106 resultados para tip and casing
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
This study evaluated the Knoop hardness and polymerization depth of a dual-cured resin cement, light-activated at different distances through different thicknesses of composite resin. One bovine incisor was embedded in resin and its buccal surface was flattened. Dentin was covered with PVC film where a mold (0.8-mm-thick and 5 mm diameter) was filled with cement and covered with another PVC film. Light curing (40 s) was carried out through resin discs (2, 3, 4 or 5 mm) with a halogen light positioned 0, 1, 2 or 3 mm from the resin surface. After storage, specimens were sectioned for hardness measurements (top, center, and bottom). Data were subjected to split-plot ANOVA and Tukey's test (α=0.05). The increase in resin disc thickness decreased cement hardness. The increase in the distance of the light curing tip decreased hardness at the top region. Specimens showed the lowest hardness values at the bottom, and the highest at the center. Resin cement hardness was influenced by the thickness of the indirect restoration and by the distance between the light-curing unit tip and the resin cement surface.
Resumo:
The adhesion force between an atomic force microscope (AFM) tip and sample surfaces, mica and quartz substrates, was measured in air and water. The force curves show that the adhesion has a strong dependence on both the surface roughness and the environmental conditions surrounding the sample. The variability of the adhesion force was examined in a series of measurements taken at the same point, as well as at different places on the sample surface. The adhesion maps obtained from the distribution of the measured forces indicated regions contaminated by either organic compounds or adsorbed water. Using simple mathematical expressions we could quantitatively predict the adhesion force behavior in both air and water. The experimental results are in good agreement with theoretical calculations, where the adhesion forces in air and water were mostly associated with capillary and van der Waals forces, respectively. A small long-range repulsive force is also observed in water due to the overlapping electrical double-layers formed on both the tip and sample surfaces.
Resumo:
Purpose: To evaluate the influence of the brush type as a earner of priming adhesive solutions and the use of paper points as a remover of the excess of these solutions on the push-out bond strength of resin cement to bovine root dentin. The null hypotheses were that brush type and the use of paper points do not affect the bond strength. Materials and Methods: The canals of 80 single-root bovine roots (16 mm in length) were prepared at 12 mm using the preparation drill (FRC Postec Plus, Ivoclar). Half of each root was embedded in acrylic resin and the specimens were divided into 8 groups, considering the factors brush type (4 levels) and paper point (2 levels) (n = 10): Gr 1: small microbrush (Cavi-Tip, SDI); Gr 2: Microbrush (Dentsply); Gr 3: Endobrush (Bisco); Gr 4: conventional brush (Bisco); Gr 5: Cavi-Tip (SDI) + paper points; Gr 6: Microbrush (Dentsply) + paper points; Gr 7: Endobrush (Bisco) + paper points; Gr 8: conventional brush (Bisco) + paper points. The root dentin was treated with a multistep total-etch adhesive system (All Bond 2). The adhesive system was applied using each microbrush, with and without using paper points. One fiber post was molded with addition silicon and 80 posts were made of resin cement (Duolink), The resin posts were luted (Duolink resin cement), and the specimens were stored for 24 h in water at 37°C. Each specimen was cut into 4 disk-shaped samples (1.8 mm in thickness), which were submitted to the push-out test. Results: The brush type (p < 0.0001) (small microbrush > microbrush = endobrush = conventional brush) and the use of paper points (p = 0.0001) (with > without) influenced the bond strength significantly (two-way ANOVA). The null hypotheses were rejected. Conclusion: The smallest brush (Cavi-Tip) and the use of paper points significantly improved the resin bond to bovine root dentin.
Resumo:
The aim of this paper was to compare the dentin-pulp complex response to cavity preparation in human teeth using ultrasonic chemical vapor deposition (CVD) diamond tip and high-speed diamond bur. Class V buccal cavities were randomly prepared in 40 premolars from 14 patients aged 11 to 15 years. The cutting time was recorded and the cavities had the axial walls protected with gutta-percha and were filled with glass ionomer cement. The teeth were extracted at intervals of 0, 5, 10 and 20 days, and were decalcified, sectioned and stained by Hematoxylin & Eosin, Masson's Trichrome and Brown & Brenn techniques. The inflammatory response and cell disorganization were blindly evaluated by two examiners. The remaining dentin thickness (RDT) was measured by a linear scale using computer software. Statistical analysis by one-way ANOVA showed no statistically significant difference (P≤0.05) among the cavities prepared with either type of instrument, with mean RDT of 1132.50 mm. Cutting time and the pulp-dentin complex responses were analyzed statistically by Kruskal-Wallis and Dunn tests (P≤0.05). The ultrasonic CVD diamond tip took 5 times longer to prepare the cavities and there were no typical inflammatory pulp responses in cavities prepared with either type of cutting instrument, only mild to moderate cell disorganization was present. Even taking longer to cut the dental substrate, the ultrasonic CVD diamond tip produced similar pulp response compared to the conventional high-speed diamond bur.
