176 resultados para toxic limit of selenium in pisciculture

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a simple, fast and sensitive method to determine selenium in samples of feces and of fish feed by graphite furnace atomic absorption spectrometry (GFAAS) through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The limits of detection (LOD) and quantification (LOQ calculated for 20 readings of the blank of the standard slurries (0.50% m/v of feces or feed devoid of selenium) were 0.31 mu g 1(-1) and 1.03 mu g 1(-1), respectively, for the standard feces slurries and 0.35 mu g 1(-1) and 1.16 mu g 1(-1), respectively, for the standard feed slurries. The proposed method was applied in studies of bioavailability of selenium in different fish feeds and the results proved consistent with that obtained from samples mineralized by acid digestion using the microwave oven. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method has been developed for the direct determination of Se in nutritionally relevant foods by graphite furnace atomic absorption spectrometry. Tungsten/rhodium carbide coating on the integrated platform of a transversely heated graphite atomizer or W coating with co-injection of Pd(NO3)(2) were used as a permanent modifiers. Samples and reference solutions were spiked with 500 mu g L-1 As and absorbance variations due to changes in experimental conditions were minimized. For 20 mu L aqueous analytical solutions delivered into the graphite tube, analytical curves in the 5.0-40 mu g L-1 with good linear correlation were established. Pyrolysis and atomization temperatures were evaluated using pyrolysis and atomization curves, respectively. The optimized heating program (temperature, ramp time, hold time) of the graphite tube of the Perkin-Elmer SIMAA 6000 atomic absorption spectrometer was: dry steps (110 degrees C, 5 s, 10 s; 130 degrees C, 15 s, 15 s); air-assisted pyrolysis step (600 degrees C, 20 s, 40 s; 20 degrees C, 1 s, 40 s); pyrolysis step (1300 degrees C, 10 s, 20 s); atomization step (2100 degrees C, 0 s, 4 s); clean step (2550 degrees C, 1 s, 5 s). The method was applied for Se determination in coconut water, coconut milk, soybean milk, cow milk, tomato juice, mango juice, grape juice and drinking water samples and four standard reference materials and results were in agreement at 95% confidence level. The lifetime of the tube was 500 firings and the relative standard deviations of measurements of typical samples containing 25 mu gL(-1) Se were 3.0% and 6.0% (n = 12) with and without internal standardization, respectively. The limits of detection were in the 0.35 mu g L-1-0.7 mu g Se L-1 range. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values were in the 98-109% range. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We studied the efficacy of hydrated sodium calcium aluminosilicate (HSCAS) as an inhibitor of the toxic effects of ochratoxin in broilers from 1 to 42 d of age. A total of 288 broilers was distributed into four treatments with four replicates of 18 birds each: T1, control; T2, 0.25% HSCAS; T3, 2 ppm of ochratoxin; T4, 0.25% HSCAS + 2 ppm ochratoxin. The parameters evaluated were feed intake; weight gain; feed conversion; relative weights of the liver, kidneys, and bursa; and serum levels of Ca, P, total protein (TP), aspartate aminotransferase (AST) and γ-glutamiltransferase (GGT). Ochratoxin in the diet negatively affected (P < 0.05) all performance parameters evaluated when the birds were 21 and 42 d of age. However, HSCAS did not affect performance, and there was no interaction between HSCAS and dietary ochratoxin. The liver and the kidneys of birds fed ochratoxin with or without HSCAS were relatively heavier (P < 0.05) than those of the control birds, demonstrating the influence of ochratoxin, but not of HSCAS, on the relative weight of these organs. Although the bursa of birds exposed to ochratoxin with or without HSCAS had a lower relative weight as compared to control birds, the difference was not significant. Ca, P, and TP serum levels were lower (P < 0.05) in birds exposed to ochratoxin, whereas AST and GGT levels were higher (P < 0.05) in these birds. These results reflect that ochratoxin in the diet impaired the productivity indexes and that HSCAS did not improve these parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This pilot study uses concentrations of metals in maternal and cord blood at delivery, in seven selected geographical areas of South Africa, to determine prenatal environmental exposure to toxic metals. Samples of maternal and cord whole blood were analysed for levels of cadmium, mercury, lead, manganese, cobalt, copper, zinc, arsenic and selenium. Levels of some measured metals differed by site, indicating different environmental pollution levels in the regions selected for the study. Mercury levels were elevated in two coastal populations studied (Atlantic and Indian Ocean sites) with mothers from the Atlantic site having the highest median concentration of 1.78 mu g/L ranging from 0.44 to 8.82 mu g/L, which was found to be highly significant (p < 0.001) when compared to other sites, except the Indian Ocean site. The highest concentration of cadmium was measured in maternal blood