172 resultados para prostheses and orthoses
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The effects of Tissucol and Tissucol/EACA on bone healing were evaluated histologically. Experimental defects were made in both tibias of 25 rats. Test materials were placed in defects in right tibias and left tibias served as control. Five animals in each group were killed at 1, 3, 7, 14 and 21 days after surgery. Results showed that: a) Tissucol did not interfere with connective and osseous tissue formation; b) Tissucol allowed new bone formation; c) Tissue residues in Tissucol groups in sections of 21-day specimens did not impair healing; d) Tissucol/EACA was usually completely resorbed and healing was complete 21 days after surgery in the Tissucol/EACA group.
Resumo:
The purpose of this implant study was to evaluate the transverse stability of the basal maxillary and mandibular structures. The sample included 25 subjects between 12 and 18 years of age who were followed for approximately 2.6 years. Metallic implants were placed bilaterally into the maxillary and mandibular corpora before treatment. Once implant stability had been confirmed, treatment (4 first premolar extractions followed by fixed appliance therapy) was initiated. Changes in the transverse maxillary and mandibular implants were evaluated cephalometrically and two groups (GROW+ and GROW++; selection based on growth changes in facial height and mandibular length) were compared. The GROW++ group showed significant width increases of the posterior maxillary implants (P <.001) and the mandibular implants (P =.009); there was no significant change for the anterior maxillary implants. The GROW+ group showed no significant width changes between the maxillary and mandibular implants. We conclude that (1) there are significant width increases during late adolescence of the basal mandibular and maxillary skeletal structures and (2) the width changes are related with growth potential.
Resumo:
This research evaluated the bone repair process after implantation of homogenous demineralized dentin matrix (HDDM) in surgical defects in the parietal bone of rabbits with alloxan-induced diabetes, using a polytetrafluorethylene (PTFe) barrier for guided bone regeneration. Thirty-six rabbits were used and divided into four groups: control (C, n = 12), diabetic (D, n = 12, left parietal bone), diabetic with PTFe (DPTFe, same 12 rabbits, right parietal bone), and diabetic with PTFe associated to HDDM (D-PTFe+HDDM, n = 12). Bone defects were created in the parietal bone of the rabbits and the experimental treatments were performed, where applicable. The rabbits were sacrificed after 15, 30, 60 and 90 days. The bone defects were examined radiographically and by optical density (ANOVA and Tukey test, p < .05). The radiographic findings showed that the D-PTFe+HDDM group presented greater radiopacity and better trabecular bone arrangement when compared to that of the C, D and D-PTFe groups. The statistical analysis showed significant differences in the optical density of the newly formed bone among the studied groups. It was possible to conclude that HDDM was biocompatible in diabetic rabbits.
Resumo:
During the process of facial rehabilitation, the mobility of ocular prostheses must be considered. Whereas some factors depend exclusively on the dentist, such as molding techniques and selection of material for denture construction, regarding ocular rehabilitation, factors, such as type of surgery, whether to adopt implants, and the use of lubricants, deserve special attention owing to their integration and their association with other factors pertaining exclusively to the patient. To establish harmony, and with the intention of aiding the dentist, after a discerning evaluation, the authors of this study report the factors that provide greater or less mobility to ocular prostheses and conceal the prosthesis in a more natural way, thereby contributing toward achieving a favorable aesthetic result in rehabilitations.
Resumo:
The purpose of this Study was to evaluate Soft tissue response to rnaxillo-mandibular counter-clockwise rotation, with TMJ reconstruction and mandibular advancement using TMJ Concepts (R) total joint prostheses, and maxillary osteotomies in 44 females. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one Surgeon (Wolford). Eighteen patients had genioplasties with either porous block hydroxyapatite or hard tissue replacement implants (Group 2) 26 had no genioplasty (Group 1). Surgically, the maxilla moved forward and upward by counter-clockwise maxillo-mandibular rotation with greater horizontal movement in Group 2. Vertically, both groups showed diversity of maxillo-mandibular mean movement. Group I showed a consistent 1:0.97 ratio of hard to soft tissue advancement at pogonion; Group 2 results were less consistent, with ratios between 1:0.84 and 1:1.02. Horizontal changes in upper lip morphology after maxillary advancement/impaction, VY closure, and alar base cinch sutures showed greater movement in both groups, than observed in hard tissue. Counter-clockwise rotation of the maxillo-mandibular complex using TMJ Concepts total joint prostheses resulted in similar soft tissue response as previously reported for traditional maxillo-mandibular advancement without counter-clockwise rotation of the occlusal plane. The association of chin implants, in the present sample, showed higher variability of soft tissue response.
