36 resultados para testing method
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
This paper presents a semi-automated method for extracting road segments from medium-resolution images based on active testing and edge analysis. The method is based on two sequential and independent stages. Firstly, an active testing method is used to extract an approximated road centreline which is based on a sequential and local exploitation of the image. Secondly, an iterative strategy based on edge analysis and the approximated centreline is used to measure precisely the road centreline. Based on the results obtained using medium-resolution test images, the method seems to be very promising. In general, the method proved to be very accurate whenever the roads are characterized by two well-defined anti-parallel edges and robust even in the presence of larger obstacles such as trees and shadows.
Resumo:
TEMA: programa de treinamento auditivo em escolares com distúrbio de aprendizagem. OBJETIVOS: verificar a eficácia de um programa de treinamento auditivo em escolares com distúrbio de aprendizagem e comparar os achados dos procedimentos de avaliação utilizados nas pré e pós-testagem em escolares com distúrbio de aprendizagem e sem dificuldades de aprendizagem, submetidos e não submetidos ao programa de treinamento auditivo. MÉTODO: participaram deste estudo 40 escolares, sendo que esses foram divididos em: GI, subdividido em: GIe (10 escolares com distúrbio de aprendizagem submetidos ao programa de treinamento auditivo), GIc (10 escolares com distúrbio de aprendizagem não submetidos ao programa de treinamento auditivo) e GII, subdividido em: GIIe (10 escolares sem dificuldades de aprendizagem submetidos ao programa de treinamento auditivo) e GIIc (10 escolares sem dificuldades de aprendizagem não submetidos ao programa de treinamento auditivo). Foi realizado o programa de Treinamento Auditivo Audio Training®. RESULTADOS: os resultados mostraram que o GI apresentou desempenho inferior ao de GII em atividades relacionadas com as habilidades auditivas e de consciência fonológica. O GIe e o GIIe apresentaram melhor desempenho em habilidades auditivas e de consciência fonológica depois da aplicação do programa de treinamento auditivo, quando comparados os achados de pré e pós-testagem. CONCLUSÃO: o desempenho de escolares com distúrbio de aprendizagem nas tarefas auditivas e fonológicas apresenta-se inferior no que concerne ao de escolares sem distúrbio de aprendizagem. A utilização do programa de treinamento auditivo mostrou-se eficaz e possibilitou aos escolares o desenvolvimento dessas habilidades.
Resumo:
The need for a rational use of water and supply of food for a growing world population have led to the development of research in the area of irrigation systems. Thus, some irrigation systems which join efficiency with low cost of material have been developed. Although some technical characteristics are provided by the manufacturers, tests are required to verify functioning of the system and uniformity of water distribution. Continuous research on uniformity, characteristics of the materials and design of water distribution systems is essential for system improvement. Therefore, the objective of this work was to evaluate the CV (manufacturer's coefficient of variation) of Amanco microsprinkler (1.0 mm light green nipple) using bench testing in the laboratory of Irrigation at UNESP - FCA campus of Botucatu-SP. Twenty-five microsprinklers in a sequential design were used in the tests. Three flow systems were tested as follows: a Coil system based on serial connected pipes; a Lateral system, the most common system in which secondary lines are fed by a main line; and a Mesh system used in the urban water supply. The results showed that 4.17% CVf met the production standards and the Lateral and Mesh systems were similar regarding outflow using bench testing. The Mesh system presented the highest mean value of outflow and the lowest range of variation.
Resumo:
Trinta Candida albicans isoladas de pacientes portadores de candidose oral e 30 Candida albicans isoladas de indivíduos controle foram estudadas. Testes de susceptibilidade in vitro foram realizados com anfotericina B, fluconazol, 5-flucitosina e itraconazol pelo método do Clinical and Laboratorial Standars Institute (CLSI) e por E-test. Os resultados obtidos foram analisados e comparados. Os valores de CIM foram semelhantes para amostras isoladas de pacientes portadores de candidose oral e indivíduos controle. A concordância entre os dois métodos foi de 66,7% para a anfotericina B, 53,33% para o fluconazol, 65% para a flucitosina e 45% para o itraconazol. de acordo com estes resultados, o método do E-test poderia ser uma alternativa para a triagem de casos de rotina pela sua simplicidade. Entretanto, este método não pode ser considerado como um substituto para o método de referência do CLSI.
