14 resultados para piezocone

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents two case histories from Brazil where geophysical and resistivity piezocone tests were carried out to detect contamination. At the first one, the site investigation program was carried out to detect salt-water intrusions in a superficial sedimentary aquifer, at the Paranaguá harbor, in Paraná State. The second case history is a sanitary landfill from Bauru City, São Paulo State. In both sites, superficial geophysical tests were interpreted to detect and delineate the shape of contamination plume, helping to locate the resistivity piezocone tests. It was found that the interpretation of resistivity piezocone tests is straightforward to assess salt-water intrusion in sedimentary sands. For tropical soils, this technique presented some limitations since the groundwater table sometimes is deeper than the layer penetratable to the cone. Moreover, the genesis of those soils affects soil behavior and soil and water sampling is required to support interpretation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of piezocone tests with a slot filter filled with automotive grease for site characterization of tropical soils is assessed. Laboratory tests using the slot filter filled with automotive grease as well as the conventional porous piezo-element saturated with glycerin were carried out to evaluate the pore pressure (u 2) transducer response. CPTu tests using piezo-elements saturated with glycerin and the slot filter filled with grease were pushed side by side in different research sites in Brazil. Estimates of mechanical and hydraulic soil parameters were made based on pore pressure dissipation curves from using both techniques. Laboratory test results indicate that the pore pressure response using the slot filter with grease was delayed when compared to the piezo-element saturated with glycerin, since grease has a higher viscosity. For tropical soils, the records of u2 in piezocone tests using slot filter with grease presented larger peaks than with porous element saturated with glycerin. Records of u2 using the slot filter above the groundwater table suggest the increase of the degree of saturation in unsaturated zone, where porous filter can be desaturated by suction. The slot filter can be used to help the interpretation of the soil profile with deep groundwater level as well as to help detecting its position for some studied soils. The results shown high repeatability for all study sites. This technique is much easier to handle, especially for tropical soils, where the groundwater table is usually deep and pre-drilling is expensive and time consuming. © 2009 IOS Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A suit able decision-making on managing a contaminated site characterization program is strongly dependent of the diagnosis process. A detailed diagnosis can be done based on a Conceptual Site Model (CSM) elaboration using high resolution site characterization tools. The piezocone (CPTu) test is a high resolution tool which allows attaching several specific sensors, like the resistivity probe. This hybrid device is called the resistivity piezocone (RCPTu). A simulated geo-environmental site characterization program was performed on an erosion site using different tools (direct push tools soil samplers, hollow stem auger (HSA) drilling and RCPTu tests) to develop the CSM for a site similar to the Brazilian conditions. It was observed a good agreement between the site profiles interpreted by the different methods. The resistivity sensor attached to the piezocone improved the interpretation and the decision-making process on site was significantly better for the CSM elaboration. The RCPTu test data also allowed identifying the hydrogeological heterogeneities. The present study shows that the RCPTu test is also a useful and powerful tool to development an accurate CSM in a Brazilian condition, especially in an approach that prioritizes high resolution geo-environmental investigation. © 2013 Taylor & Francis Group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O ensaio de penetração do cone elétrico e do piezocone pertence a um grupo de ensaios de campo, cuja utilização vem sendo cada vez mais difundida. Tanto o avanço da eletrônica como a rápida evolução da informática têm proporcionado equipamentos mais apropriados, menores, mais robustos e mais econômicos, permitindo a incorporação de diversos sensores a essa ferramenta de investigação. Isto contribuiu para que esse ensaio se consagrasse para a descrição contínua do perfil geotécnico, a definição do nível de água e para estimativa de parâmetros mecânicos do solo. Neste artigo faz-se uma breve apresentação do piezocone e do minicone elétrico: o primeiro vem sendo utilizado nos últimos anos, especialmente em geotecnia ambiental, e o segundo, na investigação da infra-estrutura de transportes. Apresentam-se e discutem-se exemplos de emprego do piezocone para identificação de regiões do maciço contaminadas e do minicone para detectar a superfície de ruptura de uma seção de um talude de aterro, para avaliar sua estabilidade através de retroanálises. Concluise o trabalho fazendo-se algumas considerações sobre a utilização dessa tecnologia moderna e recente em solos tropicais que ocorrem no Brasil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different geoenvironmental site investigation techniques to assess contamination from a municipal solid waste disposal site in Brazil are presented here. Superficial geophysical investigation (geoelectrical survey), resistivity piezocone penetration tests (RCPTU), soil samples collected with direct-push samplers and water samples collected from monitoring wells were applied in this study. The application of the geoelectrical method was indispensable to identify the presence and flow direction of contamination plumes (leachate) as well as to indicate the most suitable locations for RCPTU tests and soil and water sampling. Chemical analyses of groundwater samples contributed to a better understanding of the flow of the contaminated plume. The piezocone presented some limitations for tropical soils, since the groundwater level is sometimes deeper than the layer which is impenetrable to the cone, and the soil genesis and unsaturated conditions affect soil behavior. The combined interpretation of geoelectrical measurements and soil and water samplings underpinned the interpretation of RCPTU tests. The interpretation of all the test results indicates that the contamination plume has already overreached the landfill's west-northwest borders. Geoenvironmental laboratory test results suggest that contamination from the solid waste disposal site has been developing gradually, indicating the need for continuous monitoring of the groundwater.