12 resultados para pooled blood sera

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid, robust and economical method for the analysis of persistent halogenated organic compounds in small volumes of human serum and umbilical cord blood is described. The pollutants studied cover a broad range of molecules of contemporary epidemiological and legislative concern, including polychlorobiphenyls (PCBs), polychlorobenzenes (CBs), hexachlorocyclohexanes (HCHs), DDTs, polychlorostyrenes (PCSs) and polybromodiphenyl ethers (PBDEs). Extraction and clean-up with n-hexane and concentrated sulphuric acid was followed with analysis by gas chromatography coupled to electron capture (GC-ECD) and GC coupled to negative ion chemical ionisation mass spectrometry (GC-NICI-MS). The advantages of this method rest in the broad range of analytes and its simplicity and robustness, while the use of concentrated sulphuric acid extraction/clean-up destroys viruses that may be present in the samples. Small volumes of reference serum between 50 and 1000 μL were extracted and the limits of detection/quantification and repeatability were determined. Recoveries of spiked compounds for the extraction of small volumes (≥300 μL) of the spiked reference serum were between 90% and 120%. The coefficients of variation of repeatability ranged from 0.1-14%, depending on the compound. Samples of 4-year-old serum and umbilical cord blood (n = 73 and 40, respectively) from a population inhabiting a village near a chloro-alkali plant were screened for the above-mentioned halogenated pollutants using this method and the results are briefly described. © 2010 Springer-Verlag.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O Sistema ABO foi descoberto em 1900 e permanece até hoje como sendo o sistema mais importante dentro da prática transfusional. A transfusão ABO incorreta pode resultar na morte do paciente, com uma reação hemolítica intravascular, seguida de alterações imunológicas e bioquímicas. Os anticorpos ABO estão presentes nos soros dos indivíduos, dirigidos contra os antígenos A e/ou B ausentes nas hemácias. Embora as transfusões com pequenas quantias de plasmas incompatíveis sejam geralmente consideradas uma prática segura, alguns casos de reações hemolíticas por plasma incompatível são encontrados na literatura. Tendo em vista a pequena quantidade de estudos sobre as hemolisinas anti-A e anti-B e a importância desses anticorpos na prática transfusional, objetivamos neste trabalho verificar a freqüência dessas hemolisinas em doadores de sangue do Hemocentro da Unesp de Botucatu. Foram analisadas 600 amostras de soros de doadores do grupo O para presença ou ausência das hemolisinas anti-A e anti-B. Desses doadores, 77 (12,8%) foram classificados como perigosos por apresentarem em seu soro altos títulos de hemolisinas e 523 (87,2%) como não perigosos por apresentarem baixos títulos. No grupo dos doadores perigosos, 45 (58,4%) foram reativos para hemolisina anti-A, 11 (14,2%) reativos para hemolisina anti-B e 21 (27,2%) reativos para ambas. O título de aglutininas superior a 1/100 já considera o doador O como perigoso. Assim, o teste realizado em nossa rotina é suficiente para detecção de altos títulos fazendo com que os pacientes dos outros grupos sangüíneos não corram o risco de reação transfusional se necessitarem de transfusão sangüínea não-isogrupo.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Detection of Toxoplasma gondii (T. gondii) DNA in blood can help to diagnose the disease in its acute phase; however, it must be considered that hemoglobin, present in blood, can inhibit polymerase activity, making impracticable the detection of DNA in samples. Mice were experimentally infected via oral route with ME49 and BTU2 strains cysts and RH strain tachyzoites; polymerase chain reaction was used to detect T. gondii DNA in mice sera 18, 24, 48, 96, and 192 hours post infection (PI). Toxoplama gondii DNA was detected in only one animal infected with BTU2 strain, genotype III (isolated from a dog with neurological signs) 18 hours PI. The agent's DNA was not detected in any sample of the other experimental groups. New studies must be carried out to verify the technique sensitivity in researches on this agent's genetic material using sera samples of acute-phase toxoplasmosis patients, especially in cases of immunosuppression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To investigate functional changes in Trypanosoma cruzi parasites induced during their interaction with the vertebrate host, we compared the blood clearance profiles of blood forms isolated from infected normal mice (Reg-Tc) or from infected mice immunodepressed after treatment with cyclophosphamide (Cy-Tc). Parasite blood numbers were measured at various time intervals in animals injected intravenously (i.v.) with 1-2 x 10(6) T. cruzi of either isolate. In the absence of added immune sera (spontaneous clearance), Reg-Tc and Cy-Tc were cleared from blood at similar rates. However, when acute immune mouse serum (Ac-IMS) was injected i.v. 2 min after inoculation of parasites, a significant proportion of Cy-Tc only was cleared from the blood an hour later, whereas Reg-Tc were not, their clearance profile being identical to that observed in mice injected with normal mouse serum. Cy-Tc susceptibility to Ac-IMS was not the result of a toxic effect of cyclophosphamide over T. cruzi