years ago in the context of atomic physics problems and was recently extended to hadronic physics. Starting with the Fock-space representation of single-hadron states, a change of representation is implemented by a unitary transformation such that composites are redescribed by elementary Bose and Fermi field operators in an extended Fock space. When the unitary transformation is applied to the microscopic quark Hamiltonian, effective, Hermitian Hamiltonians with a clear physical interpretation are obtained. The use of the method in connection with the linked-cluster formalism to describe short-range correlations and quark deconfinement effects in nuclear matter is discussed. As an application of the method, an effective nucleon-nucleon interaction is derived from a constituent quark model and used to obtain the equation of state of nuclear matter in the Hartree-Fock approximation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The unitary pole approximation is used to construct a separable representation for a potential U which consists of a Coulomb repulsion plus an attractive potential of the Yamaguchi type. The exact bound-state wave function is employed. U is chosen as the potential which binds the proton in the 1d5/2 single-particle orbit in F-17. Using the separable representation derived for U, and assuming a separable Yamaguchi potential to describe the 1d5/2 neutron in O-17, the energies and wave functions of the ground state (1+) and the lowest 0+ state of F-18 are calculated in the Gore-plus-two-nucleons model solving the Faddeev equations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Artificial Neural Networks are widely used in various applications in engineering, as such solutions of nonlinear problems. The implementation of this technique in reconfigurable devices is a great challenge to researchers by several factors, such as floating point precision, nonlinear activation function, performance and area used in FPGA. The contribution of this work is the approximation of a nonlinear function used in ANN, the popular hyperbolic tangent activation function. The system architecture is composed of several scenarios that provide a tradeoff of performance, precision and area used in FPGA. The results are compared in different scenarios and with current literature on error analysis, area and system performance. © 2013 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this paper was to evaluate the agreement among different methods used to estimate angular deviation of the body to determine the risk for development of upper limb musculoskeletal disorders in dentistry undergraduates. Materials and Methods: Students (n = 79) enrolled in the final year undergraduate course of the Araraquara School of Dentistry-Sγo Paulo State University-UNESP were evaluated. Photographs were taken of students performing clinical procedures. The work postures adopted by each student were evaluated by means of rapid upper limb assessment (RULA). The basis used to obtain the individual's final risk score is the measurement of the angular deviations in the neutral positions of the regions evaluated. Two methods were used to estimate the angular deviation of the body: Visual exam and Image Tool software. A RULA final risk score was attributed to each procedure the student performed (n = 333). Study of the agreement between the methods about risk of musculoskeletal disorders was conducted by means of Kappa (κ) statistics. The level of significance adopted was 5%. Results: Fair agreement (κ = 0.32) between the evaluated methods was verified. Conclusion: The risk for development of upper limb musculoskeletal disorders by dentistry undergraduates evaluated by using RULA was not in agreement with the results obtained by use of visual exam and Image Tool.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this paper was to evaluate the agreement among different methods used to estimate angular deviation of the body to determine the risk for development of upper limb musculoskeletal disorders in dentistry undergraduates. Materials and Methods: Students (n = 79) enrolled in the final year undergraduate course of the Araraquara School of Dentistry-Sγo Paulo State University-UNESP were evaluated. Photographs were taken of students performing clinical procedures. The work postures adopted by each student were evaluated by means of rapid upper limb assessment (RULA). The basis used to obtain the individual's final risk score is the measurement of the angular deviations in the neutral positions of the regions evaluated. Two methods were used to estimate the angular deviation of the body: Visual exam and Image Tool software. A RULA final risk score was attributed to each procedure the student performed (n = 333). Study of the agreement between the methods about risk of musculoskeletal disorders was conducted by means of Kappa (κ) statistics. The level of significance adopted was 5%. Results: Fair agreement (κ = 0.32) between the evaluated methods was verified. Conclusion: The risk for development of upper limb musculoskeletal disorders by dentistry undergraduates evaluated by using RULA was not in agreement with the results obtained by use of visual exam and Image Tool.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objetivou-se com este trabalho avaliar o método de pendura da carcaça quanto à qualidade da carne ovina. Foram utilizadas 10 ovelhas de descarte com aproximadamente 62 kg de peso corporal. Após abate, esfola, evisceração e retirada da cabeça e das patas, as carcaças foram divididas longitudinalmente em duas partes. Lados alternados das meias carcaças foram pendurados pelo tendão do gastrocnêmico, tratamento 1 (T1) e suspensos pelo osso pélvico (T2) por um período de 24 horas em câmara frigorífica. Posteriormente retirou-se o músculo Semimembranosus de todas as meias carcaças para as análises de qualidade da carne. Os músculos Semimembranosus das carcaças pendurados pelo método de suspensão da pelve apresentou maior maciez que os mesmos músculos das carcaças pendurados pelo tendão do gastrocnêmico, com valores de 1,99 kgf.cm-2 e 3,15 kgf.cm-2, respectivamente. O tratamento 2 obteve menores perdas por cocção da carne que o tratamento 1, com valores médios de 32,14 e 33,44%, respectivamente. Os demais parâmetros de qualidade de carne avaliados não foram influenciados pelo método de suspensão da carcaça. Concluiu-se que o método de suspensão da carcaça, influenciou a maciez e as perdas por cocção da carne, sendo os melhores resultados para as carcaças penduras pelo osso pélvico.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)