70 resultados para subtraction
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Objective: The objective of this study was to evaluate the influence of homeopathic treatment with comfrey (Shymphytum officinalis 6CH) on radiographic bone density and area around titanium implants.Material and methods: Forty-eight rats were divided into two groups of 24 animals each: a control group (C) and a test group (SO). Each animal received one titanium micro-implant placed in the tibia. The animals in Group SO were subjected to 10 drops of comfrey 6CH per day mixed into their drinking water until the day of sacrifice. Eight animals of each group were sacrificed at 7, 14 and 28 days post-surgery, respectively.Standardized digital radiographs were obtained on the day of implant installation (baseline images) and on the day of sacrifice (final images). Digital subtraction of the two corresponding images was performed to evaluate changes in bone density and the area related to change around the implant between baseline and final images.Results: Subtraction images demonstrated that a significant difference existed in mean shade of gray at 14 days post-surgery between Group SO (mean 175.3 +/- 14.4) and Group C (mean 146.2 +/- 5.2). Regarding the area in pixels corresponding to the bone gain in Group SO, the differences observed between the sacrifice periods and groups were only significant at 7 days sacrifice between Group SO (mean 171.2 +/- 21.9) and Group C (mean 64.5 +/- 60.4).Conclusion: Within the limits of this study, comfrey administration promotes an increase in radiographic bone density around titanium implants in the initial period of bone healing.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to describe a new technique by using Adobe Photoshop CS (San Jose, CA) image-analysis software to evaluate the radiographic changes of chronic periapical lesions after root canal treatment by digital subtraction radiography. Thirteen upper anterior human teeth with pulp necrosis and radiographic image of chronic periapical lesion were endodontically treated and radiographed 0, 2, 4, and 6 months after root canal treatment by using a film holder. The radiographic films were automatically developed and digitized. The radiographic images taken 0, 2, 4, and 6 months after root canal therapy were submitted to digital subtraction in pairs (0 and 2 months, 2 and 4 months, and 4 and 6 months) choosing image, calculation, subtract, and new document tools from Adobe Photoshop CS image-analysis software toolbar. The resulting images showed areas of periapical healing in all cases. According to this methodology, the healing or expansion of periapical lesions can be evaluated by means of digital subtraction radiography by using Adobe Photoshop CS software.
Resumo:
Objectives: The aim of this study was to compare two methods for the evaluation of periapical lesion changes following endodontic therapy (digital subtraction technique and morphometric analysis) by outlining the radiolucent area.Methods: 13 human anterior teeth with pulp necrosis and chronic periapical lesions were used. Periapical radiographs were taken immediately after endodontic therapy (0) and then 2 months, 4 months and 6 months post treatment, using an intraoral radiographic film holder stabilized with impression material. The films were processed in a standard manner and the digitized images were submitted to digital subtraction using Adobe Photoshop 6.0. New bone formation or bone resorption areas were then measured. In the morphometric analysis, the periapical lesions were outlined using VixWin 2000 and the area (in square millimetres) was recorded. The obtained data were submitted to agreement analysis for comparison of the two techniques.Results: There was no correlation between the areas of radiographic changes detected by digital subtraction and periapical lesion outline (r=0.02-0.45). The new bone formation areas observed by digital subtraction presented higher values, with bone changes being especially evident in the 2 month follow-up radiographs, which suggests a higher sensitivity for this method.Conclusions: Both methods are suitable for the evaluation of periapical lesion changes, but the digital subtraction technique is more sensitive for detecting radiographic periapical changes. Dentomaxillofacial Radiology (2009) 38, 438-444. doi: 10.1259/dmfr/53304677
Resumo:
Introduction: Root resorption can cause damage in orthodontic patients. Digital subtraction radiography (DSR) is a useful resource for the detection of mineral losses. The purpose of this study was to compare the efficacy of digital radiography (DR) and DSR in detecting simulated external root resorption. Examiner agreement between the 2 techniques was also evaluated. Methods: Root resorptions of various sizes were simulated on the apical and lingual aspects of 49 teeth from 9 dry human mandibles. The teeth were radiographed in standardized conditions. The radiographs were registered with Regeemy Image Registration and Mosaicking (version 0.2.43-RCB, DPI-INPE, Sao Jose dos Campos, São Paulo, Brazil) and subtracted with Image Tool (University of Texas Health Science Center at San Antonio). The subtracted images and the digital radiographs were evaluated by 3 oral radiologists. Results: No statistically significant differences were found for the methods in the detection of apical root resorptions, independently from lesion size, and of lingual resorptions of 1.2 mm or greater. DSR was significantly better than DR for detection of lingual resorptions up to 1 mm. Resorptions less than 0.5 mm were not precisely detected by either method. DSR provided better intraexaminer and interexaminer agreement than did DR. Conclusions: Both methods are precise for detection of apical root resorptions as small as 0.5 mm and lingual resorptions of 1 mm or more. However, DSR frequently performed better than did DR. (Am J Orthod Dentofacial Orthop 2011;139:324-33)
Resumo:
Introduction: The aim of this study was to assess the occurrence of apical root transportation after the use of Pro Taper Universal rotary files sizes 3 (F3) and 4 (F4). Methods: Instruments were worked to the apex of the original canal, always by the same operator. Digital subtraction radiography images were produced in buccolingual and mesiodistal projections. A total of 25 radiographs were taken from root canals of human maxillary first molars with curvatures varying from 23-31 degrees. Quantitative data were analyzed by intraclass correlation coefficient and Wilcoxon nonparametric test (P = .05). Results: Buccolingual images revealed a significantly higher degree of apical transportation associated with F4 instruments when compared with F3 instruments in relation to the original canal (Wilcoxon test, P = .007). No significant difference was observed in mesiodistal images (P = .492). Conclusions: F3 instruments should be used with care in curved canals, and F4 instruments should be avoided in apical third preparation of curved canals. (J Endod 2010;36:1052-1055)
Resumo:
Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to 'detect occlusal caries.Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site.Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy far the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly.Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the Sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure.Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.
Resumo:
The in vitro gas production of four single roughages and their paired combinations (1:1 on dry matter basis) were evaluated. Two roughage samples (100 mg) per treatment were fermented with ruminal fluid during a 48 h incubation period. Total 48 h gas volumes of fermentation dry matter (DM), neutral detergent fiber (NDF) and soluble compounds in neutral detergent (NDS) were for sugarcane = 16.8, 11.2, 6.9 mL; sugarcane + corn silage = 20.1, 12.6, 9.1 mL; sugarcane + 60-day elephantgrass = 16.5, 17.6 mL; sugarcane + 180-day elephantgrass = 13.8, 8.2, 5.9 mL; corn silage = 18.8, 16.8, 4.7 mL; corn silage + 60-day elephantgrass = 16.3, 15.4, 2.4 mL; corn silage + 180-day elephantgrass = 16.1, 11.8, 4.2 mL; 60-day elephantgrass = 16.9, 19.0 mL and 180-day elephantgrass = fermented 10.7, 12.2 mL, respectively. The NDS gas production was not possible to estimate for sugarcane + 60-day elephantgrass, 60-day elephantgrass and 180-day elephantgrass. The present data shows that the curves subtraction method can be an option to evaluate the contribution of the soluble fractions in roughages to digestion kinetics. However, this method underestimates the NDS gas contribution when roughages are low in crude protein and soluble carbohydrates. It is advisable to directly apply the two-compartmental mathematical model to the digestion curves for roughage DM, when determining the NDS gas volume and the digestion rate. This method is more straightforward and accurate when compared to the curve subtraction method. Non-structural carbohydrates combined with fiber and protein promoted a positive associative effect in sugarcane + corn silage (50:50) mixture. Therefore, it can be concluded that the soluble fraction of roughages greatly contributes to gas production. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.
