Resumo:
OBJECTIVETo determine the current status of the literature regarding the clinical efficacy and complication rates of cryoablation vs radiofrequency ablation in the treatment of small renal tumours.METHODSA review of the literature was conducted. There was no language restriction. Studies were obtained from the following sources: MEDLINE, EMBASE and LILACS.Inclusion criteria were (i) case series design with more than one case reported, (ii) use of cryoablation or radiofrequency ablation, (iii) patients with renal cell carcinoma and, (iv) outcome reported as clinical efficacy.When available, we also quantified the complication rates from each included study.Proportional meta-analysis was performed on both outcomes with a random-effects model. The 95% confidential intervals were also calculated.RESULTSThirty-one case series (20 cryoablation, 11 radiofrequency ablation) met all inclusion criteria.The pooled proportion of clinical efficacy was 89% in cryoablation therapy from a total of 457 cases. There was a statistically significant heterogeneity between these studies showing the inconsistency of clinical and methodological aspects.The pooled proportion of clinical efficacy was 90% in radiofrequency ablation therapy from a total of 426 cases. There was no statistically significant heterogeneity between these studies.There was no statistically significant difference regarding complications rate between cryoablation and radiofrequency ablation.CONCLUSIONSThis review shows that both ablation therapies have similar efficacy and complication rates.There is urgency for performing clinical trials with long-term data to establish which intervention is most suitable for the treatment of small renal masses.
Resumo:
Purpose: Small renal masses are increasingly being discovered incidentally on imaging for another reason. The standard of care of these masses involves excision by open or laparoscopic techniques. Recently, ablative techniques, such as radiofrequency ablation (RFA) and cryoablation, have taken a more prominent role in the treatment algorithm of these masses. We evaluate the effectiveness and safety of cryoablation to treat renal tumours. Methods: A review of the literature was conducted. There was no language restriction. Studies were obtained from the following sources: the Cochrane Library, PUBMED, EMBASE and LILACS. Results: There was no clinical trial identified in the literature. Thus, we described the results from 23 case series and retrospective studies with a reasonable sample size (number of reported patients in each study ≥30), with a total of 2104 analyzed tumours from 2038 patients. There was wide variability in the outcomes reported, but success rates were generally good. Follow-up was generally short, but some series reported outcomes at 5 years. The most common complications reported were hemorrhage (some of the patients requiring transfusion), perinephric hematoma and urine leaks. Conclusion: Cryoablation presents a feasible treatment for patients with small renal masses. Only short-term data are available and, as such, meaningful conclusions regarding long-term cancer control cannot be made. More rigorous studies are needed. © 2013 Canadian Urological Association.
Resumo:
PURPOSE: Systematic reviews are criticized for frequently offering inconsistent evidences and absence of straightforward recommendations. Their value seems to be depreciated when the conclusions are uncertain. To describe an alternative approach of evaluating case series studies in health care when there is absence of clinical trials. METHODS: We provide illustrations from recent experiences. Proportional meta-analysis was performed on surgical outcomes: (a) case series studies, (b) use of cryoablation or radiofrequency ablation, and (c) patients with small renal cell carcinoma. The statistically significant difference between both interventions studied was defined if their combined 95% confidential interval (CI) did not overlap. RESULTS: As demonstrated by the example, this analysis is an alternative approach to provide some evidence of the intervention´s effects under evaluation and plotting all available case series in the absence of clinical trials for the health field. CONCLUSIONS: Although we are leading to a low level of evidence to determine efficacy, effectiveness and safety of interventions this alternative approach can help surgeons, physicians and health professionals for a provisionally decision in health care along with their clinical expertise and the patient´s wishes and circumstances in the absence of high-quality primary studies. It´s not a replacement for the gold standard randomized clinical trial, but an alternative analysis for clinical research.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Titanium surface texture and chemistry modification successfully improves the host response and consequently the bone-to-implant contact surrounding dental implants. The aim of the present study was to investigate, using histomorphometrical-analysis, the effects of titanium surface modification by laser-ablation (Nd:YAG) followed by thin chemical deposition of HA. Forty-eight rabbits received one implant by tibiae of AS-machined (MS), laser-modified (LMS), or biomimetic hydroxyapatite-coated (HA) surface. Bone-to-implant contact (BIC) and bone area (BBT) were evaluated after 4, 8, and 12 weeks, at cortical and cancellous regions. Average BIC in the cortical region was higher (P < 0.001) on the LMS and HA implants for all periods, with no differences between LMS and HA. For the cancellous area, the LMS and HA implants showed higher (P < 0.01) BIC than MS at the initial periods. The LMS and HA showed similar values in the cortical region, but a tendency of higher values for HA in the cancellous region was observed in all periods. For the BBT, the differences were found only between HA and MS after 4 weeks in the cortical region (P < 0.05), and after 12 weeks in the cancellous area (P < 0.05). Our results showed that HA biomimetic coating preceded by laser treatment induced the contact osteogenesis and allowed the formation of a more stable boneimplant interface, even in earlier periods. Microsc. Res. Tech., 2012. (C) 2012 Wiley Periodicals, Inc.
