31 resultados para surface electromyography
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: To measure and compare the activity of the masseter, temporalis and buccinator muscles in different infant feeding methods. Method: Cross-sectional study of 60 full-term infants with no intercurrent diseases, aged between two and three months, classified into the following groups: 1) exclusive breastfeeding; 2) breastfeeding plus bottle-feeding; and 3) exclusive breastfeeding plus cup feeding. Surface electromyography was performed during infant feeding. The Krushal-Wallis test was used, complemented by multiple paired comparisons of the groups. A 5% significance level was chosen for the tests. Results: Statistically higher results were verified in the breastfeeding group in relation to the bottle-feeding one, both in the range of movement and the mean contraction of the masseter. With regard to the temporalis muscle, statistically higher results were found in the breastfeeding group comparatively to the bottle-feeding one. As to the buccinator muscle, statistically higher results were observed in the breastfeeding group in relation to the bottle-feeding one, although in this case, the difference concerned only the range of contraction. Conclusion: The similarities between the muscle activity in the breastfeeding and in the cup-feeding groups suggests that cup-feeding can be used as an alternative infant feeding method, being better than bottle-feeding, due to the hyperactivity of the buccinator muscle, which could result in changes to the structural growth and development of the stomatognathic system functions. Copyright © 2006 by Sociedade Brasileira de Pediatria.
Resumo:
The advancement of knowledge in neurophysiology has demonstrated that acupuncture is a method of peripheral neural stimulation that promotes local and systemic reflexive responses. The purpose of this study was to determine if surface electromyography can be used as a tool to study the action of auricular acupuncture on striated skeletal muscle. The electromyographic amplitudes of the anterior, middle and posterior deltoid muscle and the upper trapezium muscle with 20%, 40% and 60% of maximal voluntary contraction of 15 healthy volunteers, were analyzed after the individuals were submitted to the auricular acupuncture treatment. The non-parametric Friedman test was used to compare Root Mean Square values estimated by using a 200 ms moving window. Significant results were further analyzed using the Wilcoxon signed rank test. In this exploratory study, the level of significance of each comparison was set to p < 0.05. It was concluded in this study that a surface electromyography can be used as a tool to investigate possible alterations of electrical activity in muscles after auricular acupuncture. However there is still a lack of adequate methodology for its use in this type of study, being that the method used to record the electromyographic signal can also influence the results. © 2008 Elsevier Ltd. All rights reserved.
Resumo:
The use of low-level laser (LLL) may be an useful tool to promote reduction of muscular pain caused by TMD. Aim: This study evaluated the immediate efficacy of low-level laser therapy on women reporting pain and diagnosed with temporomandibular dysfunction (TMD). Methods: Diode laser (GaAlAs) at 790 nm wavelength (infrared spectrum) was applied as experimental treatment. Irradiations of 1.5 J/cm2 were made at 4 points of the temporomandibular joint (TMJ) and of 3 J/cm2 at 3 points in the temporal muscle. An electromyographic (EMG) evaluation of the masseter and anterior temporal was done at the following intervals: before, immediately after, 5 min and 20 min after laser application. Results: Comparison of the electrical activity at the times of measurement revealed a statistically significant difference in masseter muscles before (P=0.025) and immediately after (P=0.013) LLLT. Conclusions: Both masseter and temporal muscles showed a reduction in the measured EMG activities at all times after LLLT, and the temporal muscle showed higher EMG activity than the masseter muscle at all the evaluation times. LLLT caused significant immediate relaxation of the masseter muscles.