77 resultados para system analysis

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dynamical system investigated in this work is a nonlinear flexible beam-like structure in slewing motion. Non-dimensional and perturbed governing equations of motion are presented. The analytical solution for the linear part of these perturbed equations for ideal and for non-ideal cases are obtained. This solution is necessary for the investigation of the complete weak nonlinear problem where all nonlinearities are small perturbations around a linear known solution. This investigation shall help the analyst in the modelling of dynamical systems with structure- actuator interactions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article shows an analysis of the longitudinal electric parameters of a three-phase transmission line/section using a 280-meter high steel tower. This characteristic, the height of the line conductors and distance between them, are intrinsic related to the longitudinal and transversal parameters of the line. By this means, an accurate study was carried out in order to show the electric variations between a transmission line using the new technology and a three-phase conventional 440 kV line for a wide range of frequencies and a variable soil resistivity. In addition, by using a digital line model, simulations are carried out in time domain to analyze critical overvoltage transients on the studied line. © 2011 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CONTEXTUALIZAÇÃO: O teste de capacidade vital forçada (CVF) é rotineiramente realizado na avaliação da função pulmonar de pacientes com doença pulmonar obstrutiva crônica (DPOC). Entretanto, permanece pouco compreendida a influência do teste de CVF sobre o sistema cardiovascular de pacientes com DPOC. OBJETIVOS: Analisar o comportamento da frequência cardíaca (FC), pressão arterial (PA) e variabilidade da frequência cardíaca (VFC) no teste de CVF na DPOC. MÉTODOS: Dezenove homens com DPOC (72 ± 7 anos, no estágio de gravidade GOLD I=3, II=5, III=7 e IV=4 pacientes) realizaram a manobra de CVF e tiveram sua FC monitorada durante todo o exame, e a VFC analisada nos domínios do tempo (rMSSD) e da frequência (BF, AF e BF/AF) durante o repouso, antes e após a melhor manobra de CVF. A PA foi analisada no repouso, imediatamente ao final da manobra de CVF e 10 minutos após o término de todos os testes. RESULTADOS: Ao início da manobra de CVF, a FC reduziu (p<0,001) e, em seguida, aumentou progressivamente até o final do teste (p<0,001). Após término da manobra, a FC continuou a aumentar até atingir um pico (p<0,001) e depois caiu rapidamente a valores inferiores aos de repouso (p<0,001) e retornou ao seu valor basal. A PA e os índices da VFC não sofreram alterações nos períodos analisados. CONCLUSÃO: O teste de CVF influencia o comportamento da FC, sem alterar o seu controle autonômico, bem como a PA em pacientes com DPOC nos períodos analisados.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Research of advanced technologies for energy generation contemplates a series of alternatives that are introduced both in the investigation of new energy sources and in the improvement and/or development of new components and systems. Even though significant reductions are observed in the amount of emissions, the proposed alternatives require the use of exhaust gases cleaning systems. The results of environmental analyses based on two configurations proposed for urban waste incineration are presented in this paper; the annexation of integer (Boolean) variables to the environomic model makes it possible to define the best gas cleaning routes based on exergetic cost minimisation criteria. In this first part, the results for steam cogeneration system analysis associated with the incineration of municipal solid wastes (MSW) is presented. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, a multi-objective approach for observing the performance of distribution systems with embedded generators in the steady state, based on heuristic and power system analysis, is proposed. The proposed hybrid performance index describes the quality of the operating state in each considered distribution network configuration. In order to represent the system state, the loss allocation in the distribution systems, based on the Z-bus loss allocation method and compensation-based power flow algorithm, is determined. Also, an investigation of the impact of the integration of embedded generators on the overall performance of the distribution systems in the steady state, is performed. Results obtained from several case studies are presented and discussed. Copyright (C) 2004 John Wiley Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The root-locus method is a well-known and commonly used tool in control system analysis and design. It is an important topic in introductory undergraduate engineering control disciplines. Although complementary root locus (plant with negative gain) is not as common as root locus (plant with positive gain) and in many introductory textbooks for control systems is not presented, it has been shown a valuable tool in control system design. This paper shows that complementary root locus can be plotted using only the well-known construction rules to plot root locus. It can offer for the students a better comprehension on this subject. These results present a procedure to avoid problems that appear in root-locus plots for plants with the same number of poles and zeros.