59 resultados para urine reagent strip

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Canine Pyometra is a uterine disease that occurs in sexually mature bitches, with higher incidence in nulliparous and animals over 4 years and is characterized by presenting an accumulation of pus in the uterine lumen, usually occurring in diestrus. Laboratory tests are important tools for the detection of metabolic abnormalities associated with sepsis and renal function, which are serious consequences of pyometra. In blood the main findings are normochromic non-regenerative anemia, presence of dehydration, and sometimes thrombocytopenia. The WBC count may be normal but most often occurs a neutrophilic leukocytosis with a left shift, monocytosis and the presence of toxic neutrophils. In less than 1 / 3 of the animals the presence of azotemia is present and a density lower than 1035 is detected in the urine of almost 90% of bitches which may be in normal range at the onset of the desease. Urinary protein loss is rare but the protein may be elevated in the reagent strip due to urinary contamination by uterine secretion. The increase of gamma-glutamyltransferase (GGT), alkaline phosphatase (ALP), aspartate aminotransferase (AST) and creatine kinase (CK) may be present, indicating disorders in the liver. Currently, additional laboratory tests are being studied for the diagnosis of pyometra and its prognosis, such as the measurement of C-reactive protein and fibrinogen for monitoring the recovery of the inflammatory process and the urine electrophoresis to characterize the origin of proteinuria in these animals . The aim of this work is to review the literature on the main laboratory tests that aid the diagnosis of Pyometra

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An enantioselective high-performance liquid chromatographic method for the analysis of carvedilol in plasma and urine was developed and validated using (-)-menthyl chloroformate (MCF) as a derivatizing reagent. Chloroform was used for extraction, and analysis was performed by HPLC on a C18 column with a fluorescence detector. The quantitation limit was 0.25 ng/ml for S(-)-carvedilol in plasma and 0.5 ng/ml for R(+)-carvedilol in plasma and for both enantiomers in urine. The method was applied to the study of enantioselectivity in the pharmacokinetics of carvedilol administered in a multiple dose regimen (25mg/12h) to a hypertensive elderly female patient. The data obtained demonstrated highest plasma levels for the R(+)-carvedilol(AUCSS 75.64 vs 37.29ng/ml). The enantiomeric ratio R(+)/S(-) was 2.03 for plasma and 1.49 0 - 12 for urine (Aeo-12 17.4 vs 11.7 pg). Copyright (c) 2008 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid flow-injection spectrophotometric method is reported for the determination of dipyrone in pharmaceutical formulations. The method is based on the reaction of dipyrone with ammonium molybdate in acidic medium to produce blue molybdenum, which was detected spectrophotometrically at 620 nm. The analyte was determined in a single-line flow system. The calibration curve obtained was linear in the range of 5x10(-4) to 8x10(-3) mol L-1 for dipyrone concentration and the precision ( s r =1.7%) was satisfactory. The method proved to be selective and adequately sensitive. Application of the method to the analysis of pharmaceutical samples resulted in excellent accuracy; the percent mean recoveries were in the range 95.3%-101% and relative errors less than 5.0% for five pharmaceutical formulations were found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho avaliou a PCR na detecção de leptospiras em sêmen e urina de dez touros sorologicamente reagentes, comparando seus resultados com aqueles obtidos por outras técnicas de diagnóstico. Foram realizadas duas colheitas de materiais em dias alternados. As amostras de sêmen e de urina foram separadas em alíquotas para visualização direta em microscopia de campo escuro, inoculação em hamsters (apenas para o sêmen), isolamento em meio de cultura e PCR. Nenhum hamster apresentou positividade na prova de soroaglutinação microscópica (SAM); fragmentos de rins e fígado desses animais foram utilizados para a tentativa de isolamento em meio de cultura, sendo positivo o cultivo a partir do rim de hamster inoculado com semen de um touro, e do fígado de hamsters inoculados com o semen de três touros. O isolamento em meio de cultura foi negativo para todas as amostras de sêmen, mas foi positivo para cinco amostras de urina. Na PCR não houve resultado positivo para as amostras de sêmen, e apenas uma amostra de urina apresentou resultado positivo, sendo coincidente com uma das culturas positivas. Não foi possível visualizar leptospiras em nenhuma das amostras por exame direto em microscopia de campo escuro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of caffeine in racing horses has been of growing concern in