17 resultados para signal noise

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

In a general way, in an electric power utility the current transformers (CT) are used to measurement and protection of transmission lines (TL) 1 The Power Line Carriers systems (PLC) are used for communication between electrical substations and transmission line protection. However, with the increasing use of optical fiber to communication (due mainly to its high data transmission rate and low signal-noise relation) this application loses potentiality. Therefore, other functions must be defined to equipments that are still in using, one of them is detecting faults (short-circuits) and transmission lines insulator strings damages 2. The purpose of this paper is to verify the possibility of using the path to the ground offered by the CTs instead of capacitive couplings / capacitive potential transformers to detect damaged insulators, since the current transformers are always present in all transmission lines (TL's) bays. To this a comparison between this new proposal and the PLC previous proposed system 2 is shown, evaluating the economical and technical points of view. ©2010 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Frequentemente, os indivíduos com perda auditiva têm dificuldade de entender a fala no ambiente ruidoso. OBJETIVO: O objetivo deste estudo foi avaliar clinicamente o desempenho dos indivíduos adultos com deficiência auditiva neurossensorial, com relação à percepção da fala, utilizando o aparelho de amplificação sonora individual digital com o algoritmo de redução de ruído denominado Speech Sensitive Processing, ativado e desativado na presença de um ruído. MATERIAL E MÉTODO: Este estudo de casos foi realizado em 32 indivíduos com deficiência auditiva neurossensorial de graus leve, moderado ou leve a moderado. Foi realizada a avaliação por meio de um teste de percepção de fala, onde se pesquisou o reconhecimento de sentenças na presença de um ruído, para obter a relação sinal/ruído, utilizando o aparelho auditivo digital. RESULTADOS: O algoritmo pôde proporcionar benefício para a maioria dos indivíduos deficientes auditivos, na pesquisa da relação sinal/ruído e os resultados apontaram diferença estatisticamente significante na condição em que o algoritmo encontrava-se ativado, comparado quando o algoritmo não se encontrava ativado. CONCLUSÃO: O uso do algoritmo de redução de ruído deve ser pensado como alternativa clínica, pois observamos a eficácia desse sistema na redução do ruído, melhorando a percepção da fala.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to determine the influence of hearing protection devices (HPDs) on the understanding of speech in young adults with normal hearing, both in a silent situation and in the presence of ambient noise. The experimental research was carried out with the following variables: five different conditions of HPD use (without protectors, with two earplugs and with two earmuffs); a type of noise (pink noise); 4 test levels (60, 70, 80 and 90 dB[A]); 6 signal/noise ratios (without noise, + 5, + 10, zero, - 5 and - 10 dB); 5 repetitions for each case, totalling 600 tests with 10 monosyllables in each one. The variable measure was the percentage of correctly heard words (monosyllabic) in the test. The results revealed that, at the lowest levels (60 and 70 dB), the protectors reduced the intelligibility of speech (compared to the tests without protectors) while, in the presence of ambient noise levels of 80 and 90 dB and unfavourable signal/noise ratios (0, -5 and -10 dB), the HPDs improved the intelligibility. A comparison of the effectiveness of earplugs versus earmuffs showed that the former offer greater efficiency in respect to the recognition of speech, providing a 30% improvement over situations in which no protection is used. As might be expected, this study confirmed that the protectors' influence on speech intelligibility is related directly to the spectral curve of the protector's attenuation. (C) 2003 Elsevier B.V. Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Turnera diffusa Willd. var. afrodisiaca (Ward) Urb. (syn. T. aphrodisiaca) belongs to the family of Turneraceae and is an aromatic plant growing wild in the subtropical regions of America and Africa. It is widely used in the traditional medicine as e.g. anti-cough, diuretic, and aphrodisiac agent. This work presents a 3 min chromatographic analysis using low-pressure (LP) gas chromatography (GC)-ion-trap (IT) mass spectrometry (MS). The combination of a deactivated 0.6 m x 0.10 mm i.d., restrictor with a wide-bore CP-Wax 52 capillary column (10 m x 0.53 mm i.d., 1 mum) reduces the analysis time by a factor of 3-7 in comparison to the use of a conventional narrow bore column. Chromatographic conditions have been optimized to achieve the fastest separation with the highest signal/noise ratio in MS detection. These results allow fast and reliable quality control of the essential oil to be achieved. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Biologia Geral e Aplicada - IBB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel AC Biosusceptometry (ACB) system with thirteen sensors it was implemented and characterized in vitro using magnetic phantoms. The system presenting coils in a coaxial arrangement with one pair of excitation coil outside and thirteen pairs of detection coils inside. A first-order gradiometric configuration was utilized for optimal detection of magnetic signals. Several physical parameters such as baseline, number of turns, excitation field and diameters were studied for improvement of the signal/noise ratio. This system exhibits an enhanced sensitivity and spatial resolution, due to the higher density of sensors/area. In the future those characteristics will turn possible to obtain images of magnetic marker or tracer in the gastrointestinal tract focusing on physiological and pharmaceutical studies. ACB emerged due to its interesting nature, noninvasiveness and low cost to investigate gastrointestinal parameters and this system can contribute for more accurate interpretation of biomedical signals and images

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper describes a speech enhancement system (SES) based on a TMS320C31 digital signal processor (DSP) for real-time application. The SES algorithm is based on a modified spectral subtraction method and a new speech activity detector (SAD) is used. The system presents a medium computational load and a sampling rate up to 18 kHz can be used. The goal is load and a sampling rate up to 18 kHz can be used. The goal is to use it to reduce noise in an analog telephone line.