6 resultados para safer speeds

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Broiler production in Brazil has turned into a very competitive activity in the late years. Constant innovation leads to higher productivity maintaining the same cost of production, which is a desirable situation. Lately one characteristic for broiler housing in Brazil has been the increase in birds density requiring the use of controlled environment through the use of fan and fogging systems in order to achieve better birds productive performance. Most Brazilian producer already uses cooling equipment however it is still unknown the right way to control the wind speed and direction towards the birds. This present research has the objective to evaluate the effect of the wind speed on the heat transfer from the birds to the environment for broilers at 27 days old. There was used 200 birds, placed in a wind tunnel measuring 1.10 m high by 1.10m wide x 10.0 m of length, and the birds density varied from 9, 16 and 20 birds/m 2. Two wind speed were simulated 340 rpm (1.0 m/s) and 250 rpm (0.3 m/s). The increase in the wind velocity related to the smaller bird densityled to a higher heat loss and to a more uniform temperature distribution in its exposed areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to identify the boundary of submaximal speed zones (i.e., exercise intensity domains) between maximal aerobic speed (S-400) and lactate threshold (LT) in swimming. A 400-m all-out test, a 7 × 200 m incremental step test, and two to four 30-minute submaximal tests were performed by 12 male endurance swimmers (age = 24.5 ± 9.6 years; body mass = 71.3 ± 9.8 kg) to determine S-400, speed corresponding to LT, and maximal lactate steady state (MLSS). S-400 was 1.30 ± 0.09 m·s -1 (400 m-5:08 minutes:seconds). The speed at LT (1.08 ± 0.02 m·s-1; 83.1 ± 2.2 %S-400) was lower than the speed at MLSS (1.14 ± 0.02 m·s-1; 87.5 ± 1.9 %S-400). Maximal lactate steady state occurred at 26 ± 10% of the difference between the speed at LT and S-400. Mean blood lactate values at the speeds corresponding to LT and MLSS were 2.45 ± 1.13 mmol·L-1 and 4.30 ± 1.32 mmol·L-1, respectively. The present findings demonstrate that the range of intensity zones between LT and MLSS (i.e., heavy domain) and between MLSS and S-400 (i.e., severe domain) are very narrow in swimming with LT occurring at 83% S-400 in trained swimmers. Precision and sensitivity of the measurement of aerobic indexes (i.e., LT and MLSS) should be considered when conducting exercise training and testing in swimming. © 2013 National Strength and Conditioning Association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the importance of an innovative analytical technique for drugs and pharmaceuticals quantification, using Fouriertransform infrared (FTIR) transmission spectroscopy. This method does not use organic solvents, which is one great advantage over the most common analytical methods. This fact contributes to minimize the generation of organic solvent waste by the industry and thereby reduces the impact of its activities on the environment. The method involved absorbance measurements of the band corresponding to one of the chosen group in the molecule. Obviously, the method should be validated according to ICH guidelines, showing linearity, precision, accuracy and robustness, over a concentration range, using small amounts to prepare the analyte. The validated method is able to quantify drugs and pharmaceuticals and can be used as an environmentally friendly alternative for the routine analysis in pharmaceutical industry quality control.