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Despite its high incidence, patellofemoral pain etiology remains unclear. No prior study has compared surface electromyography frequency domain parameters and surface electromyography time domain variables, which have been used as a classic analysis of patellofemoral pain. Thirty one women with patellofemoral pain and twenty eight pain-free women were recruited. Each participant was asked to descend a seven step staircase and data from five successful trials were collected. During the task, the vastus medialis and vastus lateralis muscle activities were monitored by surface electromyography. The data were processed and analyzed in four variables of the frequency domain (median frequency, low, medium and high frequency bands) and three time domain variables (Automatic, Cross-correlation and Visual Onset between the vastus medialis and vastus lateralis muscles). Reliability, Receiver Operating Characteristic curves and regression models were performed. The medium frequency band was the most reliable variable and different between the groups for both muscles, also demonstrated the best values of sensitivity and sensibility, 72% and 69% for the vastus medialis and 68% and 62% for the vastus lateralis, respectively. The frequency variables predicted the pain of individuals with patellofemoral pain, 26% for the vastus medialis and 20% for the vastus lateralis, being better than the time variables, which achieved only 7%. The frequency domain parameters presented greater reliability, diagnostic accuracy and capacity to predict pain than the time domain variables during stair descent and might be a useful tool to diagnose individuals with patellofemoral pain.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: investigar as diferenças entre os achados eletromiográficos dos músculos supra-hióideos direito e esquerdo durante a deglutição de um líquido e um pastoso fino, em sujeitos idosos com doença de Parkinson e idosos sem doença neurológica. MÉTODOS: 30 sujeitos de ambos os sexos participaram deste estudo, 15 idosos sem doença neurológica e os demais com doença de Parkinson. Todos foram submetidos a um protocolo de avaliação clínica e avaliação eletromiográfica de superfície. RESULTADOS: foram constatadas diferenças significantes nos valores entre os sujeitos (f=14.4 e p= 0.000) e entre os lados (f=4.4 e p=0.0037). em relação ao tempo de duração da contração muscular durante a deglutição as diferenças foram significantes apenas entre as consistências (f=8.2 e p=0.005). CONCLUSÃO: a amplitude eletromiográfica foi menor nos sujeitos com doença de Parkinson e maior nos músculos supra-hiódeos do lado direito em ambos os grupos. A duração da contração muscular não diferiu significativamente entre os sujeitos com doença de Parkinson e idosos sem doença neurológica e foi menor para a consistência líquida.
Resumo:
Background: The literature reports that the eccentric muscular action produces greater force and lower myoelectric activity than the concentric muscular action, while the heart rate (HR) responses are bigger during concentric contraction. Objectives: To investigate the maximum average torque (MAT), surface electromyographic (SEMG) and the heart rate (HR) responses during different types of muscular contraction and angular velocities in older men. Methods: Twelve healthy men (61.7 +/- 1.6years) performed concentric (C) and eccentric (E) isokinetic knee extension-flexion at 60 degrees/s and 120 degrees/s. SEMG activity was recorded from vastus lateralis muscle and normalized by Root Mean Square-RMS (mu V) of maximal isometric knee extension at 60 degrees. HR (beats/min) and was recorded at rest and throughout each contraction. The data were analyzed by the Friedman test for repeated measures with post hoc Dunn's test (p<0.05). Results: The median values of MAT (N.m/kg) was smaller and the RMS (mu V) was larger during concentric contraction (C60 degrees/s=2.80 and 0.99; C120 degrees/s=2.46 and 1.0) than eccentric (E60 degrees/s=3.94 and 0.85; E120 degrees/s=4.08 and 0.89), respectively. The HR variation was similar in the four conditions studied. Conclusion: The magnitude of MAT and RMS responses in older men were dependent of the nature of the muscular action and independent of the angular velocity, whereas HR response was not influenced by these factors.
Resumo:
It was purposed the use of electromyography (EMG) to evaluate the activation of the agonists and antagonists muscles of spastic patients, to test the viability in the development of an instrument that given quantitative data of the patient spasticity. 30 hemiplegic and 15 normal volunteers had been submitted to the EMG of flexor and extensor carpi ulnaris muscles during the flexion and extension movements of the wrist. The individuals with less severe spasticity (mAS (modified Ashworth Scale) ringing 0 to 3 degree), had presented deficit in the activation of the flexor muscles in plegic side in relation to the non plegic side and that the individuals seriously compromised by the spasticity (mAS = 4 degree) present deficit of reciprocal inhibition. One evidenced is that the non plegic member does not present a similar neuro-motor comportment when compared to the normal member. The surface electromyography is a practical clinical instrument to evaluate the patient with spasticity and the hemiplegic patient needs to be evaluated on both sides (deficient and no deficient) because the no compromised side do not show a normality standard.