as parasites recovered from animals immunodepressed by irradiation before infection were cleared similarly by acute serum. Contrary to Ac-IMS, chronic immune mouse serum induced similar rates of disappearance of Reg-Tc and Cy-Tc from blood. Our results suggest the occurrence of T. cruzi selection or modification during the acute phase, which leads to an increased parasite resistance to the clearance properties of acute-phase antibodies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present investigation was to determine the course of maternal blood glucose levels in pregnant rats and its repercussions on the glucose levels and pancreas of their newborn pups. Diabetes was induced by alloxan (42 mg/kg body weight) and streptozotocin (40 mg/kg). Sixty-two pregnant Wistar rats weighing 180 to 250 g were divided into a control group and two groups with moderate (120 to 200 mg/dl glucose) and severe diabetes (greater than 200 mg/dl glucose), respectively. Blood glucose levels were measured in the dams on the 1st, 14th, and 21st days of pregnancy and in the pups at birth. The results were pooled for each litter. The fetal pancreases were removed after cesarian section performed on the 21st day of pregnancy, pooled for each litter and processed for histopathologic examination by light microscopy. Maternal blood glucose levels were significantly increased compared with the first day of pregnancy in both normal and diabetic rats starting on the 14th day of pregnancy. Fetal blood glucose levels correlated with maternal levels. The histopathologic changes characterized by vacuolization and basophilia of the cytoplasm of endocrine pancreas of newborn pups from darns with moderate or severe diabetes suggested pancreatic hyperactivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Indirect ELISA and IFAT have been reported to be more sensitive and specific than agglutination tests. However, MAT is cheaper, easier than the others and does not need special equipment. The purpose of this study was to compare an enzyme linked immunosorbent assay using crude rhoptries of Toxoplasma gondii as coating wells (r-ELISA) with indirect fluorescence antibody test (IFAT) and modified agglutination test (MAT) to detect anti-T. gondii antibodies in sera of experimentally infected pigs. Ten mixed breed pigs between 6.5 and 7.5 weeks old were used. All pigs were negative for the presence of T. gondii antibodies by IFAT (titre < 16), r-ELISA (OD < 0.295) and MAT (titre < 16). Animals received 7 × 107 viable tachyzoites of the RH strain by intramuscular (IM) route at day 0. Serum samples were collected at days -6, 0, 7, 14, 21, 28, 35, 42, 50, and 57. IFAT detected anti-T. gondii antibodies earlier than r-ELISA and MAT. The average of antibody levels was higher at day 35 in IFAT (Log10 = 2.9) and in MAT (Log10 = 3.5), and at day 42 in r-ELISA (OD = 0.797). The antibody levels remained high through the 57th day after inoculation in MAT, and there was a decrease tendency in r-ELISA and IFAT. IFAT was used as gold standard and r-ELISA demonstrated a higher prevalence (73.3%), sensitivity (94.3%), negative predictive value (83.3%), and accuracy (95.6%) than MAT. Kappa agreements among tests were calculated, and the best results were shown by r-ELISA × IFAT (κ = 0.88, p < 0.001). Cross-reaction with Sarcocystis miescheriana was investigated in r-ELISA and OD mean was 0.163 ± 0.035 (n = 65). Additionally, none of the animals inoculated with Sarcocystis reacted positively in r-ELISA. Our results indicate that r-ELISA could be a good method for serological detection of T. gondii infection in pigs. © 2005 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High throughput sequencing (HTS) provides new research opportunities for work on non-model organisms, such as differential expression studies between populations exposed to different environmental conditions. However, such transcriptomic studies first require the production of a reference assembly. The choice of sampling procedure, sequencing strategy and assembly workflow is crucial. To develop a reliable reference transcriptome for Triatoma brasiliensis, the major Chagas disease vector in Northeastern Brazil, different de novo assembly protocols were generated using various datasets and software. Both 454 and Illumina sequencing technologies were applied on RNA extracted from antennae and mouthparts from single or pooled individuals. The 454 library yielded 278 Mb. Fifteen Illumina libraries were constructed and yielded nearly 360 million RNA-seq single reads and 46 million RNA-seq paired-end reads for nearly 45 Gb. For the 454 reads, we used three assemblers, Newbler, CAP3 and/or MIRA and for the Illumina reads, the Trinity assembler. Ten assembly workflows were compared using these programs separately or in combination. To compare the assemblies obtained, quantitative and qualitative criteria were used, including contig length, N50, contig number and the percentage of chimeric contigs. Completeness of the assemblies was estimated using the CEGMA pipeline. The best assembly (57,657 contigs, completeness of 80 %, < 1 % chimeric contigs) was a hybrid assembly leading to recommend the use of (1) a single individual with large representation of biological tissues, (2) merging both long reads and short paired-end Illumina reads, (3) several assemblers in order to combine the specific advantages of each.