Resumo:
47 end-stage TMJ patients with high occlusal plane angulation, treated with TMJ custom-fitted total joint prostheses and simultaneous maxillo-mandibular counter-clockwise rotation were evaluated for pain and dysfunction presurgery (T1) and at the longest follow-up (T2). Patients subjectively rated their facial pain/headache, TMJ pain, jaw function, diet and disability. Objective functional changes were determined by measuring maximum interincisal opening (MIO) and laterotrusive movements. Patients were divided according to the number of previous failed TMJ surgeries: Group 1 (0-1), Group 2 (2 or more). Significant subjective pain and dysfunction improvements (37-52%) were observed (<0.001). MIO increased 14% but lateral excursion decreased 60%. The groups presented similar absolute changes, but Group 2 showed more dysfunction at T1 and T2. For patients who did not receive fat grafts around the prostheses and had previous failure of proplast/teflon and or silastic TMJ implants, more than half required surgery for TMJ debridement and removal of foreign body giant cell reaction and heterotopic bone formation. End-stage TMJ patients can be treated in one operation with TMJ custom-made total joint prostheses and maxillo-mandibular counter-clockwise rotation, for correction of dentofacial deformity and improvement in pain and TMJ dysfunction; Group 1 patients had better results than Group 2 patients.
Resumo:
The purpose of this study was to evaluate the anatomical changes and stability of the oropharyngeal airway and head Posture following TMJ reconstruction and mandibular advancement with TMJ Concepts custom-made total joint prostheses and maxillary osteotomies with counter-clockwise rotation of the maxillo-mandibular complex. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one surgeon (Wolford). The lateral cephalograms of 47 patients were analyzed to determine surgical and post-surgical changes of the oropharyngeal airway, hyoid bone and head posture. Surgery increased the narrowest retroglossal airway space 4.9 mm. Head Posture showed flexure immediately after surgery (-5.6 +/- 6.7 degrees) and extension long-term post surgery (1.8 +/- 6.7 degrees); cervical curvature showed no significant change. Surgery increased the distances between the third cervical vertebrae and the menton 11.7 +/- 9.1 mm and the third cervical vertebrae and hyoid 3.2 +/- 3.9 mm, and remained stable. The distance from the hyoid to the mandibular plane decreased during surgery (-3.8 +/- 5.8 mm) and after surgery (-2.5 +/- 5.2 mm), Maxillo-mandibular advancement with counter-clockwise rotation and TMJ reconstruction with total joint prostheses produced immediate increase in oropharyngeal airway dimension, which was influenced by long-term changes in head posture but remained stable over the follow-up period.
Resumo:
Objective: The aim of this study was to analyse denture users' oral care habits with regard to the use of their prostheses. Background: Rehabilitative treatment is only successful when patients are motivated and aware of correct prosthesis use and hygiene. Materials and methods: Questionnaires were distributed to 150 complete denture users at the Federal University of Bahia School of Dentistry, the Esmeralda Natividade Health Center, the Bahian Science Development Foundation and a Salvador nursing home. The questionnaire included information on gender, age, length of prosthesis use, cleaning methods and materials, etc. The data were analysed using EpiInfo version 6 software. The chi-squared test was used for statistical analysis, with a significance level of 5%. Results: Questionnaire results showed that 78% of the subjects, with an average age of 67.3 years, had used the same complete denture for over 5 years. 64% slept with their prostheses and 44% removed them from the mouth only for cleaning. None of the patients interviewed knew anything about brushes designed specifically for complete dentures. 37.3% had a restricted diet and 44% believed that a complete denture would last for more than 10 years. Conclusion: Within the limitations of this study, it was concluded that the edentulous patients surveyed had limited awareness of prosthetic hygiene and long-term oral care despite extended periods of denture use. © 2008 The Authors.
Resumo:
Objectives: The objective of this study was to evaluate by a visual method of comparison the color stability of nonpigmented and pigmented facial silicones after accelerated aging. Materials and Methods: Two kinds of silicones were used in this study; one specifically formulated for facial prostheses and the other an acetic silicone for industrial use. Twenty-four trial bodies were made for each silicone. These were divided into colorless and intrinsically pigmented groups: ceramic, make-up, and iron oxide. The groups were submitted to accelerated aging for nonmetallic materials. An initial reading and subsequent readings were made at 163, 351, 692, and 1000 hours using a visual method of comparison. The values were annotated in a spreadsheet by two observers, according to scores elaborated for this study. Results: All groups presented color stability in the visual method. According to the results obtained and analyzed in this study, we can conclude that both silicones, Silastic 732 RTV and Silastic MDX 4-4210, behaved similarly, they can therefore be indicated for use in maxillofacial prosthesis. The time factor of aging influenced negatively, independently of the pigmentation, or lack of it, and of silicones and no group had visually noticeable alterations in any of the accelerated aging time, independently of the addition or not of pigments.
Resumo:
The aim of this study was to present the factors that influence planning for immediate loading of implants through a literature review for treatment success. Research was conducted in the PubMed database including the key words immediate implant loading, implant-supported prostheses, and implant planning for studies published from 2000 to 2011. Forty-eight articles were used in this review to describe the indications and counterindications, presurgical planning, and technologies available for planning of this treatment alternative.
