47 resultados para permeation tube
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
A dynamic system for stablishing a known standard gas mixture is necessary for many studies such as development and testing of analytical methods. A permeation tube can be used for this purpose. The work described here shows the construction, operation and calibration of a simple permeation tube which can be used to obtain large amounts of a standard gas.
Resumo:
Praziquantel has been shown to be highly effective against all known species of Schistosoma infecting humans. Spherical nanoparticles made of poly(D,L-lactide-co-glycolide) acid with controlled size were designed as drug carriers. Praziquantel, a hydrophobic drug, was entrapped into the polymeric nanoparticles with 30% (w/w) of theoretical loading. The nanoparticles size was approximately of 350 nm with 66% of encapsulation efficiency. The everted gut sac model shows to be efficient to evaluate the drug permeation through the intestinal membrane. The results show that free praziquantel presents 4-fold times more permeation than praziquantel-loaded PLGA nanoparticles and physical mixture. For this drug, in special, this result can be interesting, since the nanoparticulate system can behave as a drug reservoir and/or to have a more localized effect in intestinal membrane for a prolonged period of time, since great amounts of parasites can be usually found in the mesenteric veins.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Radial profiles are reported of average and rms temperature in a propane flame for the first, second, and third acoustic modes at four different axial positions above the burner in a Rijke-tube combustor. Selected plots of the power spectral density (PSD) of temperature fluctuations are also reported. These radial profiles are then compared to similar ones made in the same flame, but in the absence of the acoustic field. Visual observations and photographs of the flame showed a remarkable change in flame height and structure with the onset of acoustic oscillations. This reduction in flame length, caused by the enhanced mixing due to the acoustic velocity fluctuations, gave rise to higher and lower average and rms temperatures near or well above the burner, respectively. In general, the PSD plots had a broad frequency content. The general trend was a decrease in magnitude with an increase in frequency. All cases presented broad-band peaks at around 5 Hz related to the flame flickering phenomenon. Preferred frequencies were observed in the oscillating PSD plots related to the fundamental frequency as well as subharmonics in the tube. (C) 2000 Elsevier B.V. Ltd. All rights reserved.
Resumo:
A procedure for calculation of refrigerant mass flow rate is implemented in the distributed numerical model to simulate the flow in finned-tube coil dry-expansion evaporators, usually found in refrigeration and air-conditioning systems. Two-phase refrigerant flow inside the tubes is assumed to be one-dimensional, unsteady, and homogeneous. In themodel the effects of refrigerant pressure drop and the moisture condensation from the air flowing over the external surface of the tubes are considered. The results obtained are the distributions of refrigerant velocity, temperature and void fraction, tube-wall temperature, air temperature, and absolute humidity. The finite volume method is used to discretize the governing equations. Additionally, given the operation conditions and the geometric parameters, the model allows the calculation of the refrigerant mass flow rate. The value of mass flow rate is computed using the process of parameter estimation with the minimization method of Levenberg-Marquardt minimization. In order to validate the developed model, the obtained results using HFC-134a as a refrigerant are compared with available data from the literature.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Study Objectives: To study endotracheal tube (ETT) cuff pressures during nitrous oxide (N2O) anesthesia when the cuffs are inflated with air to achieve sealing pressure, and to evaluate the frequency of postoperative laryngotracheal complaints.Design: Prospective, randomized, blind study.Setting: Metropolitan teaching hospital.Patients: 50 ASA physical status I and II patients scheduled for elective abdominal surgery.Interventions: Patients received standard general anesthesia with 66% N2O in oxygen. In 25 patients, the ETT cuff was inflated with air to achieve a sealing pressure (P-seal group). In 25 patients, the ETT cuff was inflated with air to achieve a pressure of 25 cm H2O (P-25 group).Measurements and Main Results: ETT intracuff pressures were recorded before (control) and at 30, 60, 90, 120, and 150 minutes during N2O administration. We investigated the frequency and intensity of sore throat, hoarseness, and dysphagia in patients in the Post-Anesthesia Care Unit (PACU) and 24 hours following tracheal extubation. The cuff pressures in the P-seal group were significantly lower than in the P-25 group at all time points studied (p < 0.001), with a significant increase with time in both groups (p < 0.001). The cuff pressures exceeded the critical pressure of 30 cm H2O only after 90 minutes in the P-seal group and already by 30 minutes in the P-25 group. The frequency and intensity of sore throat, hoarseness, and dysphagia were similar in both groups in the PACU and 24 hours after tracheal extubation (p > 0.05).Conclusions: Minimum ETT sealing cuff pressure during N2O anesthesia did not prevent, but instead attenuated, the increase in cuff pressure and did not decrease postoperative laryngotracheal complaints. (C) 2004 by Elsevier B.V.