veterinary sports medicine since the Association of Racing Commissioners International (ARCI) stated that it has no valid therapeutic use in racehorses. We examined the kinetic alterations in the urinary excretion and salivary secretion of caffeine in seven horses subjected to urinary acidification using ascorbic acid because this procedure can simulate the acidosis that follows anaerobic exercise. They participated in two treatment groups: the control group (SG) received 500 ml of saline and then 2.0 mg kg(-1) caffeine i.v. 30 min later; and the acidified group (AG) was subjected to urinary acidification with ascorbic acid at a dose of 0.5 g kg(-1) i.v. and then 2.0. mg kg(-1) caffeine i.v. 30 min later. Samples were collected 30 min before caffeine administration, immediately before caffeine administration (time zero) and at 0.25, 0.5, 1, 2, 4, 6, 8, 12, 24, 48 and 72 h afterwards. The samples were assayed by gas chromatography. The mean urinary pH for SG was 8.2, but for AG it was as low as 5.9 at 4 h, extending acidosis for up to 8 h. The kinetic curves for the two groups were similar for urinary excretion and salivary secretion. Differences occurred only in peak excretion and peak secretion in SG obtained at 1 h and 30 min, respectively, and in AG at 2 h and 1 h, respectively. This could be explained, in part, to the diuresis in AG compared with SG, resulting in less concentrated urine in the former group. The large difference between the pK(a) of caffeine and the pH of the medium may be responsible for the similar pharmacokinetics observed for the two groups. Copyright (C) 2004 John Wiley Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This method has been developed for extraction and determination of phenol in a urine sample by high performance liquid chromatography.After acid hydrolysis, the free phenol was extracted with isoamyl alcohol solvent, followed by back extraction with 0.5 mol.L-1 sodium hydroxide solution and analyzed by an isocratic HPLC Varian System, equipped with reverse-phase column (MicroPak-C-18). The mobile phase was acetonitrile in 0.01 mol.L-1 hydrochloric acid solution, (20:80 v/v), and at a now-rate of 1.0 mL.min-1. The chromatogram was monitored at 220 nm in room temperature. The identification was based on retention time and the quantification was performed by automatic peak-area determination, corrected for the external standards method.The recovery was higher than 99.5 % for phenol and reproducibility of method was shown to be 2.3% standard deviation and 5.6% coefficient of variance (n=20). The limit detection was 0.05 mgL(-1) and a range of 0.05 to 20.0 mgL(-1) of phenol for linearity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A semi solid thin strip continuous casting process was used to obtain 50%wt Pb/50%wtSn strip by single and twin roll processing at speed of 15 m/min. A 50%wt Pb/50%wtSn plate ingot was also cast for rolling conventionally into strips of 1.4 mm thickness and 45 mm width for comparison with those achieved non-conventionally. This hypoeutectic alloy has a solidification interval and fusion temperature of approximately 31 degrees C and 215 degrees C respectively. The casting alloy temperature was around 280 degrees C as measured by a type K immersion thermocouple prior to pouring into a tundish designed to maintain a constant melt flow on the cooling slope during semi solid material production. A nozzle with a weir ensures that the semi solid material is dragged smoothly by the lower roll, producing strip with minimum contamination of slag/oxide. The temperatures of the cooling slope and the lower roll were also monitored using K type thermocouples. The coiled semi solid strip, which has a thickness of 1.5 mm and 45 mm width, was rolled conventionally in order to obtain 1.2 mm thick strip. The coiled thixorolled strip had a thickness of 1.2 mm and achieved practically the same width as the conventional strips. Blanks of 40 mm diameter were cut from the strips in a mechanical press, ready for deep drawing and ironing for mechanical characterization. All the strips achieved from non-conventional processing had the same mechanical performance as those achieved conventionally. The limiting drawing ratio (LDR) achieved was approximately 2.0 for all strips. Microscopy examination was made in order to observe phase segregation during processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chemical and electrochemical behaviour of the Ti-1 5V-3Cr-3Sn-3Al alloy in Kroll reagent has been studied after ageing at 350-600degreesC, to optimise metallographic etching. Etching tests and polarisation curves showed that samples aged at higher temperatures have been more susceptible to corrosion. It has been attributed to the formation of intra- and intergranular alpha-phase precipitates during ageing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

