6 resultados para training cycle
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Papoti, M., L.E.B. Martins, S.A. Cunha, A.M. Zagatto, and C.A. Gobatto. Effects of taper on swimming force and swimmer performance after an experimental ten-week training program. J. Strength Cond. Res. 21(2):538-542. 2007.- The purpose of this research was to examine how an 11-day taper after an 8.5-week experimental training cycle affected lactate levels during maximal exercise, mean force, and performance in training swimmers, independent of shaving, psychological changes, and postcompetition effects. Fourteen competition swimmers with shaved legs and torsos were recruited from the São Paulo Aquatic Federation. The training cycle consisted of a basic training period (endurance and quality phases) of 8.5 weeks, with 5,800 m·d -1 mean training volume and 6 d·wk -1 frequency; and a taper period (TP) of 1.5 weeks' duration that incorporated a 48% reduction in weekly volume without altering intensity. Attained swimming force (SF) and maximal performance over 200m maximal swim (Pmax) before and after taper were measured. After taper, SF and Pmax improved 3.6 and 1.6%, respectively (p < 0.05). There were positive correlations (p < 0.05) between SF and Pmax before (r = 0.86) and after (r = 0.83) the taper phase. Peak lactate concentrations after SF were unaltered before (6.79 ± 1.2 mM) and after (7.15 ± 1.8 mM) TP. Results showed that TP improved mean swimming velocity, but not in the same proportion as force after taper, suggesting that there are other factors influencing performance in faster swimming. © 2007 National Strength & Conditioning Association.
Resumo:
Background: Pulmonary rehabilitation (PR) programs are beneficial to patients with chronic obstructive pulmonary disease (COPD), and lower-extremity training is considered a fundamental component of PR. Nevertheless, the isolated effects of each PR component are not well established. Objective: We aimed to evaluate the effects of a cycle ergometry exercise protocol as the only intervention in a group of COPD patients, and to compare these results with a control group. Methods: 25 moderate-to-severe COPD patients were evaluated regarding pulmonary function, respiratory muscle strength, exercise capacity, quality of life and body composition. Patients were allocated to one of two groups: (a) the trained group (TG; n=13; 6 men) was submitted to a protocol of 24 exercise sessions on a cycle ergometer, with training intensity initially set at a heart rate (HR) close to 80% of maximal HR achieved in a maximal test, and load increase based on dyspnea scores, and (b) the control group (CG; n=12; 6 men) with no intervention during the protocol period. Results: TG showed within-group significant improvements in endurance cycling time, 6-min walking distance test, maximal inspiratory pressure and in the domain 'dyspnea' related to quality of life. Despite the within-group changes, no between-group significant differences were observed. Conclusion: In COPD patients, the results of isolated low-to-moderate intensity cycle ergometer training are not comparable to effects of multimodality and high-intensity training programs. Copyright (C) 2004 S. Karger AG, Basel.
Resumo:
The objectives of this study were: a) to determine, in a cross-sectional manner, the effect of aerobic training on the peak oxygen uptake, the intensity at O2peak and the anaerobic threshold (AnT) during running and cycling; and b) to verify if the transference of the training effects are dependent on the analized type of exercise or physiological index. Eleven untrained males (UN), nine endurance cyclists (EC), seven endurance runners (ER), and nine triathletes (TR) were submitted, on separate days, to incremental tests until voluntary exhaustion on a mechanical braked cycle ergometer and on a treadmill. The values of O2peak (ml.kg-1.min-1) obtained in running and cycle ergometer (ER = 68.8 ± 6.3 and 62.0 ± 5.0; EC = 60.5 ± 8.0 and 67.6 ± 7.6; TR = 64.5 ± 4.8 and 61.0 ± 4.1; UN = 43.5 ± 7.0 and 36.7 ± 5.6; respectively) were higher in the group that presented specific training in the modality. The UN group presented the lower values of O2peak, regardless of the type of exercise. This same behavior was observed for the AnT (ml.kg-1.min-1) determined in running and cycle ergometer (ER = 56.8 ± 6.9 and 44.8 ± 5.7; EC = 51.2 ± 5.2 and 57.6 ± 7.1; TR = 56.5 ± 5.1 and 49.0 ± 4.8; UN = 33.2 ± 4.2 and 22.6 ± 3.7; respectively). It can be concluded that the transference of the training effects seems to be only partial, independently of the index (O2peak, IO2peak or AnT) or exercise type (running or cycling). In relation to the indices, the specificity of training seems to be less present in the O2peak than in the IO2peak and the AnT.