Resumo:
The aim of this paper was to report the diagnosis and evaluation of periradicular bone repair by using computed tomography and digital subtraction radiography in an endodontic surgery case treated with mineral trioxide aggregate (MTA). The patient had local swelling and fistula 7years after trauma in the upper jaw. Periapical lesion on tooth #12 and root resorption of tooth #11 were detected radiographically. Endodontic therapy and placement of intracanal medication were carried out. After 3months, with no improvement in the clinical signs and symptoms, computed tomography was performed, showing extensive apical bone resorption on tooth #12 and dental resorption promoting communication of the root canal with the periodontium of tooth #11. The patient was referred to endodontic surgery. After surgery and postoperative periods of 15, 30, 60, 90, and 120days, standardized radiographs were taken, digitized, and subjected to digital subtraction of the images using Adobe Photoshop CS software. Four years later, a cone-beam computed tomography was performed, showing bone repair and absence of root resorption at tooth #11. In this clinical case, digital subtraction radiography was effective for early detection of new bone formation and evolution of repair. © 2011 John Wiley & Sons A/S.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Os métodos de incubação de solo fornecem subsídios técnicos para a avaliação da mineralização e disponibilidade de N. Nesse sentido, os objetivos deste trabalho foram avaliar a mineralização potencial e líquida do N orgânico em solos e relacioná-la à disponibilidade de N para plantas. Amostras de 22 solos coletadas na camada arável (0 a 20 cm) foram submetidas à incubação em condições aeróbias a 35 °C, por 30 semanas, e anaeróbias a 40 °C, por sete dias, e utilizadas em experimento, em casa de vegetação, em que o milho foi a planta-teste. Durante a incubação por 30 semanas, houve aumento do N mineralizado na segunda semana, seguido de diminuição e estabilização a partir da quarta semana. Este comportamento resultou em ajuste do N mineralizado (Nm) ao modelo exponencial de decrescimento e do N mineralizado acumulado (Nmac) ao modelo exponencial de crescimento, a partir do qual foi possível calcular o N potencialmente mineralizável (N0). As quantidades de N0 refletiram a mineralização e a disponibilidade de N em longo prazo. Contudo, o Nmac apresentou maior grau de correlação com o N disponível medido pelas plantas (concentração de N e N acumulado na parte aérea) do que o N0, e valores altos de correlação foram obtidos já após duas semanas de incubação, o que indica que a modelagem matemática pode ser dispensada e o período de incubação pode ser encurtado. O N total do solo foi melhor índice da mineralização potencial e líquida de N orgânico do que a matéria orgânica do solo, principalmente em longo prazo. O método de incubação anaeróbia de curta duração pode ser utilizado para cálculo da estimativa do N0, e a subtração do N-NH4+ inicial não contribuiu para melhorar a estimativa da mineralização e da disponibilidade de N por meio deste método, o que o torna ainda mais simples e viável.
Resumo:
Teve-se o objetivo de verificar a possível seleção de sementes de milho - arredondadas e achatadas - no processo de semeadura com disco perfurado horizontal, bem como as conseqüências na distribuição longitudinal. Os registros dos dados deram-se pela avaliação visual de duas pessoas, com contador manual, no final da esteira carpetada em movimento de 1,54 m s-1, com 4,60 m de perspectiva para avaliação. Assim, um sensor registrava o número de orifícios do disco horizontal que devia passar pelo tubo condutor, e os espaçamentos falhos e múltiplos eram computados por pessoas diferentes. Os espaçamentos aceitáveis foram obtidos pela subtração dos espaçamentos falhos e múltiplos do total contabilizado. A medição do comprimento e espessura das sementes foi realizada com auxílio de paquímetro. Não houve alterações significativas nas variáveis estudadas, até a passagem de 55 mil orifícios do disco horizontal pelo tubo condutor; portanto, não houve seleção de sementes de milho durante a simulação do processo de semeadura.