Resumo:
Aim To assess the dimensional characteristics, flexibility and torsional behaviour of nickel-titanium retreatment instruments. Methodology Using image analysis software and high-resolution digital images, the instrument length, tip angle, diameter at 3mm from the tip and the distance between the blades (pitch length) of the following eight instruments were measured (n=12 for each measurement parameter): the ProTaper Universal retreatment (PTU-R) D1, D2 and D3 instruments; the R-Endo R1, R2 and R3 retreatment instruments; and the Mtwo retreatment (Mtwo-R) sizes 25 and 15 retreatment instruments. Maximum torque and the angular deflection at fracture as well as the bending moment at 45° were measured (n=12) according to the International Standards Organisation (ISO) specification number 3630-1. Data were analysed using the analysis of variance (α=0.05). Results The length of the active part of the instruments was found to vary according to the depth of the canal into which they were designed to reach. The pitch length also increased along the active length. The PTU-R D1 and the Mtwo-R instruments had active tips. Measurements of the bending moment at 45° revealed that the Mtwo-R 15 instrument was the most flexible, whereas the PTU-R D1 was the least flexible. The maximum torque tended to increase as the instrument diameter at 3mm from the tip increased, whereas the angular deflection at fracture varied in the opposite direction. Conclusions The geometrical characteristics of the retreatment instruments and their flexibility and torsion behaviour were consistent with their intended clinical application. © 2011 International Endodontic Journal.
Resumo:
Introduction: Lateral condensation effectiveness may be influenced by the gutta-percha and finger spreader taper used during root canal obturation. Objective: To evaluate the penetration ability of finger spreader into simulated root canals prepared using MTwo rotary system and filled with different gutta-percha and finger spreader tapers. Material and methods: Resin blocks with curved root canals had the apical diameter enlarged up to #25.06 and distributed into groups (n = 6) according to the gutta-percha taper (#25.02, #25.04, and #25.06) and the finger spreader (#30 and #35 NiTi, and stainless steel B) used to perform cold lateral condensation. After applying a load of 1.5 Kg over the finger spreaders’ head, the distance between the finger spread tip and the apical limit of the root canal preparation were obtained. The data were submitted to Anova and Tukey-Krammer’s test, with 5% of significance. Results: The gutta-percha cones with 0.02 taper enabled higher finger spreader penetration when compared to 0.04 and 0.06 tapers (p < 0.05), which were similar between each other (p > 0.05), regardless of the type and diameter of the finger spreader used. When different finger spreaders were compared among themselves, stainless steel B showed higher penetration ability (p < 0.05). Conclusion: It was concluded that the stainless-steel finger spreaders showed superior penetration ability and gutta-percha with lower tapers enabled a more effective lateral condensation at the apical third.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Para compreender as lesões desportivas (LD) é necessário quantificá-las, associando-as a fatores causais particulares ao esporte. Contudo, faltam registros sobre tais agravos nas instituições esportivas, sobretudo no atletismo brasileiro, em que poucos clubes possuem serviços de assistência à saúde. Na ausência de tais registros, estudos na área de saúde pública, utilizam-se de outros recursos epidemiológicos para coletas, tais como os inquéritos de morbidade referida. A partir dessa escassez de informações e a facilidade de obtenção de dados junto aos próprios atletas, objetivou-se, para esta pesquisa, levantar informações sobre LD referidas por atletas de alto rendimento, retrocedendo em oito meses, e compará-las com os registros de prontuários clínicos. Para tanto, foram tomados 25 atletas de elite, 16 do gênero masculino e nove do feminino, com idade de 25,7 ± 4,4 anos, altura de 1,74 ± 0,10m, peso 70,4 ± 13,15kg e tempo médio de treinamento de 8,38 ± 4,06 anos. Dois fisioterapeutas foram treinados separadamente para coletar informações sobre LD. Um deles em prontuários e o outro dos próprios atletas, através de entrevista (inquéritos de morbidade referida - IMR). Estudo de concordância de respostas para as duas formas de coleta foi realizado pelo teste da proporção binomial, estabelecendo-se limites de 95% de confiança para a concordância. Os resultados mostraram que em todas as variáveis estudadas os valores estavam dentro dos limites de confiança estabelecidos pelos testes estatísticos, sendo: 88,33% para as variáveis tipo de lesão ou agravo e mecanismo de lesão ou aumento dos sintomas, 90% para a variável qualidade do retorno às atividades desportivas e 91,67% para as variáveis local anatômico e período de treinamento. Concluiu-se que houve elevada taxa de concordância entre as informações levantadas, mostrando a eficácia do IMR para a coleta de informações sobre lesões desportivas para a população investigada.