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The University of British Columbia (UBC) began performing piezocone penetration tests (CPTU) with electrical resistivity measurements (RCPTU) in 1989. Since then, RCPTU research at UBC has focused on obtaining geo-environmental parameters such as fluid resistivity and soil engineering properties such as porosity and degree of saturation from measurements of bulk soil electrical resistivity using the empirical relationship proposed by Archie (1942). Within this framework, the paper illustrates and discusses important design and calibration issues for resistivity modules such as the use of isolated circuitry to achieve linear calibrations over large ranges of resistivity. The suitability of RCPTU measurements for determination of geo-environmental and geotechnical parameters are assessed using typical ranges of soil and groundwater properties and methods of isolating individual factors for study are discussed. Illustrative examples of RCPTU research efforts including the environmental characterization of mine tailings, delineation of saline water intrusions in fresh water aquifers and the quality control of geotechnical ground densification are presented throughout the text. It is shown that groundwater temperature and hence ion mobility is not significantly altered by frictional heat generated during piezocone penetration and that ratio-based approaches to monitoring soil porosity can be used to eliminate the requirement for extensive groundwater sampling programs. Lastly, it is shown that RCPTU measurements above the water table can only be made using resistivity modules that are stable over a large range of resistivities and that such measurements are the most difficult to interpret because of grain surface conduction effects and generally unknown fluid resistivities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A site investigation program was carried out to detect salt-water intrusions in a shallow sedimentary aquifer based on electrical resistivity measurements. The site is located close to Paranaguá harbor, in the Paraná State, Brasil. At this site, high chloride concentration contaminated shallow water wells used to supply water for local industries. The site investigation program included a fieldwork, dipole-dipole electrical profiling, resistivity piezocone tests, physical-chemical analysis of sampled water and interpretation of borehole logs. The resistivity piezocone tests provided two simultaneous information; the soil stratigraphy at a very detailed level and a quasi-continuous resistivity profile. Both information adequately complemented dipole-dipole electrical profiling test data. The integration of all test data allowed identifying the contaminated areas as well as guided the location of new water wells to be installed in this area.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A few traditional methods for determining water content in the field are either inaccurate or time consuming. As an alternative, the time domain reflectometry (TDR) technology has been used in the determination of the soil water content for geotechnical applications. This paper presents the preliminary results on the development of a new TDR probe for determining soil water content and dry density at different depths. This new probe is intended to be pushed into the ground using piezocone equipment. Different from the standard TDR probes with straight rods, the new probe consists of two parallel copper stripes coiled around a PVC-steel core. The probe diameter is the same as the standard 10 cm2 piezocone diameter. Through laboratory calibrations, it is possible to establish expressions relating the soil apparent dielectric constant and the bulk electrical conductivity with the gravimetric water content and the dry density. Copyright ASCE 2007.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a system for performing down-hole seismic test together with the piezocone test in order to determine the shear wave velocity (Vs) and for calculating the maximum shear modulus (Go); a basic parameter for analyzing the dynamic soil behavior and a reference value of the soil stiffness. The system components are described and tests results for checking the geophone response are also presented, both before and after installation into the probe. The system was used in down-hole tests carried out at three experimental research sites located in the interior of Sao Paulo State, Brazil, where in situ seismic test results are available. The Vs values measured in down-hole tests carried out with this system were consistent with those determined in cross-hole tests and with a commercial seismic piezocone, which enabled to validate the developed system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Cone Loading Test (CLT) consists of the execution of a load test on the piezocone probe in conjunction with the CPT test. The CLT yields the modulus ECLT, a parameter that can be used in the estimative of foundation settlement. It is also presented here the interpretation and the process to determine ECLT values from the stress-displacement curves obtained from cone loading tests. Several CLT tests were conducted at the experimental research site of São Paulo State University, Bauru-SP-Brazil. The geotechnical profile at the studied site is a brown to bright red slightly clayey fine sand, a tropical soil common to this region which is lateritic, unsaturated and collapsible. The results of CLT tests satisfactorily represent the behavior of the investigated soil. The penetrometric modulus ECLT for each depth was calculated considering the elastic behavior in the initial linear segment of the soil stress-strain curve. The ECLT moduli obtained for the various tests were compared to moduli obtained from PMT and DMT test results performed at same studied site. The shear modulus degradation curves obtained from the CLT tests are also presented. The comparison to PMT and DMT results indicates the CLT test is a viable complementary test to the CPT in the quest for better understanding stress-strain behavior of soils. Further, the CLT test provides a graphic visualization of the degradation of the shear modulus with increasing levels of strain. As a hybrid geotechnical test, CPT+CLT can be valuable in the investigation of non-conventional collapsible soils, whose literature lack reference parameters for the prediction of settlement in the design of foundations.