42 resultados para test protocol
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Aim. The aim of the present study was to investigate the validity of the Lactate Minimum Test (LMT) for the determination of peak VO2 on a cycle ergometer and to determine the submaximal oxygen uptake (VO2) and pulmonary ventilation (VE) responses in an incremental exercise test when it is preceded by high intensity exercise (i.e., during a LMT).Methods. Ten trained male athletes (triathletes and cyclists) performed 2 exercise tests in random order on an electromagnetic cycle ergometer: 1) Control Test (CT): an incremental test with an initial work rate of 100 W, and with 25 W increments at 3-min intervals, until voluntary exhaustion; 2) LMT: an incremental test identical to the CT, except that it was preceded by 2 supramaximal bouts of 30-sec (similar to120% VO(2)peak) with a 30-sec rest to induce lactic acidosis. This test started 8 min after the induction of acidosis.Results. There was no significant difference in peak VO2 (65.6+/-7.4 ml.kg(-1).min(-1); 63.8+/-7.5 ml.kg(-1).min(-1) to CT and LMT, respectively). However, the maximal power output (POmax) reached was significantly higher in CT (300.6+/-15.7 W) than in the LMT (283.2+/-16.0 W).VO2 and VE were significantly increased at initial power outputs in LMT.Conclusion. Although the LMT alters the submaximal physiological responses during the incremental phase (greater initial metabolic cost), this protocol is valid to evaluate peak VO2, although the POmax reached is also reduced.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This work presents a case study on technology assessment for power quality improvement devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to validate this test protocol, the micro-DVR, a reduced power development platform for DVR (dynamic voltage restorer) devices, was tested and the results are discussed based on voltage disturbances standards. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
This work presents a case study on technology assessment for power quality devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to case test this test protocol, a development platform with reduced power for DVR (Dynamic Voltage Restorer), the Micro-DVR, was tested, and results were discussed based on voltage disturbances standards. ©2008 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Patients with Chronic Obstructive Pulmonary Disease may have muscle dysfunction, which ultimately reduce the functional capacity. Neuromuscular electrical stimulation (NMES) is a technique that can be effective in these patients, and implies low overload to the cardiorespiratory system. The aim of this study was to investigate the effects of NMES on muscle strength and cardiorespiratory fitness in COPD patients. Five patients (2 men, 3 women) were evaluated, with a mean age of 70.40 ± 6.61 years, and underwent anamnesis, anthropometric measurements, spirometry, pulmonary function, cardiopulmonary functional capacity and muscle strength in the lower limbs. After the evaluations, the patients were enrolled in a program of electrical stimulation of the quadriceps muscles, performed 3 times per week for 5 weeks. Each session lasted for 30 minutes, being reassessed at the end of the 15 sessions. Statistically significant response is observed to gain strength in lower limb (p = 0.005), but no significant responses were observed for the distance in six minute walking test before and after the test protocol for electrical stimulation. Showing that with NMES was located just gain muscle strength without effects on functional capacity, and there are few studies that investigate these effects, so further studies are needed to investigate this relationship.
Resumo:
Zagatto, AM, Padulo, J, Muller, PTG, Miyagi, WE, Malta, ES, and Papoti, M. Hyperlactemia induction modes affect the lactate minimum power and physiological responses in cycling. J Strength Cond Res 28(10): 2927-2934, 2014The aim of this study was to verify the influence of hyperlactemia and blood acidosis induction on lactate minimum intensity (LMI). Twenty recreationally trained males who were experienced in cycling (15 cyclists and 5 triathletes) participated in this study. The athletes underwent 3 lactate minimum tests on an electromagnetic cycle ergometer. The hyperlactemia induction methods used were graded exercise test (GXT), Wingate test (WAnT), and 2 consecutive Wingate tests (2 x WAnTs). The LMI at 2 x WAnTs (200.3 +/- 25.8 W) was statistically higher than the LMI at GXT (187.3 +/- 31.9 W) and WAnT (189.8 +/- 26.0 W), with similar findings for blood lactate, oxygen uptake, and pulmonary ventilation at LMI. The venous pH after 2 x WAnTs was lower (7.04 +/- 0.24) than in (p <= 0.05) the GXT (7.19 +/- 0.05) and WAnT (7.19 +/- 0.05), whereas the blood lactate response was higher. In addition, similar findings were observed for bicarbonate concentration [HCO3] (2 x WAnTs lower than WAnT; 15.3 +/- 2.6 mmol center dot L-1 and 18.2 +/- 2.7 mmol center dot L(-)1, respectively) (p <= 0.05). However, the maximal aerobic power and total time measured during the incremental phase also did not differ. Therefore, we can conclude that the induction mode significantly affects pH, blood lactate, and [HCO3] and consequently they alter the LMI and physiological parameters at LMI.
