41 resultados para water monitoring

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Human population growth and increased industrial activity in recent decades have contributed to a range of environmental problems, including the contamination of groundwater and surface water. In order to help in the management of these resources, water quality indices are used as tools to summarize multiple parameters and express them in the form of a single number. The ability to provide both an integrated assessment of changes in environmental variables, as well as performance tracking, has resulted in such indices being increasingly employed in surface water monitoring programs. The aim of this study was to develop an Index for Public Supply Water Quality (IPS) using a fuzzy inference methodology. Linguistic systems generally provide satisfactory tools for qualitative purposes, enabling the inclusion of descriptive variables with reduced loss of individual information. Validation of the technique was achieved by analysis of measurement data obtained for the Sorocaba River, provided by CETESB. The new procedure proved more rigorous, compared to classical IPS. It could be readily applied in the evaluation of other water bodies, or be adjusted to incorporate additional parameters also considered important for the assessment of water quality.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We compared the fish assemblage structure from streams with different intensities of physical habitat degradation and chemical water pollution by domestic sewage in southeastern Brazil. Eight streams (R1-R8) showing less disturbed or more disturbed conditions of chemical water quality and of physical habitat quality were selected. Cumulative abundance and biomass, combined in ABC plots, revealed (i) biomass curves above the abundance curves, represented by the streams R1-R2 (water and habitat less disturbed) and R5-R6 (water more disturbed and habitat less disturbed), and (ii) biomass curves below the abundance curves, represented by the streams R3-R4 (water less disturbed and habitat more disturbed) and R7-R8 (water and habitat more disturbed). The quantitative structure of the ichthyofauna showed significant correspondence with physical habitat condition but not with chemical water quality. The most significant species to cause the dissimilarity between less disturbed and more disturbed physical habitats was the exotic Poecilia reticulata. Such results indicate that in the focused region-with little influence of industrial pollution, noncritical domestic sewage discharge, and soil predominantly used for pasture-streams with high physical habitat integrity possess a differently structured ichthyofauna than streams with relatively low physical habitat integrity, reinforcing the importance of the physical habitat quality and riparian conservation along these water courses, warranting the conservation of these systems. Indeed, our results also reinforce the importance of including biotic descriptors, particularly of the ichthyo-fauna, in water-monitoring programs designed to reveal signs of human interference.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In areas where human activities, as agriculture, are developed land use contributes to physical, chemical and biological characteristics of water. This study aimed to identify physical and chemical variations of the water monitoring network in 4 first magnitude watersheds with different land use/occupation in the hydrographic basin of the Glori Farm Creek in the city of Taquaritinga, State of Sao Paulo, from February to July, 2005. The methodology consisted of weekly sample water collections to naalyze turbidity, temperature, dissolved oxygen, pH and electric conductivity. The characterization of the hydrological conditions of the watersheds showed that agricultural activities, including the productive system of the sugarcane cultivation, have affected the quality of water resources.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O manejo de irrigação pode influenciar o comportamento ecofisiológico e a produção da videira. O objetivo desse trabalho, conduzido em 2010 em Petrolina – PE, no Submédio do Vale do São Francisco, foi avaliar a influência de diferentes estratégias de manejo de irrigação no potencial de água na folha e em aspectos qualitativos e quantitativos das uvas do primeiro ciclo de produção da videira cv. Syrah/Paulsen 1103. O sistema de irrigação utilizado foi gotejamento e a lâmina de água foi estimada com base na evapotranspiração da cultura. O delineamento experimental utilizado foi o de blocos casualizados, em 4 repetições e com 3 tratamentos: irrigação plena, realizada durante todo o ciclo de produção; a irrigação com déficit, onde a aplicação de água foi interrompida na fase fenológica de cacho fechado; e a irrigação com déficit controlado, onde a irrigação, também interrompida na fase de cacho fechado, foi eventualmente realizada após a interrupção, de acordo com o monitoramento da água no solo. A imposição de déficit hídrico às plantas favoreceu uma maior concentração de açúcares e a redução da acidez nos frutos, contribuindo para a melhoria da qualidade das uvas para vinificação.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Presented here is a study about the capability of a sensing unit to detect changes in river water quality. In order to determine its accuracy, water quality was monitored at 11 points along the Veado River in Presidente Prudente, Brazil. To have a basis for comparison, a water quality index (WQI) was developed following methods previously applied in different watersheds. Results showed an accurate relationship between WQI and electric impedance readings detected by the sensing unit. Principal components analysis (PCA) was used to derive results in a form that can be correlated with WQI calculated for each sample point, which showed the potential application of this device.