Resumo:
Human fungal infections have increased at an alarming rate in recent years, particularly in immunocompromised individuals. Cryptococcosis is the second most prevalent systemic fungal infection worldwide, and the most prevalent systemic infection in immunocompromised individuals, representing more than 70% of cases. The incidence of cryptococcosis is high in people with HIV/acquired immunodeficiency syndrome (AIDS), with recent estimates indicating that there are one million cases of cryptococcal meningitis globally per year in AIDS patients. The aim of this research was to develop a rapid flow cytometric antifungal susceptibility test and to compare the results with the standard methods. A reference strain and clinical isolates of Cryptococcus neoformans and Cryptococcus gattii were tested for susceptibility to amphotericin B by flow cytometry using propidium iodide as indicator of viability. Flow cytometry (FC) results were compared with the minimum inhibitory concentration (MIC) values determined by microdilution. The antifungal activity of amphotericin B ranged from MICs of 0.06 to 2μg/ml for the 11 isolates studied. The same results were found by FC. The FC method allows same-day results, assisting in the selection of appropriate antifungal therapies. These results demonstrate an excellent correlation between FC and the classic methods of testing for susceptibility to antifungal agents. This rapid diagnosis method makes it possible to quickly administer effective therapeutic interventions, often saving lives.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fiber metal laminates (FML) offer significant improvements over current available materials for aircraft structures due to their excellent mechanical characteristics and relatively low density. Non-destructive testing techniques are being used in the characterization of composite materials. Among these, vibration testing is one of the most used tools because it allows the determination of the mechanical properties. In this work, the viscoelastic properties such as elastic (E') and viscous (E) responses were obtained for aluminum 2024 alloy; carbon fiber/epoxy; glass fiber/epoxy and their hybrids aluminum 2024 alloy/carbon fiber/epoxy and aluminum 2024 alloy/glass fiber/epoxy composites. The experimental results were compared to calculated E modulus values by using the composite micromechanics approach. For all specimens studied, the experimental values showed good agreement with the theoretical values. The damping behavior, i.e. The storage modulus and the loss factor, from the aluminum 2024 alloy and fiber epoxy composites can be used to estimate the viscoelastic response of the hybrid FML. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study tested the bond strength of a resin cement to a glass-infiltrated zirconia-alumina ceramic after three conditioning methods and using two test methods (shear-SBS versus microtensile-MTBS). Ceramic blocks for MTBS and ceramic disks for SBS were fabricated. Three surface conditioning (SC) methods were evaluated: (1) 110-mu m Al(2)O(3)+Silanization; (2) Chairside silica coating+silanization: (3) Laboratory silica coating+silanization. Following surface conditioning, the resin cement (Panavia F) was bonded to the conditioned ceramics. Although no statistically significant differences (p=0.1076) were seen between the test methods, results yielded with the different surface conditioning methods showed statistically significant differences (p<0.0001) (SC2=SC3>SC1.). As for the interaction between the factors, two-way ANOVA showed that it was not statistically significant (p=0.1443). MTBS test resulted in predominantly mixed failure (85%), but SBS test resulted in exclusively adhesive failure. on the effects of different surface conditioning methods, chairside and laboratory tribochemical silica coating followed by silanization showed higher bond strength results compared to those of aluminum oxide abrasion and silanization, independent of the test method employed.
Resumo:
Objectives: The objective of the present study was to evaluate a prefabricated intraradicular threaded pure titanium post, designed and developed at the Sao Jose dos Campos School of Dentistry - UNESP, Brazil. This new post was designed to minimize stresses observed with prefabricated post systems and to improve cost-benefits. Materials and and methods: Fracture resistance testing of the post/core/root complex, fracture analysis by microscopy and stress analysis by the finite element method were used for post evaluation. The following four prefabricated metal post systems were analyzed: group 1, experimental post; group 2, modification of the experimental post; group 3, Flexi Post, and group 4, Para Post. For the analysis of fracture resistance, 40 bovine teeth were randomly assigned to the four groups (n=10) and used for the fabrication of test specimens simulating the situation in the mouth. The test specimens were subjected to compressive strength testing until fracture in an EMIC universal testing machine. After fracture of the test specimens, their roots were sectioned and analyzed by microscopy. For the finite element method, specimens of the fracture resistance test were simulated by computer modeling to determine the stress distribution pattern in the post systems studied. Results: The fracture test presented the following averages and standard deviation: G1 (45.63 +/- 8.77), G2 (49.98 +/- 7.08), G3 (43.84 +/- 5.52), G4 (47.61 +/- 7.23). Stress was homogenously distributed along the body of the intraradicular post in group 1, whereas high stress concentrations in certain regions were observed in the other groups. These stress concentrations in the body of the post induced the same stress concentration in root dentin. Conclusions: The experimental post (original and modified versions) presented similar fracture resistance and better results in the stress analysis when compared with the commercial post systems tested (08/2008PA/CEP).