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main goal of this study was to identify and analyse environmental problems related to human occupation at the south part of the city of Paranagua PR, Brazil, aiming the diagnosis and conceptual evaluation of landscape use. For landscape use assessments and degradation diagnosis purposes, the environment was classified considering mainly geological and geomorphologic characteristics, such as declivity and sediment origin. The identification of potential environmental impacts was made by aerial photographs, Landsat-TM images, photographic records, surface sediment samples, water-column samples, and mainly observation visits to each classified unit. Surface sediment samples were taken with a Petit-Ponar sampler, in 13 station located in Paranagua Bay. In order to characterize the contamination level on sediments, the concentration of the following elements were analysed: arsenic (As), copper (Cu), cadmium (Cd), nickel (Ni), lead (Ph) e zinc (Zn). For the extraction of these elements, samples were treated with HCl 0.1N for 12 hours. This method has the advantage of determining contaminants which are weakly bind to the sediment, thus more available to the system. Analysis were performed by atomic absorption spectroscopy. According to the adopted criteria, sectors were classified as hills, mangroves, continental sediments and beach ridges urban and port industrial. Water quality and concentrations of metallic elements were determined at three sectors one control and two with the influence of urban and port/industrial activities, respectively the major upland impacts found were: deforestation due to disordered occupation, and solid waste emission through domestic and industrial sewage. The diagnosis of the actual situation was used as a basis for a management plan, once it allows the identification of impacts, and consequent environmental irregularities. Based on this considerations, suggestions for land use and management were presented, which offers a better approach for recuperation and protection of the studied ecosystem.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents the design and procedure of a DC-to-AC converter using a ZVS Commutation Cell developed by Barbi and Martins (1991) and applied to the family of DC-to-DC PWM converters. Firstly, we show the cell applied to buck converter. The stages of operation and the main current and voltage equations of the resonant devices are presented. Next, we adapt the converter to the regenerative operation mode. Hence, the full bridge converter at low frequency operation is conected on the DC-to-DC stage (at high frequency) output ends (Seixas, 1993). Commutation of zero voltage for all switches, PWM at constant frequency and neither overvoltage nor additional current stress are observed by digital simulation. The design example and experimental results obtained by prototype rated at 275 V, 1 kW and 40 kHz are also presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper addresses the problem of model reduction for uncertain discrete-time systems with convex bounded (polytope type) uncertainty. A reduced order precisely known model is obtained in such a way that the H2 and/or the H∞ guaranteed norm of the error between the original (uncertain) system and the reduced one is minimized. The optimization problems are formulated in terms of coupled (non-convex) LMIs - Linear Matrix Inequalities, being solved through iterative algorithms. Examples illustrate the results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Bose-Einstein correlations are studied in semileptonic (WW → qq̄lv) and fully hadronic (WW → qq̄qq̄) W-pair decays with the ALEPH detector at LEP at centre-of-mass energies of 172, 183 and 189 GeV. They are compared with those made at the Z peak after correction for the different flavour compositions. A Monte Carlo model of Bose-Einstein correlations based on the JETSET hadronization scheme was tuned to the Z data and reproduces the correlations in the WW → qq̄lv events. The same Monte Carlo reproduces the correlations in the WW → qq̄qq̄ channel assuming independent fragmentation of the two W's. A variant of this model with Bose-Einstein correlations between decay products of different W's is disfavoured. (C) 2000 Published by Elsevier Science B.V.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Relaxed conditions for the stability study of nonlinear, continuous and discrete-time systems given by fuzzy models are presented. A theoretical analysis shows that the proposed method provides better or at least the same results of the methods presented in the literature. Digital simulations exemplify this fact. These results are also used for the fuzzy regulators design. The nonlinear systems are represented by the fuzzy models proposed by Takagi and Sugeno. The stability analysis and the design of controllers are described by LMIs (Linear Matrix Inequalities), that can be solved efficiently by convex programming techniques. The specification of the decay rate, constraints on control input and output are also described by LMIs. Finally, the proposed design method is applied in the control of an inverted pendulum.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article addresses the problem of stability of impulsive control systems whose dynamics are given by measure driven differential inclusions. One important feature concerns the adopted solution which allows the consideration of systems whose singular dynamics do not satisfy the so-called Frobenius condition. After extending the conventional notion of control Lyapounov pair for impulsive systems, some stability conditions of the Lyapounov type are given. Some conclusions follow the outline of the proof of the main result.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A systematic procedure of zero placement to design control systems is proposed. A state feedback controller with vector gain K is used to perform the pole placement. An estimator with vector gain L is also designed for output feedback control. A new systematic method of zero assignment to reduce the effect of the undesirable poles of the plant and also to increase the velocity error constant is presented. The methodology places the zeros in a specific region and it is based on Linear Matrix Inequalities (LMIs) framework, which is a new approach to solve this problem. Three examples illustrate the effectiveness of the proposed method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, a methodology based on Unconstrained Binary Programming (UBP) model and Genetic Algorithms (GAs) is proposed for estimating fault sections in automated distribution substations. The UBP model, established by using the parsimonious set covering theory, looks for the match between the relays' protective alarms informed by the SCADA system and their expected states. The GA is developed to minimize the UBP model and estimate the fault sections in a swift and reliable manner. The proposed methodology is tested by utilizing a real-life automated distribution substation. Control parameters of the GA are tuned to achieve maximum computational efficiency and reduction of processing time. Results show the potential and efficiency of the methodology for estimating fault section in real-time at Distribution Control Centers. ©2009 IEEE.