from the Atlantic site with a median value of 0.25 mu g/L (range 0.05-0.89 mu g/L), and statistical significance of p < 0.032, when compared to all other sites studied, and p < 0.001 and p < 0.004 when compared to rural and industrial sites respectively, confounding factor for elevated cadmium levels was found to be cigarette smoking. Levels of lead were highest in the urban site, with a median value of 32.9 mu g/L (range 16-81.5 mu g/L), and statistically significant when compared with other sites (p < 0.003). Levels of selenium were highest in the Atlantic site reaching statistical significance (p < 0.001). All analysed metals were detected in umbilical cord blood samples and differed between sites, with mercury being highest in the Atlantic site (p < 0.001), lead being highest in the urban site (p < 0.004) and selenium in the Atlantic site (p < 0.001). To the best of our knowledge this pilot investigation is the first study performed in South Africa that measured multiple metals in delivering mothers and umbilical cord blood samples. These results will inform the selection of the geographical sites requiring further investigation in the main study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Throughout the world, biomonitoring has become the standard for assessing exposure of individuals to toxic elements as well as for responding to serious environmental public health problems. However, extensive biomonitoring surveys require rapid and simple analytical methods. Thus, a simple and high-throughput method is proposed for the determination of arsenic (As), cadmium (Cd), copper (Cu), manganese (Mn), nickel (Ni), lead (Pb), and selenium (Se) in blood samples by using inductively coupled plasma-mass spectrometry (ICP-MS). Prior to analysis, 200 l of blood samples was mixed with 500 l of 10% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 10 min, and subsequently diluted to 10 ml with a solution containing 0.05% w/v ethylenediamine tetraacetic acid (EDTA) + 0.005% v/v Triton X-100. After that, samples were directly analyzed by ICP-MS (ELAN DRC II). Rhodium was selected as an internal standard with matrix-matching calibration. Method detection limits were 0.08, 0.04, 0.5, 0.09, 0.12, 0.04, and 0.1 g//L for As, Cd, Cu, Mn, Ni, Pb, and Se, respectively. Validation data are provided based on the analysis of blood samples from the trace elements inter-\comparison program operated by the Institut National de Sante Publique du Quebec, Canada. Additional validation was provided by the analysis of human blood samples by the proposed method and by using electrothermal atomic absorption spectrometry (ETAAS). The method was subsequently applied for the estimation of background metal blood values in the Brazilian population. In general, the mean concentrations of As, Cd, Cu, Mn, Ni, Pb, and Se in blood were 1.1, 0.4, 890, 9.6, 2.1, 65.4, and 89.3 g/L, respectively, and are in agreement with other global populations. Influences of age, gender, smoking habits, alcohol consumption, and geographical variation on the values were also considered. Smoking habits influenced the levels of Cd in blood. The levels of Cu, Mn, and Pb were significantly correlated with gender, whereas Cu and Pb were significantly correlated with age. There were also interesting differences in Mn and Se levels in the population living in the north of Brazil compared to the south.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Throughout the world, biomonitoring has become the standard for assessing exposure of individuals to toxic elements as well as for responding to serious environmental public health problems. However, extensive biomonitoring surveys require rapid and simple analytical methods. Thus, a simple and high-throughput method is proposed for the determination of arsenic (As), cadmium (Cd), copper (Cu), manganese (Mn), nickel (Ni), lead (Pb), and selenium (Se) in blood samples by using inductively coupled plasma–mass spectrometry (ICPMS). Prior to analysis, 200 ml of blood samples was mixed with 500 ml of 10% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 10 min, and subsequently diluted to 10 ml with a solution containing 0.05% w/v ethylenediamine tetraacetic acid (EDTA) + 0.005% v/v Triton X-100. After that, samples were directly analyzed by ICP-MS (ELAN DRC II). Rhodium was selected as an internal standard with matrix-matching calibration. Method detection limits were 0.08, 0.04, 0.5, 0.09, 0.12, 0.04, and 0.1 mg//L for As, Cd, Cu, Mn, Ni, Pb, and Se, respectively. Validation data are provided based on the analysis of blood samples from the trace elements inter-\comparison program operated by the Institut National de Santé Publique du Quebec, Canada. Additional validation was provided by the analysis of human blood samples by the proposed method and by using electrothermal atomic absorption spectrometry (ETAAS). The method was subsequently applied for the estimation of background metal blood values in the Brazilian population. In general, the mean concentrations of As, Cd, Cu, Mn, Ni, Pb, and Se in blood were 1.1, 0.4, 890, 9.6, 2.1, 65.4, and 89.3 mg/L, respectively, and are in agreement with other global populations. Influences of age, gender, smoking habits, alcohol consumption, and geographical variation on the values were also considered. Smoking habits influenced the levels of Cd in blood. The levels of Cu, Mn, and Pb were significantly correlated with gender, whereas Cu and Pb were significantly correlated with age. There were also interesting differences in Mn and Se levels in the population living in the north of Brazil compared to the south.