Resumo:
Pós-graduação em Desenvolvimento Humano e Tecnologias - IBRC
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Background: Obstructive sleep apnea (OSA) is a respiratory disease characterized by the collapse of the extrathoracic airway and has important social implications related to accidents and cardiovascular risk. The main objective of the present study was to investigate whether the drop in expiratory flow and the volume expired in 0.2 s during the application of negative expiratory pressure (NEP) are associated with the presence and severity of OSA in a population of professional interstate bus drivers who travel medium and long distances.Methods/Design: An observational, analytic study will be carried out involving adult male subjects of an interstate bus company. Those who agree to participate will undergo a detailed patient history, physical examination involving determination of blood pressure, anthropometric data, circumference measurements (hips, waist and neck), tonsils and Mallampati index. Moreover, specific questionnaires addressing sleep apnea and excessive daytime sleepiness will be administered. Data acquisition will be completely anonymous. Following the medical examination, the participants will perform a spirometry, NEP test and standard overnight polysomnography. The NEP test is performed through the administration of negative pressure at the mouth during expiration. This is a practical test performed while awake and requires little cooperation from the subject. In the absence of expiratory flow limitation, the increase in the pressure gradient between the alveoli and open upper airway caused by NEP results in an increase in expiratory flow.Discussion: Despite the abundance of scientific evidence, OSA is still underdiagnosed in the general population. In addition, diagnostic procedures are expensive, and predictive criteria are still unsatisfactory. Because increased upper airway collapsibility is one of the main determinants of OSA, the response to the application of NEP could be a predictor of this disorder. With the enrollment of this study protocol, the expectation is to encounter predictive NEP values for different degrees of OSA in order to contribute toward an early diagnosis of this condition and reduce its impact and complications among commercial interstate bus drivers.
Resumo:
We propose a new protocol intended to conform to the 3Rs (replacement, reduction, and refinement) principle, using animals fasted for 3 h to control intestinal motility, which reduced stress in the animals. In this new protocol, mice are deprived of food for a short time (3 h) and are not killed. The mice are observed until evacuation containing charcoal is observed, and the experimental results are based on the charcoal evacuation time. The present study may aid the formulation of recommendations that can be included in revised guidelines relating to the fasting time of mice. This new concept of an intestinal motility test conforms with respectful science.
Resumo:
The purpose of this study was to validate the lactate minimum test as a specific aerobic evaluation protocol for table tennis players. Using the frequency of 72 balls·min-1 for 90 sec, an exercise-induced metabolic acidosis was determined in 8 male table tennis players. The evaluation protocol began with a frequency of 40 balls·min-1 followed by an increase of 8 balls·min-1 every 3 min until exhaustion. The mean values that corresponded to the subjects' lactate minimum (Lacmin) were equal to 53.1 ± 1.5 balls·min-1 [adjusted for the time test (Lacmin_time)] and 51.6 ± 1.6 balls·min-1 [adjusted for the frequency of balls (Lacmin_Freq)], which resulted in a high correlation between the two forms of adjustment (r = 0.96 and (P = 0.01). The mean maximum lactate steady state (MLSS) was 52.6 ± 1.6 balls·min-1. Pearson's correlations between Lacmin_time vs. MLSS and Lacmin_freq vs. MLSS were statistically significant (P = 0.03 and r = 0.86, P = 0.03 and r = 0.85, respectively). These findings indicate that the Lacmin test predicts MLSS. Therefore, it is an excellent method to obtain the athletes' anaerobic threshold. Also, there is the advantage that it can be performed in 1 day in the game area. However, the Lacmin value does not depend on the Lacpeak value.