Resumo:
The effects of occlusal splint on the electric activity of masseter were studied in 15 women who presented sleep bruxism using surface electromyography. Sleep bruxism was defined by its clinical characteristics. The signal acquisition was done during mandible occlusion without clenching and maximum voluntary contraction in two situations. The first was after a workday without using the occlusal splint; and the second, after a sleeping night using occlusal splints. Evaluating masseter muscles during mandible occlusion without clenching, it could be observed that lower values were noticed after splint wearing in both sides. The same results were verified in maximum voluntary contraction (MVC). These results confirmed that the use of occlusal splints reduced the electromyographic activity of the right and left masseters, showing its myorelaxing effect. © 2009 Elsevier Ltd. All rights reserved.
Resumo:
Bruxism is widely defined as an anxiety response to environmental stress. Occlusal splints are frequently used in sleep bruxism, to protect teeth from damage resulting from the contraction force of mandibular muscles, or to reduce the orofacial pain by relaxing masticatory muscles. Surface electromyography (EMG) of the right and left masseter and temporalis muscles was performed in 15 women presenting sleep bruxism and temporomandibular disorders related to occupational stress, after nocturnal use of the occlusal splint. The EMG signals were recorded twice per patient: After a work shift (pre-splint) and after a night of sleep with the occlusal splint (post-splint) before a new workday. The parametric t-paired test was used to compare differences of the RMS amplitude between pre and post-splint records, for resting and maximal clenching effort. The level of significance for each comparison was set to p < 0.05. The results of the study supports the premise that the use of occlusal splint reduces EMG activity in the masseter and anterior temporalis muscles, in patients who presented with sleep bruxism related to occupational stress. © 2011 Elsevier Ltd.
Resumo:
Fragile X syndrome is a cytogenetic abnormality related to chromosomal X. This syndrome is frequently associated to intellectual disability, psychological problems, as well as heart, skeletal and join alterations. Intraoral anomalies include malloclusion, ogival palate, cleft palate, presence of mesiodens, dental hypomineralization and abrasion of the occlusal surfaces and incisai edges. The study of characteristics of this syndrome is important for the dentist in order to guide dental treatment and prevention. The aim of this study is to present a myofunctional therapy protocol, evaluated by surface electromyography. A case of a 21 year-old young man who attended the Training Program in Dentistry for Persons with Disabilities, School of Dentistry of São José dos Campos/UNESP is reported. He underwent myofunctional therapy before dental treatment and the masticatory muscles were evaluated by surface electromyography. The exercises of myofunctional therapy consisted of active and passive simple movements of opening and closing the mouth, tongue protrusion and retrusion, digital manipulation and also by using an electric massager on intraoral and perioral region of the masseter, buccinator and orbicularis oris. Action potentials of the masticatory muscles decreased in almost all the muscles and values for the bite force and mandibular opening capacity increased. This study showed that brief and immediate myofunctional therapy optimized clinical practice with positive repercussion on dental care.
Resumo:
Introduction. Studies show that 70% of body weight in patients with stroke during the transfer from sitting to standing position is transferred to the uninvolved limb. Significantly interfering with activities of daily living. Objective. The influence of aquatic therapy on eight in the affected hemisphere during the transition from sitting to standing. Method. Participated in this study a patient with right hemiparesis, the protocol lasted eight sessions in a liquid medium. The data of activation of the gluteus muscle were collected from surface electromyography and data as the weight transfer was examined by baropodometry platform. Results. Initial electromyography (151.1uv right gluteus maximus and left gluteus maximus 229.1uv) and Final electromyography (113.6 uv right gluteus maximus and left gluteus maximus113.3uv). Evolution was 19% in weight transferin paretic hemibody compared the pre and post intervention. Conclusion. The results showed that treatment was favorable to the patient, because at the end of application of the observed activation of the gluteus maximus and improved weight-bearing, and consequently these factors interfered positively in the security and independe in transferring from sitting to standing position.