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study was carried out with the objective of evaluating the effects of feeding dairy cows with organic or inorganic sources of zinc (Zn), copper (Cu) and selenium (Se) on blood concentrations of these minerals, blood metabolic profiles, nutrient intake and milk yield and composition. Nineteen Holstein cows were selected and randomly assigned to two groups for receiving organic (n = 9) or inorganic (n = 10) sources of Zn, Cu and Se from 60 days before the expected date of calving to 80 days of lactation. Samples of feed, orts and milk were collected for analysis. Body condition score (BCS) was determined and blood samples were collected for analysis of Zn, Cu and Se concentrations, as well as for metabolic profile. Supplying organic or inorganic sources of Zn, Cu, and Se did not affect dry matter and nutrient intake, blood metabolic profile, milk yield and composition, plasma concentration of these minerals, and BCS or change the BCS in cows from 60 days before the expected date of calving to 80 days of lactation. An effect of time was observed on all feed intake variables, plasma concentrations of Zn and Se, milk yield, milk protein content, BCS and change in BCS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a simple, fast and sensitive method to determine chromic oxide (used as a biological marker of fish feed) in samples of fish feces by GFAAS through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The standard samples of feces and of fish feed containing 0.10-1.00 mg kg(-1) of Cr2O3 were pre-frozen for I min in liquid nitrogen and then ground a cryogenic mill for 2 min, which reduced the samples' grain size to less than 60 mu m. The standard slurries were prepared by mixing 20 mg of standard samples of fish feed or feces with I mL of a solution containing 0.05% (v/v) of Triton X-100 and 0.50% (v/v) of suprapure HNO3 directly in the spectrometer's automatic sampling glass. The final concentrations of Cr2O3 present in the standard slurries were 2, 4, 8, 16 and 20 mu g L-1. After sonicating the mixture for 20s, 10 mu L of standard slurries were injected into the graphite tube, whose internal wall was lined with a metallic palladium film that acted as a permanent chemical modifier. The limits of detection (LOD) and quantification (LOQ) calculated for 20 readings of the blank of the standard slurries (2%, m/v of feces or feed devoid of minerals) were 0.81 and 2.70 mu g L-1 of Cr2O3 for the standard feces slurries, 0.84 and 2.83 mu g L-1 of Cr2O3 for the standard feed slurries. The proposed method was applied in studies of nutrient digestibility of different fish feeds and its results proved compatible with the results obtained from samples pre-mineralized by acid digestion. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A prostaglandina F2a pode ser usada em caes para aumentar o volume do ejaculado em casos de inseminação artificial, criopreservação seminal ou biotecnologias de reprodução. Os efeitos colaterais após a administração da PGF2a, como taquicardia, salivação, emese, diarréia e convulsões geralmente são relacionadas com a dose utilizada. Esse trabalho objetiva relatar a ocorrência de hepatite tóxica aguda após a administração de PGF2a em um cão, e discutir a importância de se utilizar essa droga com cautela nessa espécie.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to investigate the influence of the type of vehicle (distilled water or propyleneglycol) on the response of apical tissues of dogs' teeth after root canal filling with mineral trioxide aggregate (MTA) at two different limits. Forty roots of incisors and premolars of two adult dogs were used. After pulpectomy, the root canals were prepared biomechanically, and the roots had the apical cemental barrier penetrated with a #15 K-file and widened to a #25 K-file. The root canals were assigned to four groups according to the vehicle used for MTA (ProRoot-MTA; Tulsa Dental, Tulsa, OK) preparation and the limit of root canal filling: group 1, filling with MTA/distilled water to the limit of the cemental canal; group 2, overfilling with MTA/distilled water, group 3, filling with MTA/propyleneglycol to the limit of the cemental canal; and group 4, overfilling with MTAlpropyleneglycol. The animals were killed by anesthetic overdose 90 days after endodontic treatment and the anatomic pieces were prepared for histomorphological analysis. The sections were stained with hematoxylin and eosin and Brown and Brenn techniques. The results showed that MTA pastes prepared with either distilled water or propyleneglycol as vehicles had similar biological behavior (p > 0.05); root fillings placed at the cemental canal limit showed better results than the overfillings (p = 0.01), and MTA/propyleneglycol paste was more easily placed into the root canals than MTA/distilled water paste.