Resumo:
The nucleus of the solitary tract (NTS) receives primary afferents involved in cardiovascular regulation. We investigated the role of NK1-receptor bearing neurons in the NTS on cardiovascular reflexes in awake rats fitted with chronic venous and arterial cannulae. These neurons were lesioned selectively with saporin conjugated with substance P (SP-SAP, 2 mu M, bilateral injections of 20 nL in the subpostremal NTS, or 200 nL in both the subpostremal and the commissural NTS). Before, and 7 and 14 days after injection of SP-SAP, we measured changes in blood pressure and heart rate induced by i.v. injection of phenylephrine and nitroprusside (baroreceptor reflex), cyanide (arterial chemoreceptor reflex), and phenylbiguanide (Bezold-Jarisch reflex). The smaller injections with SP-SAP completely abolished NK1 receptor staining in the subpostremal NTS. The larger injections abolished NK1 receptor immunoreactivity in an area that extended from the commissural NTS to the rostral end of the subpostremal NTS. The lesions seemed to affect only a limited number of neurons, since neutral red stained sections did not show any obvious reduction in cell number. The smaller lesions reduced the gain of baroreflex bradycardia and the hypotension induced by phenylbiguanide. The larger lesions completely abolished the response to phenylbiguanide, blocked the baroreflex bradycardia induced by phenylephrine, severely blunted the baroreflex tachycardia, and blocked the bradycardia and reduced the hypertension induced by cyanide. Thus, these responses depend critically on NK1-receptor bearing neurons in the NTS. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
By means of IR spectroscopy, we determined the teeth ablation mechanism by an Er:YAG laser oscillating at 2.94 mum. Ejected dental material, ablated by the laser from human teeth, was deposited on an IR window and the absorption spectra were measured in the range 2500-20,000 nm. Sound teeth were used, and the corresponding film spectra were compared to spectra obtained by traditional methods. The films spectra obtained do not differ appreciably from those obtained by the traditional method for sound teeth, indicating that the material ejected by an Er:YAG represents the tooth condition.The obtained results confirm that a spectroscopic analysis of a tooth treated with an Er:YAG laser can be done measuring the absorbance of a film composed of ejected material without the need to slice it. In addition, we could determine that the laser absorption occurs mainly by the interstitial water, and the temperature elevation of the ejected material does not exceed 60degreesC. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
This study was conducted to analyze the ablation rate and micromorphological aspects of microcavities in enamel and dentin of primary and permanent teeth using a Er:YAG laser system. Micromorphological evaluation has been performed in terms of permanent teeth; however, little information about Er: YAG laser interaction with primary teeth can be found in the literature. Because children have been the most beneficiary patients with laser therapy in our offices, it is extremely necessary to compare the effects of this kind of laser system on the enamel and dentin of permanent and primary teeth. In this study, we used eleven intact primary anterior exfoliated teeth and six extracted permanent molar teeth. We used a commercial laser system: a Er: YAG Twin Light laser system (Fotona Medical Lasers, Slovenia) at 2940 nm, changing average energy levels per pulse ( 100, 200, 300, and 400 mJ) producing 48 microcavities in enamel and dentin of primary and permanent teeth. Primary teeth are more easily ablated than are permanent teeth, when related to enamel or dentin. However, while this laser system is capable of slowly revealing the enamel's microstructure, in dentin only the lowest laser energies permit this kind of observation, more easily decomposing the original tissue aspect, when related to primary or permanent teeth. Statistically, the only different factor at the 5% level was an energy per pulse of 400 mJ, confirming the results found in SEM. Our results showed that dentin in both primary and permanent teeth is less resistant to Er: YAG laser ablation; this fact is easily observed under SEM observation and through the ablation rate evaluation.
Resumo:
A regimen of progesterone plus estradiol (P&E) was used as a standard for ovarian synchronization to test the efficacy and evaluate the commercial application of ultrasound-guided follicle ablation as a non-steroidal alternative for ovulation synchronization in mares. Recipient mares at a private embryo transfer facility were at unknown stages of the estrous cycle at the start of the experiment on Day 1 when they were randomly assigned to an ablation group (n = 18-21 mares) or to a ME group (n = 20-21 mares). In the ablation group, mares were lightly sedated and all follicles > 10 mm were removed by transvaginal ultrasound-guided follicle aspiration. In the ME group, a combination of progesterone (150 mg) plus estradiol (10 mg) prepared in safflower oil was given daily (im) for 10 d. Two doses of prostaglandin FZ, (PGF, 10 mg/dose, im) were given 12 h apart on Day 5 in the ablation group, or a single dose on Day 10 in the ME group. Human chorionic gonadotropin (hCG, 2500 IU/mare, im) was given at a fixed time, 6 and 10 d after PGF treatment in the ablation and ME groups, respectively, with the expectation of a follicle > 30 mm at the time of treatment. In both the ablation and P&E groups, transrectal ultrasonography was done at the start of the study (Day 1) and again on the day of hCG treatment and daily thereafter to determine the presence of a CL, measure diameter of the largest follicle and detect ovulation. The mean interval from the start of the study and from PGF treatment to ovulation was shorter (P < 0.0001) in the ablation group (13.7 and 9.7 d, respectively) compared to the P&E group (22.3 and 13.2 d, respectively). Following fixed-day treatment with hCG after PGF treatment, the degree of ovulation synchronization was not different (P > 0.05) between the ablation and P&E groups within a 2-d (56 and 70%) or 4-d (83% and 90%) period. Although ultrasound-guided follicle ablation may not be practical in all circumstances, it excluded the conventional 10-d regimen of progesterone and estradiol and was considered an efficacious and feasible, non-steroidal alternative for ovulation synchronization in mares during the estrous cycle. (C 2007 Elsevier B.V. All rights reserved.