64 resultados para wearing
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
The incidence of temporomandibular disorder signs and symptoms in patients wearing complete dentures
Resumo:
Bruxism is widely defined as an anxiety response to environmental stress. Occlusal splints are frequently used in sleep bruxism, to protect teeth from damage resulting from the contraction force of mandibular muscles, or to reduce the orofacial pain by relaxing masticatory muscles. Surface electromyography (EMG) of the right and left masseter and temporalis muscles was performed in 15 women presenting sleep bruxism and temporomandibular disorders related to occupational stress, after nocturnal use of the occlusal splint. The EMG signals were recorded twice per patient: After a work shift (pre-splint) and after a night of sleep with the occlusal splint (post-splint) before a new workday. The parametric t-paired test was used to compare differences of the RMS amplitude between pre and post-splint records, for resting and maximal clenching effort. The level of significance for each comparison was set to p < 0.05. The results of the study supports the premise that the use of occlusal splint reduces EMG activity in the masseter and anterior temporalis muscles, in patients who presented with sleep bruxism related to occupational stress. © 2011 Elsevier Ltd.
Resumo:
Objective: The prevalence of wearing and fracture of complete dentures was evaluated among edentulous patients treated in two dental schools in Brazil. Background: Acceptance and wearing of complete dentures are related to adaptive behaviour of edentulous patients. However, one reason that could interfere with the wearing dentures is their potential to fracture, which is still a common complication in denture rehabilitation practice. Material and methods: Two hundred and twenty-four edentulous patients rehabilitated with complete dentures from 2000 to 2005 in Araçatuba and Araraquara Dental School, University of State of São Paulo, were assessed in 2006 and 2007 to answer a questionnaire about wearing and fracture of their dentures. Statistical analysis were performed using Epi Info software and chi-squared test to compare maxillary and mandibular data (α = 0.05). Results: Almost 26% of the patients did not wear their dentures, and among the remainder, the majority wore the maxillary denture. About 30% of the dentures were fractured, with higher prevalence in the maxillary arch (p = 0.003). Conclusions: Discontinuation of wearing dentures was quite high, especially considering the treatment which was carried out in university clinics. Prevalence of fractures was also high, greater for the maxillary denture, and was one of the main reasons for non-wearing of complete dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to assess the improvement in psychosocial awareness of anophthalmic patients wearing ocular prostheses and its relationship with demographic characteristics, factors of loss/treatment, social activity, and relationship between professional and patient. Surveys including a form for evaluation of psychosocial pattern were conducted with 40 anophthalmic patients rehabilitated with ocular prosthesis at the Center of Oral Oncology in the authors' dental school from January 1998 to November 2010. The improvement in psychosocial awareness was assessed by comparing the perception of some feelings reported in the period of eye loss and currently. Wilcoxon tests were applied for comparison of patients' perception between the periods. χ2 tests were used to assess the relationship between the improvement in psychosocial awareness and the variables of the study. In addition, the logistic regression model measured this relationship with the measure of odds ratio. The feelings of shame, shyness, preoccupation with hiding it, sadness, insecurity and fear were significant for improvement in psychosocial awareness. It was concluded that the anophthalmic patients wearing an ocular prosthesis has significant improvement in psychosocial awareness after rehabilitation. © 2012 International Association of Oral and Maxillofacial Surgeons.
Resumo:
ObjectivesThe aim of this study was to evaluate the quality of life and satisfaction of patients wearing implant-supported fixed partial dentures.Materials &methodsA total of 106 patients were selected and submitted to clinical examination and collection of the demographic data for evaluation of the implant-supported fixed dentures conditions. All participants agreed to answer to the Oral Health Impact Profile (OHIP-EDENT) questionnaire and another questionnaire about satisfaction with the implant-supported prostheses. The patients were classified into the following three groups for statistical analysis: patients wearing splinted implant-supported prosthesis (E), patients wearing single implant-supported prosthesis (U), and patients wearing single implant-supported prosthesis associated with splinted prosthesis (E+U). Kruskal-Wallis test was used to compare the answers between the groups, and a logistic regression model was measured to verify the relation between variables of the patients and the questionaries'items.ResultsThere were significant differences among groups (P=0.006) for discomfort during surgery itself of the satisfaction questionnaire. The marital status, groups, and hygiene condition were significant mainly for physical pain item.ConclusionsIt was concluded that the patients presented high level of satisfaction and quality of life for the most of the items evaluated as well as the groups showed similar results.
Resumo:
The aim of this study was to investigate oral yeast colonization, antifungal susceptibility and strain diversity in insulin-dependent diabetes mellitus patients (175), as well as to evaluate the influence of dental prostheses. Oral rinse samples were cultured on selective media, in order to isolate, count and identify the yeasts recovered. More than half of the diabetic subjects (53%) carried significant amounts of Candida cells in the buccal cavity and these organisms were recovered at higher densities in diabetics wearing dentures. A total of 93 yeast strains were isolated from these patients, including: Candida spp. (n = 89); Pichia (n = 02); Trichosporon (n = 1), and Geotrichum (n = 1). C. albicans represented 56% of these strains, non-albicans Candida 39.8%, and other genera of yeast 4.3%. C. albicans was prevalent, followed by C. parapsilosis, C. tropicalis, C. glabrata, C. krusei, C. rugosa and C. guilliermondii. Agar disk-diffusion tests of the susceptibility of non-albicans Candida and other genera of yeast to fluconazole showed resistance in 21.9%, mainly in C. rugosa (100%), C. glabrata (57%) and C. krusei (50%). Local oral factors, such as the presence of dentures, in association with diabetes, seemed to have the effect of increasing the amount and variety of Candida species in the oral cavities, mainly those with lower drug susceptibilities.