defect metal alloy strip when thixorolling directly from the semi-solid state. To facilitate the study lead/tin alloys were chosen for their relatively low operating temperature. The objective is to extrapolate these findings to the higher temperature aluminium, alloys. Three alloys (70%Pb30%Sn, 60%Pb-40%Sn, 50%Pb-50%wtSn) were used particularly to study the influence of the solidification interval. The equipment consists of a two roll mill arranged as an upper and lower roller, where both rollers are driven at a controlled speed. The lower roller is fed with semi solid alloy through a ceramic nozzle attached to the lower end of a cooling slope. Several types of nozzle and their position at the roller were tested. This produced different solidifications and consequently different finished strip. The alloys were first cast and then poured onto the cooling slope through a tundish in order to create a continuous laminar flow of slurry and uniformity of metal strip quality. The pouring was tested at different positions along the slope. The cooling slope was coated with colloidal graphite to promote a smooth slurry flow and avoid the problem of adherence and premature solidification. The metallic slurry not only cools along the slope but is also initially super-cooled to a mush by the lower roller whilst at room temperatures, thus enabling thixorolling. It was also found that the nozzle position could be adjusted to enable the upper roller to also contribute to the solidification of the metallic slurry. However the rollers and the cooling slope naturally heat up. Temperature distribution in these zones was analysed by means of three thermocouples positioned along the cooling slope and a fourth in the base of the semi solid pool within the nozzle. The objective being to design an optimum pouring and cooling system. The formed strip was cooled down to room temperature with a shower of water. Microstructures of the thixorolling process were analysed. The differences in solidification conditions resulted in differing qualities of finished strip and corresponding defect types, all of which are a serious quality issue for the rolled product.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study is aimed to determine serum and urine interleukin-8 (IL-8) levels in premature infants with late onset sepsis (LOS) and to evaluate if urine IL-8 is a useful test for LOS diagnosis. Fifty-six premature infants admitted to the NICU over 1 year had serum and urine IL-8 determined by ELISA. They were divided into three groups: I definite sepsis, II probable sepsis and III non-infected. Results were expressed as mean or median. Differences between groups were assessed by ANOVA, Kruskal-Wallis ANOVA and Dunns Method. Sensitivity, specificity and positive and negative predictive values were calculated and a receiver operator characteristic curve was constructed to determine serum and urine IL-8 accuracy. There were no differences between groups for birth weight, and gestational and post-natal age. Median serum and urine IL-8 levels were significantly higher in GI and GII: 929 x 906 x 625pg/ml; P=0.024, and 249 x 189 x 42pg/mgCr; P< 0.001. Optimal cut-off point was 625pg/ml for serum IL-8 with 69 sensitivity and 75pg/mgCr for urine IL-8 with 92 sensitivity. IL-8 can be determined in urine from premature infants with LOS and is an accurate and feasible diagnosis method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Male Holtzman rats weighting 200-250 g were anesthetized with zoletil 50 mg/Kg (tiletamine chloridrate 125,0 mg and zolazepan chloridrate 125,0 mg) into quadriceps muscle and submitted an electrolytic lesion of the lateral hypothalamus (LH) and a stainless steel cannula was implanted into their median preoptic nucleus (MnPO). We investigated the effects of the injection into the (MnPO) of FK 409 (20 mug/0.5 mul), a nitric oxide (NO) donor, and N-W-nitro-L-arginine methyl ester (L-NAME) 40 mug/0.5 mul, a nitric oxide synthase inhibitor (NOSI), on the water and sodium appetite and the natriuretic, diuretic and cardiovascular effects induced by injection of L-NAME and FK 409 injected into MnPO in rats with LH lesions. Controls were injected with a similar volume of 0.15 M NaCl. L-NAME injected into MnPO produced an increase in water and sodium intake and in sodium and urine excretion and increase de mean arterial pressure (MAP). FK 409 injected into MnPO did not produce any change in the hydro electrolytic and cardiovascular parameters in LH-sham and lesioned rats. FK 409 injected before L-NAME attenuated its effects. These data show that electrolytic lesion of the LH reduces fluid and sodium intake as well as sodium and urine excretion, and the pressor effect induced by L-NAME. LH involvement with NO of the MnPO excitatory and inhibitory mechanisms related to water and sodium intake, sodium excretion and cardiovascular control is suggested. (C) 2004 Elsevier B.V. All rights reserved.