Resumo:
The main purpose of this study was to analyze the effects of exercise mode, training status and specificity on the oxygen uptake ((V)over dot O-2) kinetics during maximal exercise performed in treadmill running and cycle ergometry. Seven runners (R), nine cyclists (C), nine triathletes (T) and eleven untrained subjects (U), performed the following tests on different days on a motorized treadmill and on a cycle ergometer: (1) incremental tests in order to determine the maximal oxygen uptake ((V)over dot O-2max) and the intensity associated with the achievement of (V)over dot O-2max (I(V)over dot O-2max); and (2) constant work-rate running and cycling exercises to exhaustion at I(V)over dot O-2max to determine the effective time constant of the (V)over dot O-2 response (tau(V)over dot O-2). Values for (V)over dotO(2max) obtained on the treadmill and cycle ergometer [R=68.8 (6.3) and 62.0 (5.0); C=60.5 (8.0) and 67.6 (7.6); T=64.5 (4.8) and 61.0 (4.1); U=43.5 (7.0) and 36.7 (5.6); respectively] were higher for the group with specific training in the modality. The U group showed the lowest values for VO2max, regardless of exercise mode. Differences in tau(V)over dot O-2 (seconds) were found only for the U group in relation to the trained groups [R=31.6 (10.5) and 40.9 (13.6); C=28.5 (5.8) and 32.7 (5.7); T=32.5 (5.6) and 40.7 (7.5); U=52.7 (8.5) and 62.2 (15.3); for the treadmill and cycle ergometer, respectively]; no effects of exercise mode were found in any of the groups. It is concluded that tauVO(2) during the exercise performed at I(V)over dot O-2max is dependent on the training status, but not dependent on the exercise mode and specificity of training. Moreover, the transfer of the training effects on tau(V)over dotO(2) between both exercise modes may be higher compared with (V)over dot O-2max.
Resumo:
The aim of the study was to verify whether 8 weeks of resistance training employing maximal isokinetic eccentric (IERT) knee extensor actions would reduce the acute force loss observed after high-intensity treadmill running exercise. It was hypothesized that specific IERT would induce protective effects against muscle fatigue and ultrastructural damages, preventing or reducing the loss in mechanical muscle function after running. Subjects were tested before and after IERT protocol for maximal isometric, concentric and eccentric isokinetic knee extensor strength (60 and 180 s-1). In a second session, subjects performed treadmill running (~35 min) and the previously mentioned measurements were repeated immediately after running. Subsequently, subjects were randomized to training (n = 12) consisting of 24 sessions of maximal IERT knee extensors actions at 180 s-1, or served as controls (n = 8). The effects of acute running-induced fatigue and training on isokinetic and isometric peak torque, and rate of force development (RFD) were investigated. Before IERT, running-induced eccentric torque loss at 180 s-1 was -8 %, and RFD loss was -11 %. Longitudinal IERT led to reduced or absent acute running-induced losses in maximal IERT torque at 180 s-1 (+2 %), being significantly reduced compared to before IERT (p < 0.05), however, RFD loss remained at -11 % (p > 0.05). In conclusion, IERT yields a reduced strength loss after high-intensity running workouts, which may suggest a protective effect against fatigue and/or morphological damages. However, IERT may not avoid reductions in explosive muscle actions. In turn, this may allow more intense training sessions to be performed, facilitating the adaptive response to running training. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)