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O objetivo deste trabalho foi comparar in vitro a efetividade de três métodos de diagnóstico da lesão de cárie em 26sítios de interesse, dispostos na face palatina de 20 coroas de dentes caninos permanentes de humanos. Quatro examinadores receberam orientação teórico-prática para o diagnóstico, através de três métodos: inspeção visual; táctil (inspeção visual - sonda exploradora com ponta romba); e videoscópico (sistema AcuCam). Para a validação dos dados, os dentes foram seccionados paralelamente ao seu longo eixo por um disco de diamante e analisados histologicamente em um microscópio estereoscópico com aumento de 40X. Diagnósticos compatíveis com o exame histológico apresentaram percentual de acerto no método de inspeção visual de 40,4%, no exame táctil de 38,5% e no videoscópico de 41,3%, resultados que não demonstraram diferença estatisticamente significante. Concluiu-se, pelos resultados obtidos, que os três métodos apresentaram acuidade semelhante no diagnóstico da lesão de cárie; dentre os métodos estudados, o exame ao videoscópio foi o que mais se aproximou do histológico, seguido pelo visual; o mais distante foi o táctil. Constatou-se também uma elevada porcentagem de erro de diagnósticos (59,9%), o que conseqüentemente acarretaria uma conduta terapêutica inadequada
Resumo:
Fiddler crabs are deposit feeders, and use the setae on their mouth appendages to manipulate sediment particles to extract food. The number of spoon-tipped setae on the second maxilliped is frequently related to the distribution of fiddler crabs on estuarine sediments, but no study has compared the morphological diversity of these setae among multiple fiddler crab species. Here, we describe and classify the setae of the second maxillipeds of the nine Uca spp. known from the Brazilian coast. The second maxilliped of each species was examined by scanning electron microscopy. Six types of setae (five papposerrate, and one pappose) were described on the meropodite of the second maxilliped. Among the papposerrate setae, one type had a spoon-like tip, and the morphology of this type, especially the degree of curvature, differed between species. Members of Uca leptodactylus, U. uruguayensis, and U. maracoani had highly concave spoon-tipped setae. In U. rapax and U. cumulanta, the setal tip was moderately curved, while in U. thayeri, U. burgersi, and U. mordax, this curvature was slight. At the other extreme, the meropodite of the second maxilliped of U. vocator lacked setae altogether. This is the first study that describes differences in the degree of curvature of spoon-tipped setae in fiddler crabs. This trait may be strongly related to the distribution of these fiddler crabs on different estuarine substrates. © 2012, The American Microscopical Society, Inc.
Resumo:
The aim of this study was to evaluate the compressive strength of microhybrid (Filtek™ Z250) and nanofilled (Filtek™ Supreme XT) composite resins photo-activated with two different light guide tips, fiber optic and polymer, coupled with one LED. The power density was 653 mW cm -2 when using the fiber optic light tip and 596 mW cm-2 with the polymer. After storage in distilled water at 37 ± 2 °C for seven days, the samples were subjected to mechanical testing of compressive strength in an EMIC universal mechanical testing machine with a load cell of 5 kN and speed of 0.5 mm min-1. The statistical analysis was performed using ANOVA with a confidence interval of 95% and Tamhane's test. The results showed that the mean values of compressive strength were not influenced by the different light tips (p > 0.05). However, a statistical difference was observed (p < 0.001) between the microhybrid composite resin photo-activated with the fiber optic light tip and the nanofilled composite resin. Based on these results, it can be concluded that microhybrid composite resin photo-activated with the fiber optic light tip showed better results than nanofilled, regardless of the tip used, and the type of the light tip did not influence the compressive strength of either composite. Thus, the presented results suggest that both the fiber optic and polymer light guide tips provide adequate compressive strength to be used to make restorations. However, the fiber optic light tip associated with microhybrid composite resin may be an interesting option for restorations mainly in posterior teeth. © 2013 Astro Ltd.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)