Resumo:
Implants in craniofacial reconstructions improve prostheses retention and stability, comfort, and safety for the patient. According to biomechanical principles, the treatment success regarding osseointegration maintenance depends on an adequate surgery technique associated to a retention system that provides favorable tension distribution to implants. Implants in the mastoid area are a very important aid for retention of auricular prostheses. Color stability of resin and silicone is an important factor for longevity of auricular prostheses, and the high degree of satisfaction of patients with head and neck defects receiving epithesial reconstruction in the maxillofacial region is demonstrated.
Resumo:
Techniques of rapid prototyping were introduced in the 1980s in the field of engineering for the fabrication of a solid model based on a computed file. After its introduction in the biomedical field, several applications were raised for the fabrication of models to ease surgical planning and simulation in implantology, neurosurgery, and orthopedics, as well as for the fabrication of maxillofacial prostheses. Hence, the literature has described the evolution of rapid prototyping technique in health care, which allowed easier technique, improved surgical results, and fabrication of maxillofacial prostheses. Accordingly, a literature review on MEDLINE ( PubMed) database was conducted using the keywords rapid prototyping, surgical planning, and maxillofacial prostheses and based on articles published from 1981 to 2010. After reading the titles and abstracts of the articles, 50 studies were selected owing to their correlations with the aim of the current study. Several studies show that the prototypes have been used in different dental-medical areas such as maxillofacial and craniofacial surgery; implantology; neurosurgery; orthopedics; scaffolds of ceramic, polymeric, and metallic materials; and fabrication of personalized maxillofacial prostheses. Therefore, prototyping has been an indispensable tool in several studies and helpful for surgical planning and fabrication of prostheses and implants.
Resumo:
The use of implants to rehabilitation of total edentulous, partial edentulous or single tooth is increasing, it is due to the high rate of success that this type of treatment present. The objective of this study was to analyze the mechanical behavior of different positions of two dental implants in a rehabilitation of 4 teeth in the region of maxilla anterior. The groups studied were divided according the positioning of the implants. The Group 1: Internal Hexagonal implant in position of lateral incisors and pontic in region of central incisors; Group 2: Internal Hexagonal implant in position of central incisors and cantilever of the lateral incisors and Group3 - : Internal Hexagonal implants alternate with suspended elements. The Electronic Speckle Pattern Interferometry (ESPI) technique was selected for the mechanical evaluation of the 3 groups performance. The results are shown in interferometric phase maps representing the displacement field of the prosthetic structure.
Resumo:
Fanconi anemia (FA) is a rare autosomal recessive disorder, characterized by pancytopenia and progressive hypoplasia of the bone marrow. A 23-year-old woman with FA showed severe pancytopenia and developed an abscess on the infraorbicular region on the right side of the face that progressed to phlegmon and caused tissue necrosis of the nostrils, nasal septum, nasal fossa, and posterior orbital region. Laboratory examination showed Streptococcus parasanguis as the etiologic agent of the phlegmon. Supportive treatment was recommended due to donor incompatibility for bone marrow transplant. The intraoral examination showed spontaneous gingival bleeding, edema of the interdental papillae, hematomas on the superior and inferior lips, bacterial and fungal infections, and adequate oral hygiene. The patient was treated with the administration of an antibiotic (imipenem), an antifungal (amphotericin B), and mouth washing with antiseptic solutions. Periodontal prophylaxis and orientation to and control of oral hygiene and diet were also used during the remission period. For functional and esthetic rehabilitation of the alar regions and nasal dorsum, an acrylic resin nasal prosthesis was made, supported by a spectacle frame.
Resumo:
Purpose: To evaluate the histological and systemic response to subcutaneous injection of polyethylene gel in rats. Methods: Twenty-one white male rats were divided into 3 groups (G): G1 and G2 received subcutaneous polyethylene gel injection in the dorsal midline and were sacrificed at 30 and 60 postoperative days, respectively. G3 was not exposed to the polyethylene gel and was sacrificed after 60 days. Blood levels of lactate dehydrogenase (LDH), creatine kinase (CK), and alkaline phosphatase (ALP) were evaluated. The heart, kidney, liver, adrenal gland, injection site, and adjacent tissues were histologically examined. The results were submitted to statistical analysis. Results: There was no clinical evidence of extrusion, reduction of the injected volume, or abnormalities in the adjacent tissues. Blood levels of CK and LDH were normal and similar in all groups. ALP levels were significantly lower in G2 than in G1 and G3. The systemic organs were normal on histological examination in the 3 groups evaluated. Microscopically, the polyethylene gel was surrounded by a thin pseudocapsule formation and minimal inflammatory cell response, which decreased from G1 to G2. Conclusion: The subcutaneous injection of polyethylene gel in rats elicited minimal local inflammatory response and no systemic side effects. Copyright © 2008 Informa Healthcare USA, Inc.