Resumo:
Purpose: To evaluate the effect of surface hydration state and application method on the microtensile bond strength of one-step self-etching adhesives systems to cut enamel.Materials and Methods: One hundred ninety-five bovine teeth were used. The enamel on the buccal side was flattened with 600-grit SiC paper. For the control group, 15 teeth received Adper Single Bond 2, applied according to manufacturer's recommendations. The other specimens were divided into three groups according to the adhesive system used: Futura Bond M (FM; Voco), Clearfil S-3 Bond (CS; Kuraray), and Optibond All in One (OA; Kerr). For each group, two hydration states were tested: D: blown dry with air; W: the excess of water was removed with absorbent paper. Two application methods were tested: P (passive): the adhesive was simply left on the surface; A (active): the adhesive was rubbed with an applicator point. A coat of Grandio composite resin (Voco) was applied on the surface. The teeth were sectioned to obtain enamel-resin sticks (1 x 1 mm), which underwent microtensile bond testing. The data in MPa were submitted to a three-way ANOVA and Tukey's test (alpha = 5%).Results: The ANOVA showed significant differences for application method and the type of adhesive, but not for hydration state. For the application method, the results of Tukey's test were: P: 31.46 (+/-7.09)a; A: 34.04 (+/-7.19)b. For the type of adhesive, the results were: OA: 31.29 (+/-7.05)a; CS: 32.28 (+/-7.14)a; FM: 34.68 (+/-7.17)b; different lower-case letters indicate statistically significant differences.Conclusion: Active application improved the bond strength to cut enamel. The adhesive Futurabond M showed the highest bond strength to cut enamel.
Resumo:
Indirect drug susceptibility tests of Mycobacterium tuberculosis was done to investigate the accuracy and feasibility of a broth microdilution method (BMM) for determining minimal inhibitory concentrations of conventional drugs against M. tuberculosis. Test drugs included isoniazid (H), rifampicin (R), ethambutol (E), streptomycin (S) and pyrazinamide (Z). Fifty isolates of M. tuberculosis from patients who had never received drug therapy, and H37Rv strain for control, were evaluated in the system. When comparing this method with the gold standard proportional method in Lowenstein-Jensen medium, sensitivity of 100% for all drugs and specifities of 91, 100, 96, 98 and 85% were observed respectively for H, R, E, S and Z. The BMM was read faster (14-20 days) than the proportional method (20-28 days). The microdilution method evaluated allows the testing of multiple drugs in multiple concentrations. It is easy to perform and does not require special equipment or expensive supplies. In contrast to radiometric method it does not use radioactive material.
Resumo:
A laboratory setup was designed and put into operation for the development of solid oxide fuel cells (SOFCs). The whole project consisted of the preparation of the component materials: anode, cathode and electrolyte, and the buildup of a hydrogen leaking-free sample chamber with platinum leads and current collectors for measuring the electrochemical properties of single SOFCs. Several anode-supported single SOFCs of the type (ZrO(2):Y(2)O(3)+NiO) thick anode/(ZrO(2):Y(2)O(3)) thin electrolyte/(La(0.65)Sr(0.35)MnO(3)+ZrO(2):Y(2)O(3)) thin cathode have been prepared and tested at 700 and 800 degrees C after in situ H(2) anode reduction. The main results show that the slurry-coating method resulted in single-cells with good reproducibility and reasonable performance, suggesting that this method can be considered for fabrication of SOFCs. (c) 2005 Elsevier B.V. All rights reserved.