14 resultados para ultraviolet laser induction

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

80.00% 80.00%

Publicador:

Resumo:

An all-fiber approach to terahertz generation using a periodically poled optical fiber is proposed and experimentally demonstrated. In the proposed approach, a continuous-wave THz wave is generated at a periodically poled fiber by beating two optical wavelengths from two laser sources with the wavelength spacing corresponding to the frequency of the THz wave. The key component in the system is the periodically poled fiber, which is made by a twin-hole fiber with the fiber core residing between two holes. The twin-hole fiber is then thermally poled at a temperature of similar to 260 degrees C with a voltage of 3.3 kV applied to the silver electrodes inside the two holes to introduce second-order nonlinearity. The quasi phase matching (QPM) condition is achieved by periodically erasing the thermal poling induced second-order nonlinearity with an ultraviolet laser, which enhances the energy conversion efficiency. The proposed approach is validated by an experiment. The emission of a THz wave centered at 3.8 THz with an output power of 0.5 mu W is observed. The frequency tunability between 2.2 and 3.8 THz is also experimentally demonstrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the efficacy of the laser fluorescence (LF) device in detecting in vitro demineralization and remineralization of smooth surface caries-like lesions. Background Data: The early detection of smooth surface caries-like lesions is important to provide proper management of carious lesions, and allows monitoring of them over time. Also, some authors suggest that LF could be useful in monitoring the caries pathological process. Materials and Methods: Seventy-eight blocks of bovine teeth were obtained, and then submitted to artificial caries lesion induction and to a pH-cycling process. Superficial microhardness (SMH) and laser fluorescence analysis were performed at baseline, after induction of caries-like lesions, and after the pH-cycling regimen to promote remineralization. Results: Friedman's and multiple comparison tests were performed for all variables. SMH analysis showed significant differences (p < 0.05) between baseline (286.77 +/- 1.49 Vickers hardness number [VHN] units), before (38.48 +/- 0.85 VHN), and after remineralization (131.93 +/- 2.63 VHN). Baseline values for LF were extremely low (2.71 +/- 0.05), and a statistically significant difference was observed only after remineralization (3.61 +/- 0.08), as demonstrated by the increase in LF values. Conclusion: The LF device did not show efficacy for monitoring in vitro demineralization and remineralization of smooth enamel surfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Therapeutic approaches to chronic actinic cheilitis focus on the removal or destruction of diseased epithelium. The CO(2) laser has become an important therapeutic alternative, achieving clinical resolution in around 90% of patients. Although many laser physical parameters have been reported, some are known for their low potential for scar induction without compromising the success of the results. The aim of this clinicohistological study was to compare the therapeutic responses to two low-morbidity protocols involving a single laser pass. A total of 40 patients with chronic multicentric and microscopically proven disease were randomly submitted to two conservative CO(2) laser protocols using a bilateral comparative model. The degree of histological atypia of the epithelium was determined in 26 patients both pre- and postoperatively for both protocols. Other histological phenomena were assessed in addition to this central analysis parameter. Clinical recurrence occurred in 12.5% of patients for each protocol, together with a significant reduction in the degree of epithelial atypia (p < 0.001), which was occasionally complete. However, no difference was found between the protocols (p > 0.05). Using these morphological parameters it was not possible to determine whether postoperative epithelial atypias in part of the sample were reactive or residual in nature. A few patients may show minor postoperative lesions. Due to their potential to achieve clinical and importantly microscopic resolution, the studied protocols may be used for mild through moderate dysplastic epithelium and clinically diffuse disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When the carious tissue is eliminated either by conventional methods (with burs) or with lasers, the risk of accidentally damage the surface of adjacent teeth may occur, which hypothetically could lead to a more susceptible surface for canes formation. This in vitro study aims to evaluate the caries resistance of the dental enamel surface irradiated by the Nd:YAG laser applied in conditions simulating accidental exposition. Thirteen third molars were used in this study. The experimental groups were: G1: sound control and control + carious; G2: contact Nd:YAG laser at 0.75, 1, 2, or 3 W; 10 Hz; 3 sec (27, 35, 71, and 106 J/cm(2)); G3: same parameters from G2 + caries artificial induction through the demineralization and demineralization (DES/RE) dynamic model. The caries resistance analysis was evaluated by the superficial morphological aspect through SEM images and also by Ca/P proportion through energy dispersive X-ray spectroscopy (EDX). The micrograph images showed that the Nd:YAG laser changed the normalmorphology of the enamel prisms resulting in a melted and re-solidified surface intensified with the power increase. Significant statistical differences were observed applying the Kruskal-Wallis statistical test (p <= 0.01) among the Nd:YAG laser irradiated groups and the control with caries regarding the Ca/P proportion. As an exception, this was not observed when 3 W; 10 Hz; 3 sec; 106 J/cm(2) was applied and posteriously submitted to a cariogenic challenge. The results indicate that the Nd:YAG laser accidental irradiation at low power settings did not represent risks to the enamel caries resistance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present work is to analyze the histological changes on hamster buccal mucosa caused by the topical use of 7,12-dimethylbenzanthracene (DMBA) and exposition to a 220 μJ/pulse nitrogen laser light (@ 337 nm) at an average power of 2,3 mW. Twenty-one hamsters divided into two experimental groups were treated six times with DMBA. One hamster was kept as control. Group I was composed by ten hamsters and was submitted only to DMBA. Group II, also with ten hamsters, received the same treatment as group I and was exposed to the laser radiation. The time duration of each irradiation section was 10 seconds. All the treatment happened in alternated days. The histological analysis took place twice, after the end of the treatment and after sixty days. Both experimental groups presented dilatation of vessels, thickening of the epithelial tissue and the presence of inflammatory infiltrates. The preliminary results indicates that in group II the number of dilated vessels and its new area are much more significant than in group I.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An upconversion random laser (RL) operating in the ultraviolet is reported for Nd 3+ doped fluoroindate glass powder pumped at 575 nm. The RL is obtained by the resonant excitation of the Nd 3+ state 2G 7/2 followed by energy transfer among two excited ions such that one ion in the pair decays to a lower energy state and the other is promoted to state 4D 7/2 from where it decays emitting light at 381 nm. The RL threshold of 30 kW/cm 2 was determined by monitoring the photoluminescence intensity as a function of the pump laser intensity. The RL pulses have time duration of 29 ns that is 50 times smaller than the decay time of the upconversion signal when the sample is pumped with intensities below the RL laser threshold. © 2011 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study aimed to evaluate the droplet spectrum of hydraulic nozzles, under different pressures and spray liquid compositions, using a laser particle size analyzer. In a completely randomized design, two air induction twin flat-fan nozzles (AD-IA/D 11002 and AD-IA/D11004) and two hollow-cone nozzles (MAG - 2 and MAG - 4) were evaluated, in factorial design 3 x 2: tree spray pressures (207, 276 and 345 kPa for twin flat-fan nozzles, and 414, 483 and 552 kPa for cone nozzles); and two spray liquid compositions (water and water plus phosphatydilcoline + propionic acid adjuvant). The addition of adjuvant reduced the volume median diameter for the AD-IA/D 11002 and 11004 nozzles; however it had an opposite effect with the MAG - 4 nozzles and not changed with the MAG - 2 nozzles. In adverse weather conditions, it is not recommended the use of hollow cone spray nozzle, even with the addition of adjuvant tested because of the high risk potential of drift.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)