Resumo:
OBJETIVO: Determinar a acurácia das variáveis: tempo de escada (tTE), potência de escada (PTE), teste de caminhada (TC6) e volume expiratório forçado (VEF1) utilizando o consumo máximo de oxigênio (VO2máx) como padrão-ouro. MÉTODOS: Os testes foram realizados em 51 pacientes. O VEF1 foi obtido através da espirometria. O TC6 foi realizado em corredor plano de 120m. O TE foi realizado em escada de 6 lances obtendo-se tTE e PTE. O VO2máx foi obtido por ergoespirometria, utilizando o protocolo de Balke. Foram calculados a correlação linear de Pearson (r) e os valores de p, entre VO2máx e variáveis. Para o cálculo da acurácia, foram obtidos os pontos de corte, através da curva característica operacional (ROC). A estatística Kappa (k) foi utilizada para cálculo da concordância. RESULTADOS: Obteve-se as acurácias: tTE - 86%, TC6 - 80%, PTE - 71%, VEF1(L) - 67%, VEF1% - 63%. Para o tTE e TC6 combinados em paralelo, obteve-se sensibilidade de 93,5% e em série, especificidade de 96,4%. CONCLUSÃO: O tTE foi a variável que apresentou a melhor acurácia. Quando combinados o tTE e TC6 podem ter especificidade e sensibilidade próxima de 100%. Estes testes deveriam ser mais usados rotineiramente, especialmente quando a ergoespirometria para a medida de VO2máx não é disponível.
Resumo:
CONTEXTO E OBJETIVO: A falta de consenso sobre os protocolos de rastreamento e diagnóstico do diabetes gestacional, associada às dificuldades na realização do teste oral simplificado do diabete gestacional (o teste de tolerância a 100 g de glicose, considerado padrão-ouro) justificam a comparação com alternativas. O objetivo deste trabalho é comparar o teste padrão-ouro a dois testes de rastreamento: associação de glicemia de jejum e fatores de risco (GJ + FR) e o teste oral simplificado de tolerância a 50 g de glicose (TTG 50 g), com o teste de tolerância a 100 g de glicose (TTG 100 g). TIPO DE ESTUDO E LOCAL: Estudo de coorte longitudinal, prospectivo, realizado no Serviço de Ginecologia e Obstetrícia do Hospital Universitário da Universidade Federal de Mato Grosso do Sul. MÉTODOS: 341 gestantes foram submetidas aos três testes. Calcularam-se os índices de sensibilidade (S), especificidade (E), valores preditivos (VPP e VPN), razões de probabilidade (RPP e RPN) e resultados falsos (FP e FN), positivos e negativos da associação GJ + FR e do TTG 50 g em relação ao TTG 100 g. Compararam-se as médias das glicemias de uma hora pós-sobrecarga (1hPS) com 50 e 100 g. Na análise estatística, empregou-se o teste t de Student, com limite de significância de 5%. RESULTADOS: A associação GJ + FR encaminhou mais gestantes (53,9%) para a confirmação diagnóstica que o TTG 50 g (14,4%). Os dois testes foram equivalentes nos índices de S (86,4 e 76,9%), VPN (98,7 e 98,9%), RPN (0,3 e 0,27) e FN (15,4 e 23,1%). As médias das glicemias 1hPS foram semelhantes, 106,8 mg/dl para o TTG 50 g e 107,5 mg/dl para o TTG 100 g. CONCLUSÕES: Os resultados da eficiência diagnóstica associados à simplicidade, praticabilidade e custo referendaram a associação GJ + FR como o mais adequado para o rastreamento. A equivalência das glicemias de 1hPS permitiram a proposição de um novo protocolo de rastreamento e diagnóstico do diabete gestacional, com menores custo e desconforto.
Resumo:
The objectives of the present study were to optimize the protocol of mouse immunization with Paracoccidioides brasiliensis antigens (Rifkind's protocol) and to test the modulation effect of cyclophosphamide (Cy) on the delayed hypersensitivity response (DHR) of immunized animals. Experiments were carried out using one to four immunizing doses of either crude particulate P. brasiliensis antigen or yeast-cell antigen, followed by DHR test four or seven days after the last immunizing dose. The data demonstrated that an immunizing dose already elicited response; higher DHR indices were obtained with two or three immunizing doses; there were no differences between DHR indices of animals challenged four or seven days after the last dose. Overall the inoculation of two or three doses of the yeast-cell antigen, which is easier to prepare, and DHR test at day 4 simplify the original Rifkind's immunization protocol and shorten the duration of the experiments. The modulation effect of Cy on DHR was assayed with administration of 2.5, 20 and 100 mg/kg weight at seven day intervals starting from day 4 prior to the first immunizing dose. Only the treatment with 2.5 mg Cy increased the DHR indices. Treatment with 100 mg Cy inhibited the DHR, whereas 20 mg Cy did not affect the DHR indices. Results suggest an immunostimulating effect of low dose of Cy on the DHR of mice immunized with P. brasiliensis antigens.