Resumo:
CONTEXTO E OBJETIVO: Os tubos traqueais são dispositivos utilizados para manutenção da ventilação. A hiperinsuflação do balonete do tubo traqueal, causada pela difusão do óxido nitroso (N2O), pode determinar lesões traqueais, que se manifestam clinicamente como odinofagia, rouquidão e tosse. A lidocaína, quando injetada no balonete do tubo traqueal, difunde-se através de sua parede, determinando ação anestésica local na traquéia. O objetivo foi avaliar a efetividade e a segurança do balonete do tubo traqueal preenchido com ar comparado com o balonete preenchido com lidocaína, considerando os desfechos: sintomas cardiovasculatórios (HAS, taquicardia); odinofagia, tosse, rouquidão e tolerância ao tubo traqueal. TIPO DE ESTUDO E LOCAL: Estudo clínico prospectivo, realizado no Departamento de Anestesiologia da Faculdade de Medicina da Unesp, campus de Botucatu. MÉTODOS: A pressão do balonete do tubo traqueal foi medida, entre 50 pacientes, antes, 30, 60, 90 e 120 minutos após o início da inalação de N2O anestésico. As pacientes foram distribuídas aleatoriamente em dois grupos: Air, em que o balonete foi inflado com ar para obtenção de pressão de 20 cm H2O, e Lido, em que o balonete foi preenchido com lidocaína a 2% mais bicarbonato de sódio a 8,4% para obtenção da mesma pressão. O desconforto antes da extubação, e manifestações clínicas como dor de garganta, rouquidão e tosse foram registrados no momento da alta da unidade de cuidados pós-anestésicos, e dor de garganta e rouquidão foram avaliadas também 24 horas após a anestesia. RESULTADOS: Os valores da pressão no balonete em G2 foram significativamente menores do que os de Air em todos os tempos de estudo, a partir de 30 minutos (p < 0,001). A proporção de pacientes que reagiu ao tubo traqueal no momento da desintubação foi significantemente menor em Lido (p < 0,005). A incidência de odinofagia foi significantemente menor em Lido no primeiro dia de pós-operatório (p < 0,05). A incidência de tosse e rouquidão não diferiu entre os grupos. CONCLUSÕES: Durante ventilação artificial, empregando-se a mistura de oxigênio e N2O, a insuflação do balonete com lidocaína 2% alcalinizada impede que ocorra aumento significante da pressão no balonete e determina maior tolerância ao tubo traqueal e menor incidência de odinofagia no pós-operatório, podendo então ser considerada mais segura e com maior efetividade.
Resumo:
BACKGROUND: To physiologically reconstruct the biliary tract, Crema et al suggested the application of the Monti principle to the biliary tract, already used in humans for the urinary tract. With this technique, a jejunal segment is transversely retubularized. This study aimed to evaluate the efficacy of jejunal tube interposition between the common bile duct and duodenum in dogs.METHODS: Thirteen dogs underwent a laparoscopic common bile duct ligature, followed by a biliodigestive connection by jejunal tube interposition after one week. The levels of glutamic-pyruvic and glutamic-oxalacetic transaminases, total bilirubins, alkaline phosphatase and gamma-glutamyltransferase were assessed before surgery and thereafter weekly until euthanasia, which was performed 6 weeks after biliodigestive connection.RESULTS: Data on 9 dogs were analyzed statistically. The dogs presented with obstructive jaundice after common bile duct ligature, as confirmed by biochemical examination. They showed a statistically significant reduction in cholestasis after biliodigestive connection by jejunal tube interposition and were healthy until the end of the experiment.CONCLUSION: A statistically significant reduction was seen in total bilirubin and canalicular enzymes (alkaline phosphatase and gamma-glutamyltransferase) in the 9 dogs 6 weeks after biliodigestive conviction by jejunal tube interposition.
Resumo:
The ultrastructural features and the plastid changes caused by sample preparation were studied in sieve elements of Panicum maximum leaves. Samples of expanded leaves, taken near the ligule region, were fixed and processed by common light and transmission electron microscopy methods. In mature sieve-tube elements, the protoplast is electron-translucent and plastids are the most frequent organelles. Mitochondria and smooth endoplasmic reticulum segments are also visible and occupy a parietal position within the cell. The plastids are globular and show electron-dense proteinaceous inclusions in the stroma. The protein crystals are predominantly cuneate, but thin crystalloids and amorphous and/or filamentous proteins also occur. The presence of intact plastids plus others in different phases of plastid envelope rupture were interpreted as evidence that this rupture is a normal event in response to injury. This plastid envelope rupture is possibly activated by the release of pressure in the sieve-tube element. After plastid membrane vesiculation, the stroma and the protein crystals are dispersed within the sieve-element ground cytoplasm. The vesicles originating from the plastid envelope move to one cell pole, while protein crystalloids move to the opposite pole and agglomerate in the sieve-plate region. Our findings indicate that these protein crystalloids, which deposit in the sieve plate, may act in sieve-plate pores occlusion, preventing the release of phloem sap, similar to the role of P-protein in dicotyledons. (c) 2008 Elsevier GmbH. All rights reserved.