Resumo:
The use of the SenseWear (TM) armband (SWA), an objective monitor of physical activity, is a relatively new device used by researchers to measure energy expenditure. These monitors are practical, relatively inexpensive and easy-to-use. The aim of the present study was to assess the validity of SWAs for the measurement of energy expenditure (EE) in circuit resistance training (CRT) at three different intensities in moderately active, healthy subjects. The study subjects (17 females, 12 males) undertook CRT at 30, 50 and 70% of the 15 repetition maximum for each exercise component wearing an SWA as well as an Oxycon Mobile (OM) portable metabolic system (a gold standard method for measuring EE). The EE rose as exercise intensity increased, but was underestimated by the SWAs. For women, Bland-Altman plots showed a bias of 1.13 +/- A 1.48 METs and 32.1 +/- A 34.0 kcal in favour of the OM system, while for men values of 2.33 +/- A 1.82 METs and 75.8 +/- A 50.8 kcal were recorded.
Resumo:
Considering the constant technological developments in the aeronautical, space, automotive, shipbuilding, nuclear and petrochemical fields, among others, the use of materials with high strength mechanical capabilities at high temperatures has been increasingly used. Among the materials that meet the mechanical strength and corrosion properties at temperatures around 815 degrees C one can find the nickel base alloy Pyromet 31V (SAE HEV8). This alloy is commonly applied in the manufacturing of high power diesel engines exhaust valves where it is required high resistance to sulphide, corrosion and good resistance to creep. However, due to its high mechanical strength and low thermal conductivity its machinability is made difficult, creating major challenges in the analysis of the best combinations among machining parameters and cutting tools to be used. Its low thermal conductivity results in a concentration of heat at high temperatures in the interfaces of workpiece-tool and tool-chip, consequently accelerating the tools wearing and increasing production costs. This work aimed to study the machinability, using the carbide coated and uncoated tools, of the hot-rolled Pyromet 31V alloy with hardness between 41.5 and 42.5 HRC. The nickel base alloy used consists essentially of the following components: 56.5% Ni, 22.5% Cr, 2,2% Ti, 0,04% C, 1,2% Al, 0.85% Nb and the rest of iron. Through the turning of this alloy we able to analyze the working mechanisms of wear on tools and evaluate the roughness provided on the cutting parameters used. The tests were performed on a CNC lathe machine using the coated carbide tool TNMG 160408-23 Class 1005 (ISO S15) and uncoated tools TNMG 160408-23 Class H13A (ISO S15). Cutting fluid was used so abundantly and cutting speeds were fixed in 75 and 90 m/min. to feed rates that ranged from 0.12, 0.15, 0.18 and 0.21 mm/rev, and cutting depth of 0.8mm. The results of the comparison between uncoated tools and coated ones presented a machined length of just 30% to the first in relation to the performance of the second. The coated tools has obtained its best result for both 75 and 90 m/min. with feed rate of 0.15 mm/rev, unlike the uncoated tool which obtained its better results to 0.12 mm/rev.
Resumo:
Background: The record of electrical activity of elevator muscles in mandible is important for the evaluation of muscular potency and diagnosis of neuromuscular pathologies, which allows prevention and treatment. The aim of this study was to define silent periods (SPs) and the importance in dentistry and compare the SPs in masticatory muscles of dentate and edentulous patients wearing prosthesis considering the presence or absence of craniomandibular dysfunction (CMD).Materials and Methods: Literature review in PubMed database.Discussion: Silent periods are isolated pulses of transcranial magnetic stimulation in the primary motor cortex during voluntary muscular activity that generates an interruption of muscular activity for hundredths of milliseconds. The SP duration depends on the patient (dentate or edentulous), type of stimulus, and presence of CMD.Conclusions: The SP is higher in complete edentulous patients and in individuals with occlusal disharmonies than in dentate patients without CMDs. The treatment of CMDs through occlusal therapy decreases SP duration.
Resumo:
The aim of this study was to assess the electrical activity of the masseter and anterior temporal muscles in subjects with severe bone resorption at two different times: ( a) the initial period, with the complete dentures they had worn for over 10 years, and (b) the final period, 5 months after having new dentures put into place. Twelve asymptomatic subjects were asked to respond to the questionnaire, according to the research diagnostic criteria for temporomandibular disorders, before denture rehabilitation and 5 months after the new dentures were put in place. The electrical activity of the muscles was recorded during mastication in the initial and final period, using artificial food (Optocal). The operator monitored the 35 chewing cycles that were repeated to grind the artificial food. After wearing the new dentures for 5 months, the right anterior temporal muscle showed a statistical difference before and after denture rehabilitation at the beginning and end of mastication. Muscular capacity and ability reduced the electrical activity in the masseter muscles after rehabilitation. Copyright (c) 2008 S. Karger AG, Basel.
Resumo:
Purpose: The aim of this study was to assess the presence of temporomandibular joint (TMJ) noises in subjects with severe bone resorption, who have worn the same complete dentures for over 10 years, and 5 months after treatment with increments of acrylic resin on the occlusal surface after having new dentures in place.Methods: After applying the research diagnostic criteria (RDC)/temporomandibular disorder (TMD) questionnaire, 20 asymptomatic subjects were assessed before and 5 months after the new dentures were put in place. Joint vibrations were assessed by the Sono Pak program by selecting the vibrations that occurred during the opening and closing cycle.Results: The means of the results revealed a nonnormal distribution and were submitted to Kruskal-Wallis statistical analysis (p < 0.05). The vibration means were of low intensity (<= 9.96 Hz). After rehabilitation, there was a reduction in the vibrations (<= 5.2 Hz) statistically significant only at the end of mouth opening with the old dentures when compared with the other cycles.Conclusion: The intensity and number of occurrences of joint vibrations were reduced after 5 months of wearing new dentures.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)