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Trying to reduce particle contamination in lubrication systems, industries of the whole world spend millions of dollars each year on the improvement of filtration technology. In this context, by controlling fluid cleanliness, some companies are able to reduce failures rates up to 85 percent. However, in some industries and environments, water is a contaminant more frequently encountered than solid particles, and it is often seen as the primary cause of component failure. Only one percent of water in oil is enough to reduce life expectancy of a journal bearing by 80 percent. For rolling bearing elements, the situation is worse because water destroys the oil film and, under the extreme temperatures and pressures generated in the load zone of a rolling bearing element, free and emulsified water can result in instantaneous flash-vaporization giving origin to erosive wear. This work studies the effect of water as lubricant contaminant in ball bearings, which simulates a situation that could actually occur in real systems. In a designed bench test, three basic lubricants of different viscosities were contaminated with different contents of water. The results regarding oil and vibration analysis are presented for different bearing speeds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Humoral immune response of water buffalo naturally infected with Toxocara vitulorum was monitored using three different antigens of this parasite in serum and colostrum of buffalo cows and calves. Soluble extract (Ex) and excretory/secretory (ES) larval antigens and perienteric fluid antigen (Pe) of adult T vitulorum were used to measure the antibody levels by an indirect ELISA. Serum of 7-12 buffalo cows for the first 365 days and colostrum of the same number of buffalo cows for the first 60 days of parturition, and serum of 8-10 buffalo calves for the first 365 days afterbirth were assayed. The ELISA detected antibodies against all three T vitulorum antigens in the colostrum and serum of 100% of buffalo cows and calves examined. The highest antibody levels against Ex, ES and Pe antigens were detected in the buffalo cow sera during the perinatal period and were maintained at high levels through 300 days after parturition. on the other hand, colostrum antibody concentrations of all three antigens were highest on the first day post-parturition, but decreased sharply during the first 15 days. Concomitantly to the monitoring of immune response, the parasitic status of the calves was also evaluated. In calves, antibodies passively acquired were at the highest concentrations 24 h after birth and remained at high levels until 45 days coincidentally with the peak of T vitulorum infection. The rejection of the worms by the calves occurred simultaneously with the decline of antibody levels, which reached their lowest levels between 76 and 150 days. Thereafter, probably because of the presence of adults/larvae stimulation, the calves acquired active immunity and the antibodies started to increase slightly in the serum and plateaued between the days 211 and 365. All three antigens were detected by the serum antibodies of buffalo calves; however, the concentration of anti-Pe antibody was higher than anti-EX and anti-ES, particularly after 90 days of age. By conclusion, the buffalo cows develop immunity and keep high levels of antibodies against T vitulorum-Ex, ES and Pe antigens and these antibodies are transferred to their calves through the colostrum. This passively acquired immunity does not protect the calves against the acquisition of the infection, but these antibodies, passively or actively acquired, may have an important role during worm rejection by the calves and prevention of intestinal reinfection. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: The aim of this study was to identify and determine the diversity, occurrence and distribution of fungi in water used at a haemodialysis centre.Methods and Results: Samples in the hydraulic circuit for the distribution of the water, dialysate samples and samples of sterilization solution from dialysers were collected over a 3-month period, and 500 ml of each sample was filtered through membranes. All together 116 isolates of fungi were recovered from 89% of all water samples collected inside the haemodialysis unit, with prevalence of moulds in tap water samples and of yeasts in dialysate samples. Fusarium spp. was the most abundant genus found, whereas Candida parapsilosis was the predominant yeast species.Conclusions: This study demonstrated that various fungi were present in the water system. These data suggest the inclusion of the detection and quantification of fungi in the water of haemodialysis.Significance and Impact of the Study: The recovery of fungi from aqueous haemodialysis environments implies a potential risk for haemodialysis patients and indicates the need for continuous maintenance and monitoring. Further studies on fungi in haemodialysis water systems are required to investigate the organism ability to persist, their role in biofilm formation and their clinical significance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The microbiological monitoring of the water used for hemodialysis is extremely important, especially because of the debilitated immune system of patients suffering from chronic renal insufficiency. To investigate the occurrence and species diversity of bacteria in waters, water samples were collected monthly from a hemodialysis center in upstate São Paulo and tap water samples at the terminal sites of the distribution system was sampled repeatedly (22 times) at each of five points in the distribution system; a further 36 samples were taken from cannulae in 19 hemodialysis machines that were ready for the next patient, four samples from the reuse system and 13 from the water storage system. To identify bacteria, samples were filtered through 0.22 mu m-pore membranes; for mycobacteria, 0.45 mu m pores were used. Conventional microbiological and molecular methods were used in the analysis. Bacteria were isolated from the distribution system (128 isolates), kidney machine water (43) and reuse system (3). Among these isolates, 32 were Gram-positive rods, 120 Gram-negative rods, 20 Gram-positive cocci and 11 mycobacteria. We propose the continual monitoring of the water supplies in hemodialysis centers and the adoption of effective prophylactic measures that minimize the exposure of these immunodeficient patients to contaminated sources of water.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since 2004, Brazil has been the leading exporter of chicken. Because of the importance of this sector in the Brazilian economy, food safety must be ensured by control and monitoring of the production stages susceptible to contamination, such as the chilling process. The goal of this study was to evaluate changes in microbial levels on chicken carcasses and in chilling water after immersion in a chilling system for 8 and 16 h during commercial processing. An objective of the study was to encourage discussion regarding the Brazilian Ministry of Agriculture Livestock and Food Supply regulation that requires chicken processors to completely empty, clean, and disinfect each tank of the chilling system after every 8-h shift. Before and after immersion carcasses were collected and analyzed for mesophilic bacteria, Enterobacteriaceae, conforms, and Escherichia coli. Samples of water from the chilling system were also analyzed for residual free chlorine. The results do not support required emptying of the chiller tank after 8 h; these tanks could be emptied after 16 h. The results for all carcasses tested at the 8- and 16-h time points indicated no significant differences in the microbiological indicators evaluated. These data provide both technical and scientific support for discussing changes in federal law regarding the management of immersion chilling water systems used as part of the poultry processing line.